Timer, Counter KCY1-6SR-B
Technical data
General specifications
Model Number
KCY1-6SR-B
Pulse/batch controller
Features
• Simple pre-selection setting via one
button per decade
• Easy-to-read 2-line LCD indicator
• With battery operation
• PNP and NPN sensors can be connected
•Relay output
• Input for keypad locking
• Pulse and time batch controller with
counter and reset input
Pre-selection single
Data storage 5 x 10
Programming keypad-driven menu
Functional safety related parameters
MTTFd 1100 a
Mission Time (T
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Ty p e 2-line, 7-segment LC display with signs
Number of digits 6
Display value digit height 7 mm
Pre-selection digit height 4.5 mm
Key interl ock via external "high" signal
Display interval 0 ... 999999
Decimal point 0 to max 3 fractional digits
Scale factor Refresh cycle of the measured value out-
put
Reset manually or external
Electrical specifications
Operating voltage UBBattery 2 x 3.6 V
Input
Counting frequency max. 30 Hz
Impedance 110 kOhm
Counting method adding or subtracting
Output
Relay normally open contact (max. 60 VA)
Response time < 20 ms
Ambient conditions
Ambient temperature -20 ... 65 °C (-4 ... 149 °F)
Storage temperature -20 ... 60 °C (-4 ... 140 °F)
Relative humidity ≤ 80 % (noncondensing)
Mechanical specifications
Mass 80 g
Dimensions 48 mm x 48 mm x 85 mm
Mounting latch fastener (dimension 50.5 mm x 54.5 mm)
) 10 a
M
6
switching cyclesor 8 years
Display area for the time batch controller: seconds, minutes,
hours
0.1 … 99.9 seconds, programmable
230 V AC/0.5 A; 60 V DC/2 A
Release date: 2016-09-12 13:43 Date of issue: 2016-09-12 110351_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Dimensions
KCY1-6SR-BTimer, Counter
Electrical connection
48
45
15.5 63 3
Te r m i n a l
3145672
No.
1
2
3
4
5
6
7
+3 V DC for terminal 2
Input of push-button lock
Relay contact
Relay contact
AC/DC optocoupler count input
AC/DC optocoupler reset input
Common AC/DC input
for terminals 5 and 6
≥ 10.5
3145672
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2