Pepperl Fuchs KC-LED-96-1T-24VDC Data Sheet

Timer, Counter, Tachometer KC-LED-96-1T-24VDC
Technical data
General specifications
Pre-selection single Data storage EEPROM Programming keypad-driven menu
Functional safety related parameters
MTTFd 330 a
) 10 a
M
B
max. 50 mA
with position display max. 25 kHz
Model Number
KC-LED-96-1T-24VDC
LED display with 24 V
supply voltage
DC
Features
• Counter/Timer/Tachometer
• Extremely bright, large LED indicator
• 1 pre-select value with transistor out­put
• Adding/subtracting via 2 separate in­puts
• PNP and NPN sensors can be con­nected
• Degree of protection IP65 (front only)
Mission Time (T Diagnostic Coverage (DC) 0 %
Indicators/operating means
Ty p e 6-digit 7-segment LED display, red Display value digit height 14 mm Display interval 0.001 s ... 999999 h Decimal point 0 to max 3 fractional digits Accuracy Speed indicator: < 0.1%; timer: < 50 ppm Reset manually or external
Electrical specifications
Fusing 10 30 V DC: T 0.1 A Operating voltage UB10 ... 30 V DC Operating current I
Input
Signal voltage
High 0.6 x Ue ... 30 V DC Low 0 ... 0.2 x Ue
Counting frequency 30 Hz / 60 kHz
Minimum pulse duration 5 ms for reset input Impedance approx. 5 kOhm Counting method adding or subtracting
Ambient conditions
Ambient temperature -20 ... 65 °C (-4 ... 149 °F) non-condensing Storage temperature -25 ... 70 °C (-13 ... 158 °F) Altitude 0 ... 2000 m
Mechanical specifications
Degree of protection IP65 (front) Mass approx. 140 g Dimensions 96 mm x 48 mm x 89.4 mm
Compliance with standards and directi­ves
Directive conformity
EMC Directive 2004/108/EC EN 61000-6-2:2005
Standard conformity
Emitted interference DIN EN 55011:2009, Class B
Release date: 2016-09-12 10:30 Date of issue: 2016-09-12 215124_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Dimensions
KC-LED-96-1T-24VDCTimer, Counter, Tachometer
+0.6
Electrical connection
45
48
92
96
+0.8
21 34567
19
44,9 x 91,9
2
67.1 6,513.8
X2X1
21
Connection assignment X2
Terminal
DC version No. 1
Power supply
0 V DC (GND) 2
Power supply
10 ... 30 V DC
Connection assignment X1
DC version
Terminal No. 1
Optocoupler collector output
2
Optocoupler emitter output
3
SET
4
INP B
5
INP A
6
n.c
7
n.c.
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Release date: 2016-09-12 10:30 Date of issue: 2016-09-12 215124_eng.xml
Loading...