General specifications
Switching function 2 x normally closed (NC) Output type NAMUR Rated operating distance sn3 mm Installation flush mountable Assured operating distance sa0 ... 2.4 mm
0102
Model Number
NCN3-F31K-N4-S
Features
• Compact and stable housing with terminal compartment connection
• Fixed setting
• EC-Type Examination Certificate TÜV99 ATEX 1479X
•Screw terminals
• Usable up to SIL 2 acc. to IEC 61508
Accessories
BT65A
Activator for F31 series
BT65X
Activator for F31 series
BT115A
Activator for F31 series
BT115X
Activator for F31 series
BT65B
Activator for F31 series
BT115B
Activator for F31 series
Actual operating distance s Actuating element Stainless steel 1.4305 / AISI 303
Reduction factor r Reduction factor rCu 0.4 Reduction factor r Reduction factor r Reduction factor r Output type 2-wire
Nominal ratings
Nominal voltage Uo8 V Switching frequency f 0 ... 3 kHz Hysteresis H typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Suitable for 2:1 technology yes , Reverse polarity protection diode not required Current consumption
Measuring plate not detected
Measuring plate detected Time delay before availability t Switching state indicator LED, yellow
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2 MTTF
1470 a
d
Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F) Storage temperature -40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection (system side) Screw terminals, tightening torque min. 0.5 Nm
Core cross-section (system side) rigid: 0.14 ... 2.5 mm
Housing material PBT Sensing face PBT Degree of protection IP67 Tightening torque, housing screws 1 Nm Tightening torque, cable gland M20 x 1.5 ; 7 Nm
General information
Use in the hazardous area see instruction manuals
Compliance with standards and directives
Standard conformity
NAMUR
Electromagnetic compatibility
Standards
Approvals and certificates
EAC conformity TR CU 012/2011 UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
0.5
Al
1
304
1.3
St37
0.6
Brass
2.7 ... 3.3 mm typ.
r
8.5 mm x 8.5 mm x 0.5 mm
3 mA 1 mA 1.1 ms
v
Stripped length 7 mm
2
flexible: 0.14 ... 1.5 mm flexible with core-end sleeve: 0.25 ... 1.5 mm
EN 60947-5-6:2000 IEC 60947-5-6:1999 NE 21:2007 EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
2
2
Release date: 2018-04-19 08:15 Date of issue: 2018-04-19 223953_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive sensor NCN3-F31K-N4-S
Dimensions
65
I
40
Electrical Connection
35
77.5
95
7
N4
II
5.4
9
M20 x 1.5
11
14
S
LED
30
S
4
I
5 1
II
2
I
I
II
+
­+
-
Release date: 2018-04-19 08:15 Date of issue: 2018-04-19 223953_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Loading...
+ 3 hidden pages