Inductive sensor NCB50-FP-E2-P1-V1-3G-3D
Technical Data
General specifications
Switching function Normally open (NO)
Output type PNP
Rated operating distance sn50 mm
Installation flush
Output polarity DC
Model Number
NCB50-FP-E2-P1-V1-3G-3D
Features
• 50 mm flush
•3-wire DC
Assured operating distance s
Reduction factor rAl 0.38
Reduction factor r
Reduction factor r
Output type 3-wire
Nominal ratings
Operating voltage UB10 ... 60 V DC
Switching frequency f 0 ... 80 Hz
Hysteresis H typ. 3 %
Reverse polarity protection reverse polarity protected
Voltage drop U
Operating current I
S
Off-state current I
No-load supply current I
Time delay before availability t
Operating voltage indicator LED, green
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 960 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 4-pin
Housing material PBT
Sensing face PBT
Housing base PBT
Degree of protection IP67
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and
directives
Standard conformity
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval Certified by China Compulsory Certification (CCC)
Cu
304
Dimensions
0.35
0.83
0 ... 40.5 mm
a
≤ 3 V
d
0 ... 200 mA
L
0 ... 0.5 mA
r
≤ 20 mA
0
≤ 30 ms
v
3G; 3D
EN 60947-5-2:2007
IEC 60947-5-2:2007
15
ø 9.5
40
M12 x 1
7
916
84
80
65
65
LEDs
ø 5.3
Release date: 2016-11-07 10:02 Date of issue: 2018-02-19 129867_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Inductive sensor NCB50-FP-E2-P1-V1-3G-3D
Electrical Connection
Pinout
1
4
3
Wire colors in accordance with EN 60947-5-2
1 BN
2 WH
3 BU
4 BK
2
L+
L-
1
4
3
(brown)
(white)
(blue)
(black)
Installation Hint
These sensors are especially
designed for embeddable mounting in
conveyor floors. Due to its precise
location in metal base plates the
sensor is afforded a high degree of
mechanical protection. No clearance
is required between the sensor and
the base plate, avoiding the need for
protective guarding to prevent
possible foot injury.
The large sensing range ensures
positive detection, and thus provides
consistent control and monitoring of
the conveyor.
>95mm
Warning!
Once the metal screening has been
removed, the sensor can no longer be
Equipment protection level Gc (nA)
CE marking
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
mounted.embeddable
Release date: 2016-11-07 10:02 Date of issue: 2018-02-19 129867_eng.xml

Inductive sensor NCB50-FP-E2-P1-V1-3G-3D
ATEX marking ¬ II 3G Ex nA IIC T6 X
Standards EN 60079-0:2006, EN 60079-15:2005
Special conditions
Maximum operating current IL
Maximum operating voltage U
Bmax
Maximum permissible ambient temperature T
at U
at U
at U
at U
at U
at U
=60 V, IL=200 mA
Bmax
=60 V, IL=100 mA
Bmax
=60 V, IL=25 mA
Bmax
=30 V, IL=200 mA
Bmax
=30 V, IL=100 mA
Bmax
=30 V, IL=50 mA
Bmax
Equipment protection level Dc
CE marking
ATEX marking ¬ II 3D IP67 T 95 °C (203 °F) X
Standards EN 50281-1-1
Special conditions
Maximum heating (Temperature rise)
at U
at U
at U
at U
at U
at U
=60 V, IL=200 mA
Bmax
=60 V, IL=100 mA
Bmax
=60 V, IL=25 mA
Bmax
=30 V, IL=200 mA
Bmax
=30 V, IL=100 mA
Bmax
=30 V, IL=50 mA
Bmax
Equipment protection level Dc (tD)
General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.
Special conditions
Maximum permissible ambient temperature T
at U
at U
at U
at U
at U
at U
=60 V, IL=200 mA
Bmax
=60 V, IL=100 mA
Bmax
=60 V, IL=25 mA
Bmax
=30 V, IL=200 mA
Bmax
=30 V, IL=100 mA
Bmax
=30 V, IL=50 mA
Bmax
Ignition protection category "n"
Use is restricted to the following stated conditions
The maximum permissible load current must be restricted to the values given in the following list. High load currents
and load short-circuits are not permitted.
The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are
not permissible.
dependant of the load current IL and the max. operating voltage U
Umax
Information can be taken from the following list.
Bmax
44 °C (111.2 °F)
45 °C (113 °F)
47 °C (116.6 °F)
50 °C (122 °F)
53 °C (127.4 °F)
56 °C (132.8 °F)
Protection via housing
Use is restricted to the following stated conditions
dependant of the load current IL and the max. operating voltage U
Information can be taken from the following list. The maximum surface temperature at maximum ambient
temperature is given in the Ex identification of the apparatus.
Bmax
25 K
24 K
22 K
19 K
16 K
14 K
The maximum surface temperature has been determined in accordance with method A without a dust layer on the
equipment.
The data stated in the data sheet are restricted by this operating instruction!
The special conditions must be adhered to!
dependant of the load current IL and the max. operating voltage U
Umax
Information can be taken from the following list.
Bmax
44 °C (111.2 °F)
45 °C (113 °F)
47 °C (116.6 °F)
50 °C (122 °F)
53 °C (127.4 °F)
56 °C (132.8 °F)
Release date: 2016-11-07 10:02 Date of issue: 2018-02-19 129867_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3