Inductive sensor NBB2-F76-E1-0,5M
Dimensions
28 ± 0.2
20
5.5 ± 0.1
ø 3.2
4
8 ± 0.1
Model Number
NBB2-F76-E1-0,5M
Features
•3-wire DC
Connection
BN
BK
BU
Technical Data
General specifications
Switching element function NPN normally closed Rated operating distance s Installation embeddable Output polarity DC Assured operating distance sa0 ... 1.62 mm Reduction factor r Reduction factor rCu 0.2 Reduction factor r Reduction factor r
Nominal ratings
Operating voltage UB10 ... 30 V DC Switching frequency f 0 ... 1500 Hz
L+
L-
Hysteresis H typ. 5 % Reverse polarity protected reverse polarity protected Short-circuit protection pulsing Voltage drop U Operating current I Off-state current I No-load supply current I Indication of the switching state LED yellow
Functional safety related parameters
MTTFd 828 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type cable PVC , 0.5 m Core cross-section 3 x 0.09 mm Housing material PC Protection degree IP67 Mass 5 g
Compliance with standards and directives
Standard conformity
Standards
Approvals and certificates
CCC approval Products with a maximum operating voltage of 36 V do not bear a
0.25
Al
0.63
304
0.31
Brass
2 mm
n
3 V
d
0 ... 100 mA
L
0 ... 0.5 mA typ. 10 µA at 25 °C
r
15 mA
0
2
EN 60947-5-2:2007 IEC 60947-5-2:2007
CCC marking because they do not require approval.
Release date: 2012-04-11 14:31 Date of issue: 2012-04-11 214956_eng.xml