Inductive sensor NBN30-U4K-N0
Technical Data
General specifications
Switching function Normally closed (NC)
Output type NAMUR
Rated operating distance sn30 mm
Installation non-flush
Assured operating distance sa0 ... 24.3 mm
Model Number
NBN30-U4K-N0
Features
• Sensor head bidirectional and
rotatable
• 30 mm non-flush
Accessories
MHW 01
Modular mounting bracket
Actual operating distance s
Reduction factor rAl 0.31
Reduction factor r
Reduction factor r
Output type 2-wire
Nominal ratings
Nominal voltage Uo8 V
Switching frequency f 0 ... 150 Hz
Hysteresis H typ. 5 %
Reverse polarity protection yes
Short-circuit protection yes
Current consumption
Measuring plate not detected
Measuring plate detected
Switching state indicator LED, yellow
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Storage temperature -40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection type screw terminals
Information for connection A maximum of two conductors with the same core cross section
Core cross-section up to 2.5 mm
Minimum core cross-section
Maximum core cross-section
Housing material PA/metal
Sensing face PA
Degree of protection IP68 / IP69K
Mass 225 g
Note Tightening torque: 1.8 Nm (housing)
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and
directives
Standard conformity
NAMUR
Electromagnetic compatibility
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
0.3
Cu
0.74
304
Dimensions
27 ... 33 mm typ. 30 mm
r
≥ 2.2 mA
≤ 1 mA
may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 %
without wire end ferrule 0.5 mm
without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm
1G; 2G; 3G
EN 60947-5-6:2000
IEC 60947-5-6:1999
NE 21:2007
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
2
2
, with connector sleeves 0.34 mm
2
2
Release date: 2017-11-15 13:01 Date of issue: 2017-11-15 213834_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
LED ye
LED ye
118
½ NPT”
40
6046
5.3
30
40
1

Inductive sensor NBN30-U4K-N0
Electrical Connection
1
2
Equipment protection level Ga
CE marking 0102
Effective internal inductivity C
Effective internal inductance L
Ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
Equipment protection level Gb
CE marking 0102
Effective internal inductivity C
Effective internal inductance L
Maximum permissible ambient temperature T
Equipment protection level Gc (ic)
CE marking
Effective internal inductivity C
Effective internal inductance L
Special conditions
for Pi=34 mW, Ii=25 mA, T6
for Pi=34 mW, Ii=25 mA, T5
for Pi=34 mW, Ii=25 mA, T4-T1
for Pi=64 mW, Ii=25 mA, T6
for Pi=64 mW, Ii=25 mA, T5
for Pi=64 mW, Ii=25 mA, T4-T1
for Pi=169 mW, Ii=52 mA, T6
for Pi=169 mW, Ii=52 mA, T5
for Pi=169 mW, Ii=52 mA, T4-T1
for Pi=242 mW, Ii=76 mA, T6
for Pi=242 mW, Ii=76 mA, T5
for Pi=242 mW, Ii=76 mA, T4-T1
Equipment protection level Da
Effective internal inductivity C
Effective internal inductance L
i
i
i
i
i
i
i
i
L+
L-
≤ 105 nF ; a cable length of 10 m is considered.
≤ 300 µH ; a cable length of 10 m is considered.
temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already
Note:
been applied to the temperature table for category 1.
≤ 105 nF ; a cable length of 10 m is considered.
≤ 300 µH ; a cable length of 10 m is considered.
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
amb
temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
≤ 105 nF ; a cable length of 10 m is considered.
≤ 300 µH ; A cable length of 10 m is considered.
73 °C (163.4 °F)
88 °C (190.4 °F)
100 °C (212 °F)
66 °C (150.8 °F)
81 °C (177.8 °F)
100 °C (212 °F)
45 °C (113 °F)
60 °C (140 °F)
89 °C (192.2 °F)
30 °C (86 °F)
45 °C (113 °F)
74 °C (165.2 °F)
≤ 105 nF ; a cable length of 10 m is considered.
≤ 300 µH ; a cable length of 10 m is considered.
Release date: 2017-11-15 13:01 Date of issue: 2017-11-15 213834_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2