Inductive sensor NBB4-12GM45-E2-M
Technical Data
General specifications
Switching element function PNP NO
S
Model Number
NBB4-12GM45-E2-M
•Basic series
•4 mm flush
• Increased operating distance
• Extended temperature range ­40 ... +85 °C
• E1-Type approval
• Increased noise immunity 100 V/m
Accessories
EXG-12
Quick mounting bracket with dead stop
Rated operating distance s Installation flush Output polarity DC Assured operating distance sa0 ... 3.24 mm Reduction factor r Reduction factor rCu 0.35 Reduction factor r
Nominal ratings
Operating voltage UB10 ... 60 V Switching frequency f 0 ... 800 Hz Hysteresis H typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Vol tag e d rop Ud≤ 2.5 V Rated insulation voltage U
E 1
Operating current I Off-state current I No-load supply current I Time delay before availability t Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 1530 a Mission Time (T Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type cable PUR , 2 m Core cross-section 0.75 mm Housing material brass, nickel-plated Sensing face PBT Degree of protection IP69K Mass 120 g
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
Protection class II
Rated insulation voltage U
Design-impulse-voltage withstan d U UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval Certified by China Compulsory Certification (CCC) E1 Type approval 10R-04
0.39
Al
0.75
304
) 20 a
M
4 mm
n
60 V
BIS
0 ... 200 mA
L
0 ... 0.5 mA typ. 0.1 µA
r
15 mA
0
5 ms
v
EN 60947-5-2:2007 IEC 60947-5-2:2007
60 V
i
800 V
imp
2
Dimensions
Electrical Connection
4
17
LED
BN
BK
BU
ø 12
M12 x 1
45
L+
L-
50
60
76
Release date: 2014-10-30 11:28 Date of issue: 2014-10-30 233861_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive sensor NBB4-12GM45-E2-M
Installation Hint
Emitted interference and interference immunity in accordance with motor vehicle directive 2006/28/EG (e1 Type approval) Interference immunity in accordance with DIN ISO 11452-2: 100 V/m Frequency band 20 MHz up to 2 GHz
Mains-borne interference in accordance with ISO 7637-2: Pulse 1 2a 2b 3 a 3b 4 Severity level III III III III III III Failure criterion C A C A A A
EN 61000-4-2: CD: 8 kV / AD: 15 kV Severity level IV IV EN 61000-4-3: 30 V/m (80...2500 MHz) Severity level IV EN 61000-4-4: 2 kV Severity level III EN 61000-4-6: 10 V (0.01...80 MHz) Severity level III EN 55011: Class A