Pepperl Fuchs NBB2-12GM50-E2 Data Sheet

Inductive sensor NBB2-12GM50-E2
Technical Data
General specifications
Switching element function PNP NO
Model Number
NBB2-12GM50-E2
Features
•2 mm flush
BF 12
Mounting flange, 12 mm
EXG-12
Quick mounting bracket with dead stop
Rated operating distance s Installation flush Output polarity DC Assured operating distance sa0 ... 1.62 mm Reduction factor r Reduction factor rCu 0.2 Reduction factor r
Nominal ratings
Operating voltage UB10 ... 30 V Switching frequency f 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Vol tag e d rop U Operating current I Off-state current I No-load supply current I Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 1060 a Mission Time (TM) 20 a Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type cable PVC , 2 m Core cross-section 0.14 mm Housing material brass, nickel-plated Sensing face PBT Degree of protection IP67
General information
Scope of delivery 2 self locking nuts in scope of delivery
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
EAC conformity TR CU 020/2011 UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
0.3
Al
0.7
304
2 mm
n
3 V
d
0 ... 200 mA
L
0 ... 0.5 mA typ. 0.1 µA at 25 °C
r
17 mA
0
2
EN 60947-5-2:2007 IEC 60947-5-2:2007
Dimensions
Electrical Connection
BN
BK
BU
M12x1
4
47
17
50
LED
L+
L-
Release date: 2016-06-16 14:11 Date of issue: 2016-06-16 087763_eng.xml