Pepperl Fuchs NBN12-18GK50-E0-M Data Sheet

Inductive sensor NBN12-18GK50-E0-M
Technical Data
General specifications
Switching function Normally open (NO) Output type NPN Rated operating distance sn12 mm Installation non-flush Output polarity DC
S
Model Number
NBN12-18GK50-E0-M
• 12 mm non-flush
• Extended temperature range
-40 ... +85 °C
• E1-Type approval
• Increased noise immunity 100 V/m
• With increased sealing, protection class IP68 / IP69K
• Highly shock and vibration resistant
Accessories
BF 18
Mounting flange, 18 mm
E 1
Assured operating distance s Reduction factor rAl 0.5 Reduction factor r Reduction factor r Reduction factor r Output type 3-wire
Nominal ratings
Operating voltage UB5 ... 60 V Switching frequency f 0 ... 1500 Hz Hysteresis H type 5 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Inductive overvoltage protection yes Surge suppression yes Vol tag e d rop U Rated insulation voltage U Operating current I Off-state current I No-load supply current I Time delay before availability t Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 846 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -40 ... 85 °C (-40 ... 185 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type cable PUR , 2 m Core cross-section 3 x 0.75 mm Housing material PBT Sensing face PBT Degree of protection IP68 / IP69K Mass 120 g
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
UL approval cULus Listed, General Purpose, Class 2 Power Source CSA approval cCSAus Listed, General Purpose, Class 2 Power Source CCC approval Certified by China Compulsory Certification (CCC) E1 Type approval 10R-04
0.45
Cu
0.7
304
0.5
Brass
0 ... 9.72 mm
a
2 V
d
60 V
BIS
0 ... 200 mA
L
0 ... 0.5 mA typ. 6 µA at 25 °C
r
7 mA
0
220 ms
v
2
EN 60947-5-2:2007 IEC 60947-5-2:2007
Dimensions
Electrical Connection
BN
BK
BU
M18 x 1
44
535
24
LED
L+
L-
Release date: 2017-05-03 09:43 Date of issue: 2017-05-03 248870_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive sensor NBN12-18GK50-E0-M
Installation Hint
Interference immunity in accordance with DIN ISO 11452-2: 100 V/m Frequency band 20 MHz up to 2 GHz
Mains-borne interference in accordance with ISO 7637-2: Pulse 1 2a 2b 3 a 3b 4 5 Severity level III III III III III III III Failure criterion C A C A A A B
EN 61000-4-2: CD: 8 kV / AD: 15 kV Severity level IV IV EN 61000-4-3: 30 V/m (80...2500 MHz) Severity level IV EN 61000-4-4: 2 kV Severity level III EN 61000-4-6: 10 V (0.01...80 MHz) Severity level III EN 55011: Class A
Release date: 2017-05-03 09:43 Date of issue: 2017-05-03 248870_eng.xml