Pepperl Fuchs NBN4-12GM40-E2 Data Sheet

Inductive sensor NBN4-12GM40-E2
Dimensions
M12x1
Model Number
NBN4-12GM40-E2
Features
Connection
BN
BK
BU
Accessories
BF 12
Mounting flange, 12 mm
LED
5
40
37
4
17
Technical Data
General specifications
Switching element function PNP NO Rated operating distance s
L+
L-
Installation non-flush Output polarity DC Assured operating distance sa0 ... 3.24 mm Reduction factor r Reduction factor rCu 0.4 Reduction factor r
Nominal ratings
Operating voltage UB10 ... 30 V Switching frequency f 0 ... 800 Hz Hysteresis H typ. 5% Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop Ud≤ 3 V Operating current I Off-state current I No-load supply current I Indication of the switching state all direction LED, yellow
Functional safety related parameters
MTTFd 3220 a Mission Time (T Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type cable PVC , 2 m Core cross-section 0.14 mm Housing material brass, nickel-plated Sensing face PBT Protection degree IP67
Compliance with standards and directives
Standard conformity
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval Products with a maximum operating voltage of 36 V do not bear a
0.45
Al
0.75
304
) 20 a
M
4 mm
n
0 ... 100 mA
L
0 ... 0.5 mA typ. 0.1 µA at 25 °C
r
15 mA
0
2
EN 60947-5-2:2007 IEC 60947-5-2:2007
CCC marking because they do not require approval.
Release date: 2012-11-15 11:59 Date of issue: 2012-11-15 083311_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs