Pepperl Fuchs NCB50-FP-E34-C-P3-V1 Data Sheet

Pepperl Fuchs NCB50-FP-E34-C-P3-V1 Data Sheet

Inductive sensor

Model Number

NCB50-FP-E34-C-P3-V1

Features

50 mm flush

4-wire DC

Weld Immune

Optimum use at a distance >50 cm

Connection

1

L+

4

3

L-

Pinout

1

2 4

3

<![if ! IE]>

<![endif]>eng.xml

Wire colors in accordance with EN 60947-5-2

1

 

BN

(brown)

 

 

<![if ! IE]>

<![endif]>188778

2

 

WH

(white)

4

 

BK

(black)

 

3

 

BU

(blue)

<![if ! IE]>

<![endif]>2013-04-08

 

 

 

 

<![if ! IE]>

<![endif]>Date of issue:

 

 

 

 

<![if ! IE]>

<![endif]>-04-05 16:37

 

 

 

 

<![if ! IE]>

<![endif]>Release date: 2013

 

 

 

 

Subject to modifications without notice

 

NCB50-FP-E34-C-P3-V1

Dimensions

 

<![if ! IE]>

<![endif]>15

ø 9.5

 

<![if ! IE]>

<![endif]>40

 

 

M12 x 1

<![if ! IE]>

<![endif]>22

<![if ! IE]>

<![endif]>7

<![if ! IE]>

<![endif]>10

ø 5.3

 

<![if ! IE]>

<![endif]>84

<![if ! IE]>

<![endif]>65

 

 

65

 

 

LEDs

 

 

 

 

 

 

 

 

Technical Data

 

 

 

 

General specifications

 

 

 

 

 

 

 

 

 

 

Switching element function

 

PNP

 

NC

Rated operating distance

sn

50 mm

Installation

 

flush

 

 

Output polarity

 

DC

 

 

Assured operating distance

sa

0 ... 40.5 mm

Reduction factor rAl

 

0.38

 

 

Reduction factor rCu

 

0.35

 

 

Reduction factor r304

 

0.83

 

 

Nominal ratings

 

 

 

 

Operating voltage

UB

10 ... 60 V DC

Switching frequency

f

0 ... 1 Hz

Hysteresis

H

typ. 3

%

Reverse polarity protection

 

reverse polarity protected

Short-circuit protection

 

pulsing

Voltage drop

Ud

3 V

 

 

Operating current

IL

0 ... 200 mA

Off-state current

Ir

0 ... 0.5 mA

No-load supply current

I0

20 mA

Time delay before availability

tv

1 s

 

 

Tuning-out

 

50 ms

Operating voltage display

 

LED, green

Switching state indication

 

LED, yellow

Ambient conditions

 

 

 

 

Ambient temperature

 

-25 ... 70 °C (-13 ... 158 °F)

Mechanical specifications

 

 

 

 

Connection type

 

Connector M12 x 1 , 4-pin

Housing material

 

PBT/metal

Sensing face

 

PBT, active surface PTFE coated

Housing base

 

metal

 

 

Protection degree

 

IP68

 

 

Mass

 

530 g

 

 

Compliance with standards and directives

 

 

 

 

 

 

 

 

 

Standard conformity

 

 

 

 

Standards

 

EN 60947-5-2:2007

 

 

 

IEC 60947-5-2:2007

 

 

 

 

 

 

Approvals and certificates

 

 

 

 

 

 

 

 

 

UL approval

 

cULus Listed, General Purpose

CSA approval

 

cCSAus Listed, General Purpose

 

 

 

 

 

 

Copyright Pepperl+Fuchs

1

 

 

 

 

 

 

Inductive sensor

NCB50-FP-E34-C-P3-V1

 

 

 

 

Installation hint

These sensors are especially designed for embeddable mounting in conveyor floors. Due to its precise location in metal base plates the sensor is afforded a high degree of mechanical protection. No clearance is required between the sensor and the base plate, avoiding the need for protective guarding to prevent possible foot injury.

The large sensing range ensures positive detection, and thus provides consistent control and monitoring of the conveyor.

mm > 95

Warning!

Once the metal screening has been removed, the sensor can no longer be embeddable mounted.

<![if ! IE]>

<![endif]>Release date: 2013-04-05 16:37 Date of issue: 2013-04-08 188778_eng.xml

Subject to modifications without notice

Copyright Pepperl+Fuchs