Magnetic field sensor MC60-12GM50-1N-V1
Technical Data
General specifications
Switching function Normally open (NO)
Output type NAMUR
Rated operating distance sn60 mm
Installation flush in non-magnetic metal
Assured operating distance sa10 ... 48.6 mm
Output type 2-wire
Nominal ratings
Nominal voltage Uo8.2 V (Ri approx. 1 kΩ)
Switching frequency f 0 ... 5000 Hz
0102
Model Number
MC60-12GM50-1N-V1
Features
• 60 mm flush with permanent magnet
DM 60-31-15
Accessories
BF 12
Mounting flange, 12 mm
EXG-12
Quick mounting bracket with dead stop
DM 60-31-15
Permanent magnet for magnetic field sensors
DM 25-32-07
Permanent magnet for magnetic field sensors
V1-G
Female connector, M12, 4-pin, field attachable
V1-W
Female connector, M12, 4-pin, field attachable
V1-G-N-2M-PUR
Female cordset, M12, 2-pin, NAMUR, PUR cable
V1-W-N-2M-PUR
Female cordset, M12, 2-pin, NAMUR, PUR cable
Current consumption
Magnet detected
Magnet not detected
Switching state indicator LED, yellow
Functional safety related parameters
MTTFd 4382 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 4-pin
Housing material stainless steel 1.4404 / AISI 316L
Sensing face stainless steel 1.4404 / AISI 316L
Degree of protection IP67
General information
Use in the hazardous area see instruction manuals
Category
Compliance with standards and
directives
Standard conformity
NAMUR
Standards
Approvals and certificates
FM approval
Control drawing
CCC approval CCC approval / marking not required for products rated ≤36 V
) 20 a
M
Dimensions
≥ 2.5 mA
≤ 1 mA
2G
EN 60947-5-6:2000
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
116-0165
M12x1
4
40
17
63
Release date: 2018-02-26 10:28 Date of issue: 2018-02-26 183132_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
Electrical Connection
LED
M12x1
1
2, 3, 4
L+
L-
1

Magnetic field sensor MC60-12GM50-1N-V1
Pinout
1
2
4
3
Magnet
Magnet
DM 60-31-15
DM 25-32-07
Equipment protection level Gb
CE marking 0102
ATEX marking ¬ II 2G Ex ib IIC T6 Gb
Standards EN 60079-0:2012+A11:2013, EN 60079-11:2012
Appropriate type MC60-12GM50-1N-V1
Effective internal inductivity C
Effective internal inductance L
Special conditions
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
i
i
Ignition protection "Intrinsic safety"
Use is restricted to the following stated conditions
≤ 15 nF ; a cable length of 10 m is considered.
≤ 35 µH ; a cable length of 10 m is considered.
2
Release date: 2018-02-26 10:28 Date of issue: 2018-02-26 183132_eng.xml