Pepperl Fuchs NBB10-30GM50-WO Data Sheet

Inductive sensor NBB10-30GM50-WO
Dimensions
M30 x 1.5
Model Number
NBB10-30GM50-WO
Features
• Basic series
• 10 mm embeddable
•2-wire AC
Connection
BN
BU
GN/YE
L
N
Accessories
BF 30
Mounting flange, 30 mm
EXG-30
Quick mounting bracket with dead stop
5
S
36
LED(s)
47
50
ø 28.2
Technical Data
General specifications
Nominal ratings
Operating voltage UB20 ... 253 V Switching frequency f 0 ... 20 Hz Hysteresis H typ. 5 % Reverse polarity protected tolerant Voltage drop U Momentary current (20 ms, 0.1 Hz) Operating current I Off-state current I Operating voltage display LED, green Indication of the switching state LED, yellow
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type cable PVC , 2 m Core cross-section 0.75 mm Housing material brass, nickel-plated Sensing face PBT Protection degree IP67 Note
Compliance with standards and directives
Standard conformity
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval Certified by China Compulsory Certification (CCC)
0.33
Al
0.81
303
10 mm
n
< 5 V (IL > 50 mA); < 8 V (IL < 50 mA)
d
0 ... 1600 mA
5 ... 200 mA
L
0 ... 1.7 mA
r
2
1)
In the temperature range below 0 °C, permissible operating vol-
tage U
80...253 V
b
Safety fuse 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.
EN 60947-5-2:2007 IEC 60947-5-2:2007
Release date: 2011-07-14 10:59 Date of issue: 2011-07-14 801647_eng.xml
Subject to modifications without notice
Copyright Pepperl+Fuchs
1
Loading...