Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance sn10 mm
Installation flush
Assured operating distance sa0 ... 8.1 mm
0102
Model Number
NCB10-30GM40-N0-15M-OG
Features
• 10 mm flush
• Shielded PUR cable for oil and gas
sector
Accessories
BF 30
Mounting flange, 30 mm
Actual operating distance s
Reduction factor rAl 0.32
Reduction factor r
Reduction factor r
Output type 3-wire
Nominal ratings
Nominal voltage Uo8 V
Switching frequency f0 ... 650 Hz
Hysteresis H1 ... 10 typ. 5 %
Reverse polarity protection reverse polarity protected
Short-circuit protection yes
Suitable for 2:1 technology yes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected
Measuring plate detected
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 1870 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 80 °C (-13 ... 176 °F)
Storage temperature -40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Connection type cable PUR (halogen-free) , 15 m , screened , Oil resistant , Flame-
Core cross-section 2x 0.5 mm
Housing material Stainless steel 1.4305 / AISI 303
Sensing face PBT
Degree of protection IP66 / IP67
Cable
Bending radius
Note The shield is not connected to the sensor.
General information
Use in the hazardous area see instruction manuals
Compliance with standards and
directives
Standard conformity
NAMUR
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
0.32
Cu
0.72
304
) 20 a
M
Dimensions
9 ... 11 mm typ.
r
≥ 3 mA
≤ 1 mA
retardant as per IEC 60332-1
> 7.5 x cable diameter
EN 60947-5-6:2000
IEC 60947-5-6:1999
EN 60947-5-2:2007
IEC 60947-5-2:2007
2
Release date: 2017-10-11 16:16 Date of issue: 2017-10-11 232395_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
M30x1,5
LED
37
40
5
36
1
Inductive sensorNCB10-30GM40-N0-15M-OG
Electrical Connection
1
2
L+
L-
Release date: 2017-10-11 16:16 Date of issue: 2017-10-11 232395_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Inductive sensorNCB10-30GM40-N0-15M-OG
Data for application in connection with hazardous
areas
Equipment protection level Ga , Gb , Gc (ic) , Da , Mb
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
= 16 V , Ii = 25 mA , Pi = 34 mW ,
at U
i
T6 : 59 °C (138.2 °F)
T5 : 71 °C (159.8 °F)
T4 : 99 °C (210.2 °F)
T3 : 99 °C (210.2 °F)
T2 : 99 °C (210.2 °F)
T1 : 99 °C (210.2 °F)
at U
= 16 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 56 °C (132.8 °F)
T5 : 68 °C (154.4 °F)
T4 : 96 °C (204.8 °F)
T3 : 96 °C (204.8 °F)
T2 : 96 °C (204.8 °F)
T1 : 96 °C (204.8 °F)
at U
= 16 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 45 °C (113 °F)
T5 : 57 °C (134.6 °F)
T4 : 81 °C (177.8 °F)
T3 : 81 °C (177.8 °F)
T2 : 81 °C (177.8 °F)
T1 : 81 °C (177.8 °F)
at U
= 16 V , Ii = 76 mA , Pi = 242 mW ,
i
T6 : 37 °C (98.6 °F)
T5 : 49 °C (120.2 °F)
T4 : 63 °C (145.4 °F)
T3 : 63 °C (145.4 °F)
T2 : 63 °C (145.4 °F)
T1 : 63 °C (145.4 °F)
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 59 °C (138.2 °F)
T5 : 71 °C (159.8 °F)
T4 : 99 °C (210.2 °F)
T3 : 99 °C (210.2 °F)
T2 : 99 °C (210.2 °F)
T1 : 99 °C (210.2 °F)
at U
= 16 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 56 °C (132.8 °F)
T5 : 68 °C (154.4 °F)
T4 : 96 °C (204.8 °F)
T3 : 96 °C (204.8 °F)
T2 : 96 °C (204.8 °F)
T1 : 96 °C (204.8 °F)
at U
= 16 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 45 °C (113 °F)
T5 : 57 °C (134.6 °F)
T4 : 81 °C (177.8 °F)
T3 : 81 °C (177.8 °F)
T2 : 81 °C (177.8 °F)
T1 : 81 °C (177.8 °F)
at U
= 16 V , Ii = 76 mA , Pi = 242 mW ,
i
T6 : 37 °C (98.6 °F)
T5 : 49 °C (120.2 °F)
T4 : 63 °C (145.4 °F)
T3 : 63 °C (145.4 °F)
T2 : 63 °C (145.4 °F)
T1 : 63 °C (145.4 °F)
Release date: 2017-10-11 16:16 Date of issue: 2017-10-11 232395_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3
Inductive sensorNCB10-30GM40-N0-15M-OG
Equipment protection level Gb
Type of protection intrinsic safety
CE marking 0102
Certificates
Appropriate type
ATEX certificate
ATEX marking
Standards
IECEx certificate
IECEx marking
Standards
Effective internal inductivity C
Effective internal inductance L
i
i
Maximum permissible ambient temperature T
Equipment protection level Gc (ic)
Type of protection intrinsic safety
CE marking
NCB10-30GM...-N0...
PTB 00 ATEX 2048 X
¬ II 1G Ex ia IIC T6…T1 Ga
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx PTB 11.0037X
Ex ia IIC T6 Ga
IEC 60079-0:2004 , IEC 60079-11:2006
≤ 105 nF
A cable length of 10 m is considered.
≤ 100 µH
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
at U
= 16 V , Ii = 25 mA , Pi = 34 mW ,
i
T6 : 76 °C (168.8 °F)
T5 : 91 °C (195.8 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
= 16 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 73 °C (163.4 °F)
T5 : 88 °C (190.4 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
= 16 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 62 °C (143.6 °F)
T5 : 77 °C (170.6 °F)
T4 : 81 °C (177.8 °F)
T3 : 81 °C (177.8 °F)
T2 : 81 °C (177.8 °F)
T1 : 81 °C (177.8 °F)
at U
= 16 V , Ii = 76 mA , Pi = 242 mW ,
i
T6 : 54 °C (129.2 °F)
T5 : 63 °C (145.4 °F)
T4 : 63 °C (145.4 °F)
T3 : 63 °C (145.4 °F)
T2 : 63 °C (145.4 °F)
T1 : 63 °C (145.4 °F)
Certificates
ATEX certificate
ATEX marking
Standards
Effective internal inductivity C
Effective internal inductance L
Maximum permissible ambient temperature T
i
i
amb
PF 13 CERT 2895 X
¬ II 3G Ex ic IIC T6...T1 Gc
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
≤ 105 nF
A cable length of 10 m is considered.
≤ 100 µH
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at U
= 20 V , Ii = 25 mA , Pi = 34 mW ,
i
T6 : 55 °C (131 °F)
T5 : 55 °C (131 °F)
T4 : 55 °C (131 °F)
T3 : 55 °C (131 °F)
T2 : 55 °C (131 °F)
T1 : 55 °C (131 °F)
at U
= 20 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 55 °C (131 °F)
T5 : 55 °C (131 °F)
T4 : 55 °C (131 °F)
T3 : 55 °C (131 °F)
T2 : 55 °C (131 °F)
T1 : 55 °C (131 °F)
at U
= 20 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 52 °C (125.6 °F)
T5 : 52 °C (125.6 °F)
T4 : 52 °C (125.6 °F)
T3 : 52 °C (125.6 °F)
T2 : 52 °C (125.6 °F)
T1 : 52 °C (125.6 °F)
at U
= 20 V , Ii = 76 mA , Pi = 242 mW ,
i
T6 : 44 °C (111.2 °F)
T5 : 44 °C (111.2 °F)
T4 : 44 °C (111.2 °F)
T3 : 44 °C (111.2 °F)
T2 : 44 °C (111.2 °F)
T1 : 44 °C (111.2 °F)
Release date: 2017-10-11 16:16 Date of issue: 2017-10-11 232395_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4
Inductive sensorNCB10-30GM40-N0-15M-OG
Equipment protection level Da
Type of protection intrinsic safety
CE marking 0102
Certificates
Appropriate type
ATEX certificate
ATEX marking
Standards
Effective internal inductivity C
Effective internal inductance L
i
i
Maximum permissible ambient temperature T
Equipment protection level Mb
Type of protection intrinsic safety
Certificates
Appropriate type
IECEx certificate
IECEx marking
Standards
Effective internal inductivity C
Effective internal inductance L
i
i
Maximum permissible ambient temperature T
NCB10-30GM...-N0...
PTB 00 ATEX 2048 X
¬ II 1D Ex ia IIIC T135°C Da
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
≤ 105 nF
A cable length of 10 m is considered.
≤ 100 µH
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
at U
= 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F)
i
at U
= 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F)
i
at U
= 16 V , Ii = 52 mA , Pi = 169 mW : 81 °C (177.8 °F)
i
at U
= 16 V , Ii = 76 mA , Pi = 242 mW : 63 °C (145.4 °F)
i
NCB10-30GM...-N0...
IECEx PTB 11.0037X
Ex ia I
IEC 60079-0:2004 , IEC 60079-11:2006
≤ 105 nF
A cable length of 10 m is considered.
≤ 100 µH
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
at U
= 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F)
i
at U
= 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F)
i
at U
= 16 V , Ii = 52 mA , Pi = 169 mW : 81 °C (177.8 °F)
i
at U
= 16 V , Ii = 76 mA , Pi = 242 mW : 63 °C (145.4 °F)