Inductive sensor NCN50-FP-N0-P4-V1
Technical Data
General specifications
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance sn50 mm
Installation non-flush
Assured operating distance sa0 ... 40.5 mm
0102
Model Number
NCN50-FP-N0-P4-V1
Features
• 50 mm non-flush
Accessories
V1-G
Female connector, M12, 4-pin, field attachable
V1-W
Female connector, M12, 4-pin, field attachable
V1-G-N-2M-PUR
Female cordset, M12, 2-pin, NAMUR, PUR cable
V1-W-N-2M-PUR
Female cordset, M12, 2-pin, NAMUR, PUR cable
Actual operating distance s
Reduction factor rAl 0.4
Reduction factor r
Reduction factor r
Output type 2-wire
Nominal ratings
Installation conditions
A
B
F
Nominal voltage U
Switching frequency f 0 ... 80 Hz
Hysteresis H 0 ... 5 typ. 3 %
Reverse polarity protection reverse polarity protected
Short-circuit protection yes
Current consumption
Measuring plate not detected
Measuring plate detected
Time delay before availability t
Switching state indicator LED, yellow
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Storage temperature -40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin
Housing material PBT/metal
Sensing face PBT
Degree of protection IP67
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and
directives
Standard conformity
NAMUR
Electromagnetic compatibility
Standards
Approvals and certificates
FM approval
Control drawing
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
0.35
Cu
0.8
304
Dimensions
45 ... 55 mm typ.
r
40 mm
150 mm
240 mm
8.2 V (Ri approx. 1 kΩ)
o
≥ 3 mA
≤ 1 mA
≤ 20 ms
v
1G; 2G; 1D
EN 60947-5-6:2000
IEC 60947-5-6:1999
NE 21:2007
EN 60947-5-2:2007
IEC 60947-5-2:2007
116-0165
80
Release date: 2017-07-25 13:33 Date of issue: 2017-07-25 184679_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
40
7
LED
M12 x 1
9 16
Ø 5.3
65
65
1

Inductive sensor NCN50-FP-N0-P4-V1
Electrical Connection
1
2
L+
L-
Wire colors in accordance with EN 60947-5-6
1 BN
2 BU
Equipment protection level Ga
CE marking 0102
Effective internal inductivity C
Effective internal inductance L
Highest permissible ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
Equipment protection level Gb
CE marking 0102
i
i
(brown)
(blue)
≤ 220 nF ; a cable length of 10 m is considered.
≤ 360 µH ; a cable length of 10 m is considered.
temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already
Note:
been applied to the temperature table for category 1.
Effective internal inductivity C
Effective internal inductance L
Maximum permissible ambient temperature T
Equipment protection level Da
CE marking 0102
Effective internal inductivity C
Effective internal inductance L
i
i
i
i
≤ 220 nF ; a cable length of 10 m is considered.
≤ 360 µH ; a cable length of 10 m is considered.
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
amb
temperature class, and the effective internal reactance values can be found on the EU-type examination certificate.
≤ 220 nF ; a cable length of 10 m is considered.
≤ 360 µH ; a cable length of 10 m is considered.
Release date: 2017-07-25 13:33 Date of issue: 2017-07-25 184679_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2