Optical data coupler
Dimensions
90
97.5
36
LS610-DA-P/F1
Model Number
LS610-DA-P/F1
Optical data coupler
Features
•Devices for PROFIBUS
• Problem-free light beam interruption
due to TVT (Telegram Verification
Te c h n o l o g y )
• Plug connection for fast mounting
• Simple programming without opening
the device
• Usable up to detection range 0
• Line indicator for signal strength
R
Electrical connection
n.c.
1
Rx/Tx-N
2
n.c.
3
4
Rx/Tx-P
5
Shield Shield
Plug M12 x 1, 5-pin
B-coded
81
170
Bus IN
Connector M12 x 1, 5-pin
B-coded
Bus OUT/Termination
Socket M12 x 1, 5-pin
B-coded
Power
Connector M12 x 1, 4-pin
BUS OUT/TerminationBUS IN
VP
1
Rx/Tx-N
2
DGND
3
4
Rx/Tx-P
5
Socket M12 x 1, 5-pin
B-coded
Power
1
2
3
4
Plug M12 x 1, 4-pin
A-coded
171
+UB+UB
Keylock
0 V
Alarm
Release date: 2013-08-21 10:27 Date of issue: 2013-08-21 131632_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Optical data coupler
LS610-DA-P/F1
Technical data
General specifications
Effective detection range 0 ... 120 m
Threshold detection range 140 m
Light type modulated infrared light
Approvals CE, cULus
Diameter of the light spot 2 m at a distance of 100 m
Angle of divergence 1.1 °
Ambient light limit > 10000 Lux
Functional safety related parameters
MTTFd 250 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Data flow display LED green: emitter
Function display alignment aid: flashing front red LED Signal strength (8 LED:
Controls membrane keys, 2 keys, can be electrically locked
Electrical specifications
Operating voltage UB18 ... 30 V DC
No-load supply current I
Data rate 93.75; 187.5;(350); 500;1500 kBit/s , adjustable
Operation frequency F1 = 8.25 MHz
Interface
Interface type PROFIBUS, galvanically isolated
Input
Function input Keylock, internal Pull-up resistor
Output
Pre-fault indication output 1 PNP (switches if there is sufficient stability control) short-circuit
Sta nd ard confor mi ty
Standards EN 60947-5-2 , CE , EN 61000-6-2
Ambient conditions
Ambient temperature -10 ... 50 °C (14 ... 122 °F)
Storage temperature -20 ... 70 °C (-4 ... 158 °F)
Mechanical specifications
Protection degree IP65
Connection 4-pin, M12x1 connector, standard (supply) ,
Material
Housing ABS / PC
Optical face plastic
Mass 700 g
) 20 a
M
0
LED yellow: receiver LED red: faulty telegram
Red, yellow, green) Baudrate, operating mode
200 mA
keypad locked with 0 V
protected, max. 200 mA
5-pin, M12x1 connector, B-coded (Bus In) ,
5-pin, M12x1 socket, B-coded (Bus Out/Termination)
Curves/Diagrams
Accessories
ICZ-TR-V15B
Terminal resistor for PROFIBUS
V15SB-G
Cable connector, M12, for PROFIBUS,
adjustable
V15B-G
Cable socket, M12, for PROFIBUS, adjustable
V15-G-PG9
Female connector, M12, 5-pin, field attachable
Funktionserdung LS610/VDM100 Zubehoer
Function grounding for LS610 / LS611 /
VDM100 series
Schutzkappe LS610 Zubehoer
M12 protective cap set (connector + socket) for series LS610 / LS611
OMH-LS610-01
Mounting bracket for optical data coupler
OMH-LS610-02
Direct mounting set consisting of 4 x M4
threaded inserts
OMH-LS610-03
Mounting bracket with deviation mirror for
optical data coupler
OMH-LS610-05
Mounting bracket for optical data coupler
and distance measurement devices
OMH-LS610-31
Mounting bracket for optical data coupler
and distance measurement devices
OMH-LS610-32
Mounting bracket for optical data coupler
and distance measurement devices
Characteristic response curve
Offset Y [mm]
1400
1200
1000
800
600
400
200
0
0 20 40 60 80 100 120
x
y
Function
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
LS 610-DA...
Distance X [m]
Release date: 2013-08-21 10:27 Date of issue: 2013-08-21 131632_eng.xml