Pepperl Fuchs NBB20-U4-UU Specifications

6046
118
30
40
40
LED ye
LED ye
LED gn
5.3
½” NPT
Germany: +49 621 776 1111Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com

Inductive sensor

NBB20-U4-UU

Sensor head bidirectional and rotatable
<
NO/NC selectable
<
Comfort series
<
Metal base with ground connection
<

Technical Data

n
a
r
20 mm
0 ... 16.2 mm
18 ... 22 mm
General specifications
Switching function Normally open/closed (NO/NC)
Output type Two-wire
Rated operating distance s
Installation flush
Output polarity AC/DC
Assured operating distance s
Actual operating distance s
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Release date: 2020-12-10 Date of issue: 2020-12-10 Filename: 248043_eng.pdf
1
Inductive sensor NBB20-U4-UU
Germany: +49 621 776 1111Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com

Technical Data

Reduction factor r
0.77
304
Reduction factor rFe 1
Reduction factor r
0.43
Brass
Output type 2-wire
Nominal ratings
Switching frequency f AC, 0 ... 30 Hz
DC, 0 ... 100 Hz
Hysteresis H 1 ... 10 typ. 5 %
Reverse polarity protection reverse polarity tolerant
Short-circuit protection pulsing
Voltage drop U
Momentary current
≤ 5 V (typ. 2V) DC operation
d
≤ 8 V (typ. 2V) AC operation
0 ... 3000 mA
(20 ms, 0.1 Hz)
Operating current I
Off-state current I
Time delay before availability t
L
r
v
5 ... 500 mA
≤ 1.5 mA
≤ 300 ms
Operating voltage indicator LED, green
Switching state indicator LED, yellow
Error indicator flashes when overcurrent
Functional safety related parameters
MTTF
d
540 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Electrical specifications
Rated operating voltage U
Operating voltage U
24 ... 250 V DC / 24 ... 230 V AC
e
20 ... 300 V DC / 20 ... 253 V AC
B
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007
EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
Approvals and certificates
Protection class I
Rated insulation voltage U
Rated impulse withstand voltage U
i
imp
230 V
2.5 kV
UL approval cULus Listed, General Purpose
CCC approval Ue 75VDC - 250VDC Ue 75VAC - 230VAC
Ambient conditions
Ambient temperature -25 ... 85 °C (-13 ... 185 °F)
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Mechanical specifications
Connection type terminal compartment
Information for connection A maximum of two conductors with the same core cross section may be mounted on
one terminal connection! tightening torque 1.2 Nm + 10 %
Core cross-section up to 2.5 mm
Minimum core cross-section without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm
Maximum core cross-section without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm
2
2
2
Housing material PA 6.6 / metal
Sensing face PA 6.6
Housing base metal / class I equipment with ground connection
Degree of protection IP67
Release date: 2020-12-10 Date of issue: 2020-12-10 Filename: 248043_eng.pdf