Inductive sensor NCB10-30GM40-N0-15M-OG
Technical Data
General specifications
Switching function Normally closed (NC) Output type NAMUR Rated operating distance sn10 mm Installation flush Assured operating distance sa0 ... 8.1 mm
0102
Model Number
NCB10-30GM40-N0-15M-OG
Features
• Shielded PUR cable for oil and gas sector
Accessories
BF 30
Mounting flange, 30 mm
Actual operating distance s Reduction factor rAl 0.32 Reduction factor r Reduction factor r Output type 3-wire
Nominal ratings
Nominal voltage Uo8 V Switching frequency f 0 ... 650 Hz Hysteresis H 1 ... 10 typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Suitable for 2:1 technology yes , Reverse polarity protection diode not required Current consumption
Measuring plate not detected Measuring plate detected
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 1870 a Mission Time (T Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 80 °C (-13 ... 176 °F) Storage temperature -40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Connection type cable PUR (halogen-free) , 15 m , screened , Oil resistant , Flame-
Core cross-section 2x 0.5 mm Housing material Stainless steel 1.4305 / AISI 303 Sensing face PBT Degree of protection IP66 / IP67 Cable
Bending radius
Note The shield is not connected to the sensor.
General information
Use in the hazardous area see instruction manuals
Compliance with standards and directives
Standard conformity
NAMUR
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
0.32
Cu
0.72
304
) 20 a
M
Dimensions
9 ... 11 mm typ.
r
3 mA 1 mA
retardant as per IEC 60332-1
> 7.5 x cable diameter
EN 60947-5-6:2000 IEC 60947-5-6:1999 EN 60947-5-2:2007 IEC 60947-5-2:2007
2
Release date: 2017-10-11 16:16 Date of issue: 2017-10-11 232395_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
M30x1,5
LED
37
40
5
36
1
Inductive sensor NCB10-30GM40-N0-15M-OG
Electrical Connection
1
2
L+
L-
Release date: 2017-10-11 16:16 Date of issue: 2017-10-11 232395_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Inductive sensor NCB10-30GM40-N0-15M-OG
Data for application in connection with hazardous areas
Equipment protection level Ga , Gb , Gc (ic) , Da , Mb
Equipment protection level Ga
Type of protection intrinsic safety
CE marking 0102
Certificates
Appropriate type
ATEX certificate
ATEX marking
Standards
IECEx certificate
IECEx marking
Standards
Effective internal inductivity C
Effective internal inductance L
i
i
Maximum permissible ambient temperature T
for ATEX
for IECEx
NCB10-30GM...-N0...
PTB 00 ATEX 2048 X ¬ II 1G Ex ia IIC T6...T1 Ga
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx PTB 11.0037X
Ex ia IIC T6 Ga
IEC 60079-0:2004 , IEC 60079-11:2006 , IEC 60079-26:2008
105 nF A cable length of 10 m is considered.
100 µH A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
= 16 V , Ii = 25 mA , Pi = 34 mW ,
at U
i
T6 : 59 °C (138.2 °F) T5 : 71 °C (159.8 °F) T4 : 99 °C (210.2 °F) T3 : 99 °C (210.2 °F) T2 : 99 °C (210.2 °F) T1 : 99 °C (210.2 °F) at U
= 16 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 56 °C (132.8 °F) T5 : 68 °C (154.4 °F) T4 : 96 °C (204.8 °F) T3 : 96 °C (204.8 °F) T2 : 96 °C (204.8 °F) T1 : 96 °C (204.8 °F) at U
= 16 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 45 °C (113 °F) T5 : 57 °C (134.6 °F) T4 : 81 °C (177.8 °F) T3 : 81 °C (177.8 °F) T2 : 81 °C (177.8 °F) T1 : 81 °C (177.8 °F) at U
= 16 V , Ii = 76 mA , Pi = 242 mW ,
i
T6 : 37 °C (98.6 °F) T5 : 49 °C (120.2 °F) T4 : 63 °C (145.4 °F) T3 : 63 °C (145.4 °F) T2 : 63 °C (145.4 °F) T1 : 63 °C (145.4 °F)
at Ui = 16 V , Ii = 25 mA , Pi = 34 mW , T6 : 59 °C (138.2 °F) T5 : 71 °C (159.8 °F) T4 : 99 °C (210.2 °F) T3 : 99 °C (210.2 °F) T2 : 99 °C (210.2 °F) T1 : 99 °C (210.2 °F) at U
= 16 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 56 °C (132.8 °F) T5 : 68 °C (154.4 °F) T4 : 96 °C (204.8 °F) T3 : 96 °C (204.8 °F) T2 : 96 °C (204.8 °F) T1 : 96 °C (204.8 °F) at U
= 16 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 45 °C (113 °F) T5 : 57 °C (134.6 °F) T4 : 81 °C (177.8 °F) T3 : 81 °C (177.8 °F) T2 : 81 °C (177.8 °F) T1 : 81 °C (177.8 °F) at U
= 16 V , Ii = 76 mA , Pi = 242 mW ,
i
T6 : 37 °C (98.6 °F) T5 : 49 °C (120.2 °F) T4 : 63 °C (145.4 °F) T3 : 63 °C (145.4 °F) T2 : 63 °C (145.4 °F) T1 : 63 °C (145.4 °F)
Release date: 2017-10-11 16:16 Date of issue: 2017-10-11 232395_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3
Inductive sensor NCB10-30GM40-N0-15M-OG
Equipment protection level Gb
Type of protection intrinsic safety
CE marking 0102
Certificates
Appropriate type
ATEX certificate
ATEX marking
Standards
IECEx certificate
IECEx marking
Standards
Effective internal inductivity C
Effective internal inductance L
i
i
Maximum permissible ambient temperature T
Equipment protection level Gc (ic)
Type of protection intrinsic safety
CE marking
NCB10-30GM...-N0...
PTB 00 ATEX 2048 X ¬ II 1G Ex ia IIC T6…T1 Ga
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx PTB 11.0037X
Ex ia IIC T6 Ga
IEC 60079-0:2004 , IEC 60079-11:2006
105 nF A cable length of 10 m is considered.
100 µH A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values. at U
= 16 V , Ii = 25 mA , Pi = 34 mW ,
i
T6 : 76 °C (168.8 °F) T5 : 91 °C (195.8 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U
= 16 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 73 °C (163.4 °F) T5 : 88 °C (190.4 °F) T4 : 100 °C (212 °F) T3 : 100 °C (212 °F) T2 : 100 °C (212 °F) T1 : 100 °C (212 °F) at U
= 16 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 62 °C (143.6 °F) T5 : 77 °C (170.6 °F) T4 : 81 °C (177.8 °F) T3 : 81 °C (177.8 °F) T2 : 81 °C (177.8 °F) T1 : 81 °C (177.8 °F) at U
= 16 V , Ii = 76 mA , Pi = 242 mW ,
i
T6 : 54 °C (129.2 °F) T5 : 63 °C (145.4 °F) T4 : 63 °C (145.4 °F) T3 : 63 °C (145.4 °F) T2 : 63 °C (145.4 °F) T1 : 63 °C (145.4 °F)
Certificates
ATEX certificate
ATEX marking
Standards
Effective internal inductivity C
Effective internal inductance L
Maximum permissible ambient temperature T
i
i
amb
PF 13 CERT 2895 X ¬ II 3G Ex ic IIC T6...T1 Gc
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
105 nF A cable length of 10 m is considered.
100 µH A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. at U
= 20 V , Ii = 25 mA , Pi = 34 mW ,
i
T6 : 55 °C (131 °F) T5 : 55 °C (131 °F) T4 : 55 °C (131 °F) T3 : 55 °C (131 °F) T2 : 55 °C (131 °F) T1 : 55 °C (131 °F) at U
= 20 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 55 °C (131 °F) T5 : 55 °C (131 °F) T4 : 55 °C (131 °F) T3 : 55 °C (131 °F) T2 : 55 °C (131 °F) T1 : 55 °C (131 °F) at U
= 20 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 52 °C (125.6 °F) T5 : 52 °C (125.6 °F) T4 : 52 °C (125.6 °F) T3 : 52 °C (125.6 °F) T2 : 52 °C (125.6 °F) T1 : 52 °C (125.6 °F) at U
= 20 V , Ii = 76 mA , Pi = 242 mW ,
i
T6 : 44 °C (111.2 °F) T5 : 44 °C (111.2 °F) T4 : 44 °C (111.2 °F) T3 : 44 °C (111.2 °F) T2 : 44 °C (111.2 °F) T1 : 44 °C (111.2 °F)
Release date: 2017-10-11 16:16 Date of issue: 2017-10-11 232395_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4
Inductive sensor NCB10-30GM40-N0-15M-OG
Equipment protection level Da
Type of protection intrinsic safety
CE marking 0102
Certificates
Appropriate type
ATEX certificate
ATEX marking
Standards
Effective internal inductivity C
Effective internal inductance L
i
i
Maximum permissible ambient temperature T
Equipment protection level Mb
Type of protection intrinsic safety
Certificates
Appropriate type
IECEx certificate
IECEx marking
Standards
Effective internal inductivity C
Effective internal inductance L
i
i
Maximum permissible ambient temperature T
NCB10-30GM...-N0...
PTB 00 ATEX 2048 X ¬ II 1D Ex ia IIIC T135°C Da
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
105 nF A cable length of 10 m is considered.
100 µH A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values. at U
= 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F)
i
at U
= 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F)
i
at U
= 16 V , Ii = 52 mA , Pi = 169 mW : 81 °C (177.8 °F)
i
at U
= 16 V , Ii = 76 mA , Pi = 242 mW : 63 °C (145.4 °F)
i
NCB10-30GM...-N0...
IECEx PTB 11.0037X
Ex ia I
IEC 60079-0:2004 , IEC 60079-11:2006
105 nF A cable length of 10 m is considered.
100 µH A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values. at U
= 16 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F)
i
at U
= 16 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F)
i
at U
= 16 V , Ii = 52 mA , Pi = 169 mW : 81 °C (177.8 °F)
i
at U
= 16 V , Ii = 76 mA , Pi = 242 mW : 63 °C (145.4 °F)
i
Release date: 2017-10-11 16:16 Date of issue: 2017-10-11 232395_eng.xml