Pepperl Fuchs NBB8-F33-E2-M Data Sheet

Inductive sensor NBB8-F33-E2-M
Technical Data
General specifications
Switching element function PNP NO
S
E
Model Number
Features
•8 mm flush
• E1-Type approval
• Extended temperature range ­40 ... +85 °C
• Increased operating distance
• Increased noise immunity 100 V/m
Rated operating distance s Installation flush Output polarity DC Assured operating distance sa0 ... 6.48 mm Reduction factor r Reduction factor rCu 0.2 Reduction factor r
Nominal ratings
Operating voltage UB5 ... 60 V DC Switching frequency f 0 ... 350 Hz Hysteresis H typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Vol tag e d rop Ud≤ 2 V Operating current I Off-state current I No-load supply current I
1
Time delay before availability t Switching state indicator LED yellow
Functional safety related parameters
MTTFd 1140 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -40 ... 85 °C (-40 ... 185 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type cable PUR , 2 m Core cross-section 0.5 mm Housing material PBT Sensing face PBT Degree of protection IP67 / IP69K Note Tightening torque: 5 Nm
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
CCC approval Certified by China Compulsory Certification (CCC) E1 Type approval 10R-04
0.3
Al
0.6
304
8 mm
n
0 ... 200 mA
L
0 ... 0.1 mA
r
10 mA
0
80 ms
v
EN 60947-5-2:2007 IEC 60947-5-2:2007
2
Dimensions
25
Electrical Connection
50
25
10
15
10
BN
BK
BU
LED
8
7.2
15
4.2
ø7.4
433
ø4.3
ø7.3
L+
L-
Release date: 2014-10-30 11:29 Date of issue: 2014-10-30 220777_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive sensor NBB8-F33-E2-M
Installation Hint
Emitted interference and interference immunity in accordance with motor vehicle directive 2006/28/EG (e1 Type approval) Interference immunity in accordance with DIN ISO 11452-2: 100 V/m Frequency band 20 MHz up to 2 GHz
Mains-borne interference in accordance with ISO 7637-2: Pulse 1 2a 2b 3 a 3b 4 5 Severity level III III III III III III IV Failure criterion C A C A A A C
EN 61000-4-2: CD: 8 kV / AD: 15 kV Severity level IV IV EN 61000-4-3: 30 V/m (80...2500 MHz) Severity level IV EN 61000-4-4: 2 kV Severity level III EN 61000-4-6: 10 V (0.01...80 MHz) Severity level III EN 55011: Class A
Release date: 2014-10-30 11:29 Date of issue: 2014-10-30 220777_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2