Pepperl Fuchs NBB1-4GM22-E2 Data Sheet

Pepperl Fuchs NBB1-4GM22-E2 Data Sheet

Inductive sensor

Model Number

NBB1-4GM22-E2

Features

1 mm flush

Miniature design

Connection

BN L+

BK

BU L-

Accessories

BF 4

Mounting flange, 4 mm

<![if ! IE]>

<![endif]>Release date: 2012-05-22 11:15 Date of issue: 2012-05-22 206385_eng.xml

Subject to modifications without notice

NBB1-4GM22-E2

Dimensions

<![if ! IE]>

<![endif]>2

<![if ! IE]>

<![endif]>16.5 22

7 LED

M4 x 0.5

Technical Data

General specifications

 

 

 

Switching element function

 

PNP

NO

Rated operating distance

sn

1 mm

 

Installation

 

flush

 

Output polarity

 

DC

 

Assured operating distance

sa

0 ... 0.81 mm

Reduction factor rAl

 

0.4

 

Reduction factor rCu

 

0.29

 

Reduction factor r304

 

0.76

 

Reduction factor rBrass

 

0.46

 

Nominal ratings

 

 

 

 

 

 

 

Operating voltage

UB

10 ... 30 V

 

Switching frequency

f

0 ... 700 Hz

 

Hysteresis

H

typ. 5%

 

Reverse polarity protected

 

reverse polarity protected

Short-circuit protection

 

pulsing

 

Voltage drop

Ud

3 V

 

Operating current

IL

0 ... 100 mA

Off-state current

Ir

0 ... 0.1 mA typ. at 25 °C

No-load supply current

I0

10 mA

 

Indication of the switching state

 

LED, yellow

Functional safety related parameters

 

 

MTTFd

 

1340 a

 

Mission Time (TM)

 

20 a

 

Diagnostic Coverage (DC)

 

0 %

 

Ambient conditions

 

 

 

Ambient temperature

 

-25 ... 70 °C (-13 ... 158 °F)

Mechanical specifications

 

 

 

Connection type

 

cable PUR , 2 m

Core cross-section

 

0.055 mm2

 

Housing material

 

Stainless steel 1.4305 / AISI 303

Sensing face

 

PC

 

Protection degree

 

IP67

 

Compliance with standards and directives

 

 

 

 

 

 

Standard conformity

 

 

 

Standards

 

EN 60947-5-2:2007

 

 

IEC 60947-5-2:2007

 

 

 

 

Approvals and certificates

 

 

 

 

 

 

UL approval

 

cULus Listed, General Purpose

CSA approval

 

cCSAus Listed, General Purpose

 

 

 

CCC approval

 

Products with a maximum operating voltage of 36 V do not bear a

 

 

CCC marking because they do not require approval.

 

 

 

 

Copyright Pepperl+Fuchs

1