Pepperl Fuchs NBB8-18GM50-E2-V1-3G-3D Data Sheet

Inductive sensor NBB8-18GM50-E2-V1-3G-3D
Technical Data
General specifications
Switching function Normally open (NO) Output type PNP Rated operating distance sn8 mm Installation flush Output polarity DC
Model Number
NBB8-18GM50-E2-V1-3G-3D
Features
• Increased operating distance
• ATEX-approval for zone 2 and zone 22
Accessories
BF 18
Mounting flange, 18 mm
EXG-18
Quick mounting bracket with dead stop
Assured operating distance s Reduction factor rAl 0.45 Reduction factor r Reduction factor r Output type 3-wire
Nominal ratings
Operating voltage UB10 ... 30 V DC Switching frequency f 0 ... 500 Hz Hysteresis H typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop Ud≤ 3 V Design data Operating current I Off-state current I No-load supply current I Time delay before availability t Switching state indicator Multihole-LED, yellow
Functional safety related parameters
MTTFd 2240 a Mission Time (T Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 4-pin Housing material brass, nickel-plated Sensing face PBT Degree of protection IP67
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and directives
Standard conformity
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
0.4
Cu
0.7
304
) 20 a
M
Dimensions
0 ... 6.48 mm
a
0 ... 200 mA
L
0 ... 0.5 mA typ. 0.1 µA at 25 °C
r
15 mA
0
20 ms
v
3G; 3D
EN 60947-5-2:2007 IEC 60947-5-2:2007
Electrical Connection
1
4
3
4
LED
24
M18 x 1
50
65
6
M12 x 1
L+
L-
Release date: 2016-11-07 10:02 Date of issue: 2018-02-19 129854_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive sensor NBB8-18GM50-E2-V1-3G-3D
Pinout
1
2
4
3
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK
(brown) (white) (blue) (black)
Equipment protection level Gc (nA)
Certificate PF 15CERT3754 X
CE marking
ATEX marking ¬ II 3G Ex nA IIC T6 Gc
Standards EN 60079-0:2012+A11:2013, EN 60079-15:2010
The Ex-related marking can also be printed on the enclosed label.
Ignition protection category "n" Use is restricted to the following stated conditions
Special conditions
Maximum operating current I
Maximum operating voltage U
L
Bmax
Maximum permissible ambient temperature T
at U
at U
at U
=30 V, IL=200 mA
Bmax
=30 V, IL=100 mA
Bmax
=30 V, IL=50 mA
Bmax
The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted.
The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible.
dependant of the load current I
Umax
Information can be taken from the following list.
and the max. operating voltage U
L
49 °C (120.2 °F)
54 °C (129.2 °F)
55 °C (131 °F)
Equipment protection level Dc
CE marking
Bmax
ATEX marking ¬ II 3D IP67 T 91 °C (195.8 °F) X
Standards EN 50281-1-1
The Ex-significant identification is on the enclosed adhesive label
Protection via housing Use is restricted to the following stated conditions
Special conditions
Maximum heating (Temperature rise)
at U
at U
at U
=30 V, IL=200 mA
Bmax
=30 V, IL=100 mA
Bmax
=30 V, IL=50 mA
Bmax
dependant of the load current IL and the max. operating voltage U Information can be taken from the following list. The maximum surface temperature at maximum ambient temperature is given in the Ex identification of the apparatus.
Bmax
21 K
16 K
14 K
Equipment protection level Dc (tc)
CE marking
ATEX marking ¬ II 3D Ex tc IIIC T80°C Dc
Standards EN 60079-0:2012+A11:2013, EN 60079-31:2014
General The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and
The Ex-related marking can also be printed on the enclosed label.
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet.
control draw see datasheets), form an integral part of this document. These documents can be found at The maximum surface temperature of the device was determined without a layer of dust of the information in this instruction manual is more specific than the information provided in the datasheet.
Special conditions
Maximum permissible ambient temperature T
at U
at U
at U
=30 V, IL=200 mA
Bmax
=30 V, IL=100 mA
Bmax
=30 V, IL=50 mA
Bmax
dependant of the load current I
Umax
Information can be taken from the following list.
49 °C (120.2 °F)
54 °C (129.2 °F)
55 °C (131 °F)
and the max. operating voltage U
L
Bmax
Equipment protection level Dc (tD)
2
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Release date: 2016-11-07 10:02 Date of issue: 2018-02-19 129854_eng.xml
Loading...
+ 1 hidden pages