Pepperl Fuchs NBB4-F1-UO Data Sheet

Inductive sensor NBB4-F1-UO
Dimensions
26
4
LED
12
Model Number
NBB4-F1-UO
•4 mm flush
• 2-wire AC/DC
Connection
BN
BU
AC/DC
4
3.2 x 5
S
4.5
4.5
3.2
4
6
M3
M3
40
4
Technical Data
General specifications
Switching element function AC/DC NC Rated operating distance s Installation flush Output polarity AC/DC Assured operating distance sa0 ... 3.24 mm Reduction factor r Reduction factor rCu 0.2 Reduction factor r
Nominal ratings
Operating voltage UB20 ... 253 V AC/DC Switching frequency f 0 ... 25 Hz Hysteresis H typ. 5% Reverse polarity protected reverse polarity protected Short-circuit protection pulsing Voltage drop Ud≤ 7 V Momentary current (20 ms, 0.1 Hz) Operating current I
Off-state current I No-load supply current I Operating voltage display LED, green Indication of the switching state LED, yellow
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type cable PVC , 2 m Core cross-section 0.5 mm Housing material PA Sensing face PA Protection degree IP67 Tightening torque, fastening screws Threading M3 max: 1.1 Nm
Compliance with standards and directives
Standard conformity
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval Certified by China Compulsory Certification (CCC)
0.3
Al
0.7
304
4 mm
n
0 ... 2100 mA
4 ... 250 mA AC
L
4 ... 100 mA DC 1. 7 m A
r
4 mA
0
EN 60947-5-2:2007 IEC 60947-5-2:2007
2
1016
Release date: 2012-06-04 10:29 Date of issue: 2012-06-04 188296_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
1