Pepperl Fuchs NBB10-30GKK-WS Data Sheet

Inductive sensor NBB10-30GKK-WS
Dimensions
Model Number
NBB10-30GKK-WS
• Basic series
• 10 mm embeddable
Connection
BN
BU
L
N
M30x1,5
5
36
S
M16x1,5
40
2
58
115
M16x1,5
40
Technical Data
General specifications
Switching element function AC NO Rated operating distance s Installation embeddable Output polarity AC Assured operating distance sa0 ... 8.1 mm Reduction factor r Reduction factor rCu 0.28 Reduction factor r
Nominal ratings
Operating voltage UB20 ... 250 V Switching frequency f 0 ... 20 Hz Hysteresis H typ. 5 % Short-circuit protection no Voltage drop U Momentary current (20 ms, 0.1 Hz) Operating current I No-load supply current I
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type terminal compartment Core cross-section up to 2.5 mm Housing material PBT Sensing face PBT Protection degree IP67 Note
Compliance with standards and directives
Standard conformity
Standards
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval Certified by China Compulsory Certification (CCC)
0.33
Al
0.82
304
10 mm
n
8 V
d
0 ... 1600 mA
1.5 ... 200 mA
L
1. 7 mA
0
2
1)
In the temperature range below 0 °C, permissible operating vol-
tage U
80...253 V
b
Safety fuse 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.
EN 60947-5-2:2007 IEC 60947-5-2:2007
M16x1,5
Release date: 2012-04-04 12:04 Date of issue: 2012-04-04 802847_eng.xml
Subject to modifications without notice