Pepperl Fuchs NBB8-18GM60-E2-M-340MM-3DT04-Y Data Sheet

Inductive sensor NBB8-18GM60-E2-M-340MM-3DT04-Y
Technical Data
General specifications
Switching function Normally open (NO) Output type PNP Rated operating distance sn8 mm Installation flush Output polarity DC
Model Number
NBB8-18GM60-E2-M-340MM-3DT04-Y
Mobile Equipment Series
Features
• Increased operating distance
• Extended temperature range
-40 ... +85 °C
• 3-pin Deutsch connector (DT04)
• 100 V/m radiated field immunity
Assured operating distance s Reduction factor rAl 0.45 Reduction factor r Reduction factor r Output type 3-wire
Nominal ratings
Operating voltage UB10 ... 60 V Switching frequency f 0 ... 400 Hz Hysteresis H typ. 5 % Reverse polarity protection yes Short-circuit protection yes Voltage drop Ud≤ 3 V Operating current I Off-state current I No-load supply current I Time delay before availability t Switching state indicator LED : yellow output
Functional safety related parameters
MTTFd 1630 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Cable connector Deutsch DT04 , 3-pin with PUR cable 340 mm Core cross-section 0.75 mm Housing material brass, nickel-plated Sensing face PBT Degree of protection IP68 / IP69K Note X = 340 mm
Compliance with standards and directives
Standard conformity
Standards
0.4
Cu
0.7
304
Dimensions
0 ... 6.48 mm
a
0 ... 200 mA
L
0 ... 0.5 mA typ. 0.1 µA at 25 °C
r
10 mA
0
20 ms
v
2
EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
64
59
M18 x 1
4
24
Electrical Connection
LED
(see note)
B
A
C
A
BK
B
X
L+
L-
BN (+)
C
BU (–)
Release date: 2017-10-18 11:22 Date of issue: 2017-10-18 307791_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive sensor NBB8-18GM60-E2-M-340MM-3DT04-Y
Installation Hint
Emitted interference and interference immunity in accordance with motor vehicle directive 2006/28/EG (e1 Type approval) Interference immunity in accordance with DIN ISO 11452-2: 100 V/m Frequency band 20 MHz up to 2 GHz
Mains-borne interference in accordance with ISO 7637-2: Pulse 1 2a 2b 3 a 3b 4 5 Severity level III III III III III III IV Failure criterion C A C A A A C
EN 61000-4-2: CD: 4 kV / AD: 8 kV Severity level II III EN 61000-4-3: 30 V/m (80...2500 MHz) Severity level IV EN 61000-4-4: 2 kV Severity level III EN 61000-4-6: 10 V (0.01...80 MHz) Severity level III EN 55011: Class A
Release date: 2017-10-18 11:22 Date of issue: 2017-10-18 307791_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2