Inductive sensor NBN12-18GM50-E0-M
Technical Data
General specifications
Switching function Normally open (NO)
Output type NPN
Rated operating distance sn12 mm
Installation non-flush
Output polarity DC
E
1
Model Number
NBN12-18GM50-E0-M
Features
•Basic series
• 12 mm non-flush
• E1-Type approval
• Extended temperature range
-40 ... +85 °C
• Increased noise immunity 100 V/m
Accessories
BF 18
Mounting flange, 18 mm
Assured operating distance s
Reduction factor rAl 0.45
Reduction factor r
Reduction factor r
Output type 3-wire
Nominal ratings
Operating voltage UB10 ... 60 V
Switching frequency f 0 ... 200 Hz
Hysteresis H type 5 %
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Vol tag e d rop Ud≤ 2.5 V
Operating current I
Off-state current I
No-load supply current I
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 1900 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type cable POC , 2 m
Core cross-section 3 x 0.75 mm
Housing material brass, nickel-plated
Sensing face PBT
Degree of protection IP68 / IP69K
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
E1 Type approval 10R-04
0.4
Cu
0.7
304
) 20 a
M
Dimensions
0 ... 9.72 mm
a
0 ... 200 mA
L
0 ... 0.5 mA typ. 0.1 µA at 25 °C
r
≤ 12 mA
0
2
EN 60947-5-2:2007
IEC 60947-5-2:2007
Electrical Connection
4
LED
BN
BK
BU
17
M18 x 1
L+
L-
10
47
50
Release date: 2017-05-03 09:44 Date of issue: 2017-05-03 219730_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Inductive sensor NBN12-18GM50-E0-M
Installation Hint
Emitted interference and interference immunity in
accordance with motor vehicle directive 2006/28/EG
(e1 Type approval)
Interference immunity in accordance with
DIN ISO 11452-2: 100 V/m
Frequency band 20 MHz up to 2 GHz
Mains-borne interference in accordance with ISO
7637-2: Pulse 1 2a 2b 3 a 3b 4 5
Severity level III III III III III III IV
Failure criterion C A C A A A C
EN 61000-4-2: CD: 8 kV / AD: 15 kV
Severity level IV IV
EN 61000-4-3: 30 V/m (80...2500 MHz)
Severity level IV
EN 61000-4-4: 2 kV
Severity level III
EN 61000-4-6: 10 V (0.01...80 MHz)
Severity level III
EN 55011: Class A
Release date: 2017-05-03 09:44 Date of issue: 2017-05-03 219730_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.