Inductive sensor NBB25-FPS-A2
Technical Data
General specifications
Switching element function PNP NO/NC
Model Number
NBB25-FPS-A2
Features
• 25 mm flush
Rated operating distance s Installation flush Output polarity DC Assured operating distance sa0 ... 15.75 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Reduction factor rAl 0.5 Reduction factor r Reduction factor r Reduction factor r
Nominal ratings
Operating voltage UB10 ... 30 V DC Switching frequency f 0 ... 70 Hz Hysteresis H 0.05 ... 5.5 mm Reverse polarity protection yes Short-circuit protection yes Overload resistance yes Wire breakage protection yes Inductive overvoltage protection yes Surge suppression yes Ripple 10 % Vol tag e d rop U Repeat accuracy R 1 mm Operating current I Off-state current I No-load supply current I Time delay before availability t Operating voltage indicator LED, green Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 1390 a Mission Time (T Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 85 °C (-13 ... 185 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type screw terminals Core cross-section up to 2.5 mm Housing material PBT Sensing face PBT Housing base PBT Degree of protection IP65 Mass 270 g
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
CCC approval CCC approval / marking not required for products rated 36 V
0.4
Cu
0.8
304
0.5
Brass
) 20 a
M
25 mm
n
75 mm x 75 mm x 1 mm
2.5 V
d
0 ... 200 mA
L
0.01 mA
r
20 mA
0
100 ms
v
EN 60947-5-2:2007 IEC 60947-5-2:2007
2
Dimensions
LED
M20 x 1.5
24.545.2
77
ø9.6
ø 5.3
45
60
7
15.3
41
Release date: 2016-09-23 08:46 Date of issue: 2016-09-23 236511_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Inductive sensor NBB25-FPS-A2
Electrical Connection
Installation Hint
1
4
2
3
L+
L-
These sensors are especially designed for embeddable mounting in conveyor floors. Due to its precise location in metal base plates the sensor is afforded a high degree of mechanical protection. No clearance is required between the sensor and the base plate, avoiding the need for protective guarding to prevent possible foot injury.
The large sensing range ensures positive detection, and thus provides consistent control and monitoring of the conveyor.
Release date: 2016-09-23 08:46 Date of issue: 2016-09-23 236511_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2