Inductive sensor NCB40-FP-A2-P4
Dimensions
ø 9.5
LEDs
40
1/2“ NPT
7
Model Number
NCB40-FP-A2-P4
Features
•4-wire DC
• 40 mm flush
Connection
1
4
2
3
S
L+
L-
Technical Data
General specifications
Switching element function PNP NO/NC
Rated operating distance s
Installation flush
Output polarity DC
Assured operating distance sa0 ... 32.4 mm
Reduction factor r
Reduction factor rCu 0.23
Reduction factor r
Nominal ratings
Operating voltage UB10 ... 60 V DC
Switching frequency f 0 ... 80 Hz
Hysteresis H 3 ... 15 % 5 % typical
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Voltage drop Ud≤ 3 V
Operating current I
Off-state current I
No-load supply current I
Time delay before availability t
Operating voltage display LED, green
Switching state indication LED, yellow
Functional safety related parameters
MTTFd 680 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type screw terminals
Core cross-section up to 2.5 mm
Housing material PBT
Sensing face PBT
Housing base metal
Protection degree IP68
Compliance with standards and directives
Standard conformity
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval Certified by China Compulsory Certification (CCC)
80
Standards
11
65
0.25
Al
0.85
304
) 20 a
M
65
40 mm
n
0 ... 200 mA
L
0 ... 0.5 mA
r
≤ 20 mA
0
≤ 300 ms
v
EN 60947-5-2:2007
IEC 60947-5-2:2007
LEDs
2
ø 5.3
Release date: 2013-04-09 11:30 Date of issue: 2013-04-09 908802_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
1
Inductive sensor NCB40-FP-A2-P4
Installation hint
These sensors are especially
designed for embeddable mounting in
conveyor floors. Due to its precise
location in metal base plates the
sensor is afforded a high degree of
mechanical protection. No clearance
is required between the sensor and
the base plate, avoiding the need for
protective guarding to prevent
possible foot injury.
The large sensing range ensures
positive detection, and thus provides
consistent control and monitoring of
the conveyor.
Release date: 2013-04-09 11:30 Date of issue: 2013-04-09 908802_eng.xml