Inductive sensor |
NCB5-18GM40-Z1-V1 |
|
|
|
|
|
|
|
|
Model Number
NCB5-18GM40-Z1-V1
Features
•Comfort series
•5 mm flush
•2-wire DC
Connection
1 |
|
|
|
L+ |
2 |
|
|
|
|
|
|
|
L- |
|
|
||||
|
|
|
|
|
|
|
|
|
|
Pinout
1
2 4
3
Wire colors in accordance with EN 60947-5-2
<![if ! IE]> <![endif]>_eng.xml |
1 |
|
BN |
(brown) |
|
|
|
||||
|
2 |
|
WH |
(white) |
|
<![if ! IE]> <![endif]>089263 |
3 |
|
BU |
(blue) |
|
4 |
|
BK |
(black) |
||
<![if ! IE]> <![endif]>2012-06-15 |
|
|
|
|
|
<![if ! IE]> <![endif]>issue: |
Accessories |
|
|||
<![if ! IE]> <![endif]>of |
V1-W |
|
|
|
|
<![if ! IE]> <![endif]>Date |
|
|
|
||
4-pin, M12 female field-attachable connector |
|||||
<![if ! IE]> <![endif]>07:58 |
V1-G |
|
|
|
|
4-pin, M12 female field-attachable connector |
|||||
|
|||||
<![if ! IE]> <![endif]>15 |
V1-W-2M-PUR |
|
|||
Cable socket, M12, 4-pin, PUR cable |
|||||
<![if ! IE]> <![endif]>-06- |
|||||
EXG-18 |
|
|
|
||
<![if ! IE]> <![endif]>2012 |
|
|
|
||
Quick mounting bracket with dead stop |
|||||
<![if ! IE]> <![endif]>date: |
BF 18 |
|
|
|
|
Mounting flange, 18 mm |
|
||||
<![if ! IE]> <![endif]>Release |
V1-G-2M-PUR |
|
|||
|
|
Cable socket, M12, 4-pin, PUR cable
Dimensions
|
M18x1 |
|
<![if ! IE]> <![endif]>4 |
|
|
|
<![if ! IE]> <![endif]>40 |
<![if ! IE]> <![endif]>45 |
24 |
|
<![if ! IE]> <![endif]>55 |
S |
|
|
LED |
<![if ! IE]> <![endif]>6 |
|
M12x1 |
|
|
Technical Data
General specifications |
|
|
|
Switching element function |
|
DC |
NC |
Rated operating distance |
sn |
5 mm |
|
Installation |
|
flush |
|
Output polarity |
|
DC |
|
Assured operating distance |
sa |
0 ... 4.05 mm |
|
Reduction factor rAl |
|
0.37 |
|
Reduction factor rCu |
|
0.33 |
|
Reduction factor r304 |
|
0.7 |
|
Nominal ratings |
|
|
|
Operating voltage |
UB |
5 ... 60 V |
|
Switching frequency |
f |
0 ... 350 Hz |
|
Hysteresis |
H |
1 ... 10 |
typ. 5 % |
Reverse polarity protected |
|
tolerant |
|
Short-circuit protection |
|
pulsing |
|
Voltage drop |
Ud |
≤ 5 V |
|
Operating current |
IL |
2 ... 100 mA |
|
Lowest operating current |
Im |
2 mA |
|
Off-state current |
Ir |
0 ... 0.5 mA typ. |
|
Indication of the switching state |
|
Multihole-LED, yellow |
|
Functional safety related parameters |
|
|
|
|
|
|
|
MTTFd |
|
1730 a |
|
Mission Time (TM) |
|
20 a |
|
Diagnostic Coverage (DC) |
|
0 % |
|
Ambient conditions |
|
|
|
|
|
|
|
Ambient temperature |
|
-25 ... 70 °C (-13 ... 158 °F) |
|
Mechanical specifications |
|
|
|
|
|
|
|
Connection type |
|
Device connector M12 x 1 , 4-pin |
|
Housing material |
|
Stainless steel 1.4305 / AISI 303 |
|
Sensing face |
|
PBT |
|
Protection degree |
|
IP67 |
|
Compliance with standards and directives |
|
|
|
|
|
|
|
Standard conformity |
|
|
|
Standards |
|
EN 60947-5-2:2007 |
|
|
|
IEC 60947-5-2:2007 |
|
|
|
|
|
Approvals and certificates |
|
|
|
|
|
|
|
UL approval |
|
cULus Listed, General Purpose |
|
CSA approval |
|
cCSAus Listed, General Purpose |
|
|
|
|
|
CCC approval |
|
Certified by China Compulsory Certification (CCC) |
|
|
|
|
|
Subject to modifications without notice |
Copyright Pepperl+Fuchs |
1