Pepperl Fuchs KFD2-UT2-2-1 Technical Data

Universal Temperature Converter

2

KFD2-UT2-2-1

2
3
1
+
-
T
T
+
-
T
5
6
4
24 V DC
14+ 15-
Power Rail
24 V DCERR
7-
8+
+
-
T
+
-
T
10-
11+
I
II
V
V
K-CJC-**
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
pa-info@de.pepperl-fuchs.com
KFD2-UT2-2-1
2-channel signal conditioner
<
24 V DC supply (Power Rail)
<
Thermocouple, RTD, potentiometer or voltage input
<
Usable as signal splitter (1 input and 2 outputs)
<
Voltage output 0/1 V ... 5 V
<
<
Line fault (LFD) and sensor burnout detection
<
Up to SIL 2 acc. to IEC 61508/IEC 61511
<
Voltage output 0/1 V ... 5 V

Function

This signal conditioner provides the galvanic isolation between field circuits and control circuits. The device converts the signal of a resistance thermometer, thermocouple, or potentiometer to a proportional output voltage. The device can also be configured as a signal splitter. The removable terminal block K-CJC-** is available as an accessory for internal cold junction compensation of thermocouples. A fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output. The device is easily configured by the use of the PACTware configuration software. For additional information, refer to the manual and www.pepperl-fuchs.com.

Connection

Technical Data

General specifications
Signal type Analog input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply
Connection terminals 14+, 15- or power feed module/Power Rail
Rated voltage U
Ripple within the supply tolerance
Power dissipation/power consumption ≤ 0.8 W / 0.8 W
Interface
Release date: 2020-09-23 Date of issue: 2020-09-23 Filename: 248763_eng.pdf
r
20 ... 30 V DC
1
Universal Temperature Converter KFD2-UT2-2-1
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
pa-info@de.pepperl-fuchs.com

Technical Data

Programming interface programming socket
Input
Connection side field side
Connection terminals 1, 2, 3; 4, 5, 6
RTD type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
Measuring current approx. 200 µA with RTD
Types of measuring 2-, 3-wire connection
Lead resistance max. 50 Ω per line
Measurement loop monitoring sensor breakage, sensor short-circuit
Thermocouples type B, E, J, K, N, R, S, T (IEC 584-1: 1995)
Cold junction compensation external and internal
Measurement loop monitoring sensor breakage
Potentiometer 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)
Voltage selectable within the range -100 ... 100 mV
Input resistance ≥ 1 MΩ (-100 ... 100 mV)
Output
Connection side control side
Voltage output 0 ... 5 V or 1 ... 5 V ; output resistance: ≤ 5 Ω ; load: ≥ 10 kΩ
Connection output I: terminals 7-, 8+
Fault signal downscale 0 V or 0.5 V, upscale 5.375 V
Transfer characteristics
Deviation
After calibration Pt100: ± (0.06 % of measurement value in K + 0.1 K (4-wire connection))
Influence of ambient temperature deviation of CJC included:
Influence of supply voltage < 0.01 % of span
Reaction time worst case value (sensor breakage and/or sensor short circuit detection enabled)
Galvanic isolation
Input/Other circuits basic insulation according to IEC 61010-1, rated insulation voltage 300 V
Output/supply, programming input functional insulation, rated insulation voltage 50 V AC
Indicators/settings
Display elements LEDs
Configuration via PACTware
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001
Release date: 2020-09-23 Date of issue: 2020-09-23 Filename: 248763_eng.pdf
type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760)
type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001)
output II: terminals 10-, 11+
thermocouple: ± (0.05 % of measurement value in °C + 1 K (1.2 K for types R and S)) this includes ± 0.8 K error of the cold junction compensation mV: ± 50 µV potentiometer: ± 0.05 % of full scale, (excludes errors due to lead resistance) output: 1 to 5 V output: ± 4 mV from 0 to 103.1 % of span; 0 to 5 V output: ± 4 mV from
0.3 to 102.5 % of span
Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔT thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K
*)
ΔT
amb
mV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔT potentiometer: ± 0.006 % of span/K ΔT
*)
ΔT
= ambient temperature change referenced to 23 °C (296 K)
amb
amb
*)
amb
*)
amb
*)
mV: 1.2 s, thermocouples with CJC: 1.4 s, thermocouples with fixed ref. temp: 1.4 s, 3­or 4-wire RTD: 1.1 s, 2-wire RTD: 920 ms, Potentiometer: 3-wire connection 2.8 s, 2-wire connection 2.25 s
eff
There is no electrical isolation between the programming input and the supply. The programming cable provides galvanic isolation so that ground loops are avoided.
2
Loading...
+ 2 hidden pages