Inductive sensor NBB3-V3-E2
Technical Data
General specifications
Switching function Normally open (NO)
Output type PNP
Rated operating distance sn3 mm
Installation flush
Output polarity DC
Model Number
NBB3-V3-E2
Features
•3 mm flush
•3-wire DC
Assured operating distance s
Reduction factor rAl 0.35
Reduction factor r
Reduction factor r
Reduction factor r
Output type 3-wire
Nominal ratings
Operating voltage UB10 ... 30 V DC
Switching frequency f 0 ... 1000 Hz
Reverse polarity protection reverse polarity protected
Short-circuit protection pulsing
Vol tag e d rop Ud≤ 3 V
Operating current I
Off-state current I
No-load supply current I
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 2300 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type cable PVC , 130 mm
Core cross-section 0.14 mm
Housing material PBT
Sensing face PBT
Degree of protection IP67
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
CCC approval CCC approval / marking not required for products rated ≤36 V
0.33
Cu
0.82
304
0.5
Brass
) 20 a
M
0 ... 2.43 mm
a
0 ... 100 mA
L
0 ... 0.5 mA typ. 0.1 µA at 25 °C
r
≤ 15 mA
0
2
EN 60947-5-2:2007
IEC 60947-5-2:2007
Dimensions
Electrical Connection
5.5
1010.3
ø 3
LED
16
22.2
27.8
BN
L+
BK
BU
L-
Release date: 2017-04-10 17:07 Date of issue: 2017-04-10 225235_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1