Pepperl Fuchs NCB50-FP-E34-C-P3-V1 Data Sheet

Inductive sensor NCB50-FP-E34-C-P3-V1
Dimensions
Model Number
NCB50-FP-E34-C-P3-V1
Features
•4-wire DC
• Weld Immune
• Optimum use at a distance >50 cm
Connection
1
4
3
L+
L-
Pinout
1
2
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK
(brown) (white) (blue) (black)
4
3
15
40
M12 x 1
10 22
84
65
65
LEDs
Technical Data
General specifications
Switching element function PNP NC Rated operating distance s Installation flush Output polarity DC Assured operating distance sa0 ... 40.5 mm Reduction factor r Reduction factor rCu 0.35 Reduction factor r
Nominal ratings
Operating voltage UB10 ... 60 V DC Switching frequency f 0 ... 1 Hz Hysteresis H typ. 3 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop Ud≤ 3 V Operating current I Off-state current I No-load supply current I Time delay before availability t Tuning-out 50 ms Operating voltage display LED, green Switching state indication LED, yellow
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin Housing material PBT/metal Sensing face PBT, active surface PTFE coated Housing base metal Protection degree IP68 Mass 530 g
Compliance with standards and directives
Standard conformity
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose
0.38
Al
0.83
304
50 mm
n
0 ... 200 mA
L
0 ... 0.5 mA
r
20 mA
0
1 s
v
EN 60947-5-2:2007 IEC 60947-5-2:2007
ø 9.5
7
ø 5.3
Release date: 2013-04-05 16:37 Date of issue: 2013-04-08 188778_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
1
Inductive sensor NCB50-FP-E34-C-P3-V1
Installation hint
These sensors are especially designed for embeddable mounting in conveyor floors. Due to its precise location in metal base plates the sensor is afforded a high degree of mechanical protection. No clearance is required between the sensor and the base plate, avoiding the need for protective guarding to prevent possible foot injury.
The large sensing range ensures positive detection, and thus provides consistent control and monitoring of the conveyor.
>95mm
Warning! Once the metal screening has been removed, the sensor can no longer be
mounted.embeddable
Release date: 2013-04-05 16:37 Date of issue: 2013-04-08 188778_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
2
Loading...