Pepperl Fuchs NCB50-FP-A2-P4 Data Sheet

Inductive sensor NCB50-FP-A2-P4
Dimensions
Model Number
NCB50-FP-A2-P4
Features
•4-wire DC
• Surface mount
Connection
1
4
2
3
15
ø 9.5
40
1/2“ NPT
7
S
10
84
80
65
65
LEDs
ø 5.3
Technical Data
L+
L-
General specifications
Switching element function PNP NO/NC Rated operating distance s Installation flush Output polarity DC Assured operating distance sa0 ... 40.5 mm Reduction factor r Reduction factor rCu 0.35 Reduction factor r
Nominal ratings
Operating voltage UB10 ... 60 V DC Switching frequency f 0 ... 80 Hz Hysteresis H typ. 3 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop Ud≤ 3 V Operating current I Off-state current I No-load supply current I Time delay before availability t Operating voltage display LED, green Switching state indication LED, yellow
Functional safety related parameters
MTTFd 680 a Mission Time (T Diagnostic Coverage (DC) 0 %
Standard conformity
Standards EN 60947-5-2:2007
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type screw terminals Core cross-section up to 2.5 mm Housing material PBT/metal Sensing face PBT Housing base metal Protection degree IP68
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval Certified by China Compulsory Certification (CCC)
0.38
Al
0.83
304
) 20 a
M
50 mm
n
0 ... 200 mA
L
0 ... 0.5 mA
r
20 mA
0
300 ms
v
IEC 60947-5-2:2007
2
Release date: 2013-04-17 16:14 Date of issue: 2013-04-17 910960_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive sensor NCB50-FP-A2-P4
Installation hint
These sensors are especially designed for embeddable mounting in conveyor floors. Due to its precise location in metal base plates the sensor is afforded a high degree of mechanical protection. No clearance is required between the sensor and the base plate, avoiding the need for protective guarding to prevent possible foot injury.
The large sensing range ensures positive detection, and thus provides consistent control and monitoring of the conveyor.
>95mm
Warning! Once the metal screening has been removed, the sensor can no longer be
mounted.embeddable