1-channel signal conditioner
<
24 V DC supply (loop powered)
<
2- or 3-wire Pt100 RTD input
<
Output 4 mA ... 20 mA, temperature linearization selectable
<
DIP switch selectable ranges
<
<

Function

This isolated signal conditioner is a loop-powered isolator that converts the resistance from a 3-wire RTD to a 4 mA ... 20mA signal and provides isolation for non-intrinsically safe applications. A selectable analog linearization ensures a temperature linear 4 mA ... 20mA output between 25 °C ... 375 °C. It also features conveniently located DIP switches and potentiometers to make field calibration easy.

Connection

Technical Data

General specifications
Signal type Analog input
Supply
Rated voltage U
Power dissipation 0.4 W
Input
Connection side field side
Connection terminals 1, 2-, 3+
Lead resistance max. 100 Ω per line
Measuring current approx. 1 mA
Output
Release date: 2020-09-23 Date of issue: 2020-09-23 Filename: 038307_eng.pdf
12 ... 35 V DC loop powered
r
suitable for Pt100, 2- and 3-wire connection
1
RTD Converter KFD0-TR-1
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
pa-info@de.pepperl-fuchs.com

Technical Data

Connection side control side
Connection terminals 9+, 8-
Load (U -12 V) / 0.02 A
Current output 4 ... 20 mA , limited to ≤ 35 mA
Fault signal sensor burnout: upscaling ≥ 22 mA , limited to ≤ 35 mA
Transfer characteristics
Measurement range f
Deviation
After calibration 0.1 % of full-scale value
Influence of ambient temperature span and zero point 0.015 % / K or ± 10 mΩ / K
Influence of supply voltage 6.5 ppm/V
Rise time 250 ms
Galvanic isolation
Input/Output safe isolation acc. to DIN VDE 0106, rated insulation voltage 253 V
Indicators/settings
Control elements DIP-switch
Configuration via DIP switches
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Conformity
Insulation coordination EN 50178
Galvanic isolation EN 50178
Degree of protection IEC 60529
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass approx. 150 g
Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B2
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals
span without linearization 25 ... 800 °C (77 ... 1472 °F)/ with linearisation 25 ... 375 °C
n
(77 ... 707 °F) zero point without linearization -200 ... 400 °C (-328 ... 752 °F)/ with linearisation -30 ... 375 °C (-22 ... 707 °F) span and zero point adjustable
eff
rotary switch
via rotary switch
where applicable. For information see www.pepperl-fuchs.com.
Release date: 2020-09-23 Date of issue: 2020-09-23 Filename: 038307_eng.pdf