HART Loop Converter
KFD2-HLC-Ex1.D.2W
7
8+
9-
14+
15-
13
20+
21-
19
Zone 2
Div. 2
I
II
10
11
12
16
17
18
24 V DC
23+
24-
22
Power Rail
24 V DCERR
HART
+
IV
V
III
Zone 0, 1, 2
Div. 1, 2
HART
+
-
HART
+
-
+
HART
-
mA
mA
mA
mA
V
+
-
V
+
-
V
1+
2+
3-
4
5
6
250 Ω
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
pa-info@de.pepperl-fuchs.com
KFD2-HLC-Ex1.D.2W
1-channel isolated barrier
<
24 V DC supply (Power Rail)
<
HART field device input with transmitter power supply
<
Usable as signal splitter (1 input and several outputs)
<
2 relay contact outputs (change-over contacts)
<
3 analog outputs 4 mA ... 20 mA
<
Sink and source mode output
<
Configurable by keypad
<
Function
This isolated barrier is used for intrinsic safety applications. It is a HART loop converter that provides power to transmitters or can be connected to
existing HART loops in parallel.
It is able to evaluate up to four HART variables (PV, SV, TV, QV). Of those four HART variables, the data contained in any three of them can be
converted to three different 4 mA ... 20 mA current signals. These loop signals can be connected to display devices or analog inputs on the
process control system/ control system.
In addition to the current outputs, two form C changeover relay contacts are available and can be programmed to operate at trip values from the
HART variables.
The unit is easily programmed by the use of a keypad located on the front of the unit or with the PACTware™ configuration software.
For additional information, refer to the manual and www.pepperl-fuchs.com.
Connection
Technical Data
General specifications
Signal type Analog input
Supply
Connection Power Rail or terminals 23+, 24-
Rated voltage U
Rated current I
Power dissipation 2.5 W
Power consumption 3.1 W
HART signal channels (intrinsically safe)
Release date: 2020-09-23 Date of issue: 2020-09-23 Filename: 261918_eng.pdf
19 ... 30 V DC
r
approx. 130 mA at 24 V DC
r
1

HART Loop Converter KFD2-HLC-Ex1.D.2W
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
pa-info@de.pepperl-fuchs.com
Technical Data
Conformity HART field device input (revision 5 to 7)
Interface
Programming interface programming socket
Input
Connection side field side
Connection terminals 1, 2, 3, 4, 5, 6
Open circuit voltage/short-circuit current typ. 24 V / 28 mA
Input resistance 250 Ω , 5 % (terminals 2, 3 and with jumper on 5, 6)
Available voltage ≥ 15.5 V at 20 mA, short-circuit protected
Output
Connection side control side
Connection output I: terminals 10, 11, 12, output II: terminals 16, 17, 18
Output I, II
Output signal relay and LED yellow
Mechanical life 107 switching cycles
Energized/De-energized delay approx. 20 ms / approx. 20 ms
Output III, IV, V
Output signal analog
Current range 4 ... 20 mA , (source or sink mode)
Load max. 650 Ω , source mode
Voltage range 5 ... 30 V , sink mode from external supply
Fault signal downscale I ≤ 2 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) or hold measurement
Other outputs HART communicator on terminals 22, 24
Collective error message Power Rail and LED red
Transfer characteristics
Output III, IV, V
Resolution max. 2 µA
Accuracy < 20 µA, 10 µA typ.
Influence of ambient temperature < ± 2 µA/K
Duration of measurement/Response delay HART message acquisition time plus 100 ms
Relay programmable either for fault or trip value (with direction, hysteresis and delay)
Galvanic isolation
Output I/II functional insulation acc. to IEC 62103, rated insulation voltage 250 V
Output I, II/other circuits reinforced insulation acc. to IEC 62103, rated insulation voltage 300 V
Output III/IV/V/power supply functional insulation acc. to IEC 62103, rated insulation voltage 50 V
Indicators/settings
Display elements LEDs , display
Control elements Control panel
Configuration via operating buttons
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EU EN 61010-1:2010
Conformity
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Release date: 2020-09-23 Date of issue: 2020-09-23 Filename: 261918_eng.pdf
output III: terminals 7, 8, 9, output IV: terminals 13, 14, 15, output V: terminals 19, 20,