Technical Data
General specifications
Switching element function AC NO
Rated operating distance s
Installation embeddable
Output polarity AC
Assured operating distance sa0 ... 12.15 mm
Reduction factor r
Reduction factor rCu 0.28
Reduction factor r
Nominal ratings
Operating voltage UB20 ... 250 V
Switching frequency f 0 ... 20 Hz
Hysteresis H typ. 5 %
Short-circuit protection no
Voltage drop U
Momentary current
(20 ms, 0.1 Hz)
Operating current I
No-load supply current I
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type terminal compartment
Core cross-section up to 2.5 mm
Housing material PBT
Sensing face PBT
Protection degree IP67
Note
Compliance with standards and directives
Standard conformity
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval Certified by China Compulsory Certification (CCC)
0.33
Al
0.82
304
15 mm
n
≤ 8 V
d
0 ... 1600 mA
1.5 ... 200 mA
L
≤ 1. 7 m A
0
2
1)
In the temperature range below 0 °C, permissible operating vol-
tage U
80...253 V
b
Safety fuse ≤ 0.3 A (quick-blow) according to IEC 60127-2 Sheet 1
Recommendation: after a short circuit, check that the device is
functioning correctly.
EN 60947-5-2:2007
IEC 60947-5-2:2007
M16x1,5
Release date: 2012-04-04 12:04 Date of issue: 2012-04-04 802849_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
1