Inductive sensor NBB4-12GM50-E2-3G-3D
Technical Data
General specifications
Switching function Normally open (NO)
Output type PNP
Rated operating distance sn4 mm
Installation flush
Output polarity DC
Model Number
NBB4-12GM50-E2-3G-3D
Features
• Increased operating distance
•4 mm flush
• ATEX-approval for zone 2 and zone 22
Accessories
BF 12
Mounting flange, 12 mm
EXG-12
Quick mounting bracket with dead stop
Assured operating distance s
Reduction factor rAl 0.45
Reduction factor r
Reduction factor r
Nominal ratings
Operating voltage UB10 ... 30 V DC
Switching frequency f 0 ... 1000 Hz
Hysteresis H typ. 5 %
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Vol tag e d rop U
Operating current I
Off-state current I
Off-state current TU =40 °C, switching ele-
ment off
No-load supply current I
Time delay before availability t
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 1820 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type cable PVC , 2 m
Cable version PBT
Core cross-section 0.14 mm
Housing material brass, nickel-plated
Sensing face PBT
Degree of protection IP67
Cable
Bending radius
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
0.35
Cu
0.7
304
0 ... 3.24 mm
a
≤ 3 V
d
0 ... 150 mA
L
0 ... 0.5 mA typ. 0.1 µA at 25 °C
r
≤
≤ 15 mA
0
≤ 5 ms
v
2
> 10 x cable diameter
3G; 3D
EN 60947-5-2:2007
IEC 60947-5-2:2007
Dimensions
Electrical Connection
BN
BK
BU
17
M12 x 1
4
47
50
LED
L+
L-
Release date: 2016-11-07 10:11 Date of issue: 2016-11-07 212060_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Inductive sensor NBB4-12GM50-E2-3G-3D
Equipment protection level Gc (nA)
Instruction Manual electrical apparatus for hazardous areas
Device category 3G (nA) for use in hazardous areas with gas, vapour and mist
Certificate of Compliance PF 15CERT3754 X
CE marking
ATEX marking ¬ II 3G Ex nA IIC T6 Gc
Standards EN 60079-0:2012+A11:2013, EN 60079-15:2010
Ge n e r a l The apparatus has to be operated according to the appropriate data in the data sheet
Installation, commissioning Laws and/or regulations and standards governing the use or intended usage goal must
Maintenance No changes can be made to apparatus, which are operated in hazardous areas.
Special conditions
Maximum operating current I
Maximum operating voltage U
Maximum permissible ambient temperature T
at U
at U
Protection from mechanical danger
Protection from UV light
Protection of the connection cable
Protection against transients
Electrostatic charge
Material selection accessories
=30 V, IL=150 mA
Bmax
=30 V, IL=100 mA
Bmax
L
Bmax
Umax
The Ex-related marking can also be printed on the enclosed label.
Ignition protection category "n"
Use is restricted to the following stated conditions
and in this instruction manual.
The data stated in the data sheet are restricted by this operating instruction! The special
conditions must be obser ved!
be observed. If the Ex-related marking is printed only on the supplied label, then this
must be attached in the immediate vicinity of the sensor. The sticking surface for the
label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion.
Repairs to these apparatus are not possible.
The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted.
The maximum permissible operating voltage UB max is restricted to the values in the
following list. Tolerances are not permissible.
dependant of the load current I
Information can be taken from the following list.
45 °C (113 °F)
49 °C (120.2 °F)
The sensor must not be exposed to ANY FORM of mechanical danger.
The sensor and the connection cable must be protected from damaging UV-radiation.
This can be achieved when the sensor is used in internal areas.
The connection cable must be prevented from being subjected to tension and torsional
loading.
Ensure transient protection is provided and that the maximum value of the transient pro-
tection (140% of 85 V) is not exceeded.
Electrostatic charges must be avoided on the mechanical housing components. Dan-
gerous electrostatic charges on the mechanical housing components can be avoided by
incorporating these in the equipotential bonding.
When selecting accessories, ensure that the material allows the temperature of the
enclosure to rise to up to 70 °C.
and the max. operating voltage U
L
Bmax
Release date: 2016-11-07 10:11 Date of issue: 2016-11-07 212060_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2