Timer, Counter KC-LCD-48-1R-24VDC
Technical data
General specifications
Pre-selection single
Data storage > 10 years, EEPROM
Programming keypad-driven menu
Indicators/operating means
Ty p e 2-line, 2 x 6-digit LC display with leading sign
Display value digit height 9 mm
Pre-selection digit height 7 mm
Key interlock via "high" potential at "LOCK" input
Decimal point 0 to max 5 fractional digits
Scale factor 0.0001 ... 99.9999
Reset manually or external
Electrical specifications
Fusing 11 … 30 V DC: T 0.2 A
Model Number
KC-LCD-48-1R-24VDC
LCD batch controller with 1 relay output
and 24 V
supply voltage
DC
Features
• Counter/Timer
• Adding/subtracting via 2 separate inputs
• Batch controller with 1 pre-selection
• Easy-to-read, 2-line LCD display with
symbols for indicated pre-selection
and output status
• Display range and preselection range
from -999999 up to 999999
Overflow will be evaluated correctly
up to 1 decade
• PNP and NPN sensors can be connected
• Degree of protection IP65 (front only)
Operating voltage U
Power consumption P0max. 4 W
Input
Connection Counter inputs: A and B
Signal voltage
High 3.5 ... 30 V DC
Low 0 ... 2 V DC
Counting frequency 30 Hz / 5 kHz
Minimum pulse duration Control/reset inputs: static / 1 ms
Impedance 10 kOhm
Count modes
Pulse counter Counting with counting direction (cnt.dir),
Timer Time measurement via GATE input (FrErun),
Output
Relay changeover contact
Switching voltage max. 250 V AC / 110 V DC
Switching current max. 3 A AC/DC, min. 30 mA DC,
Switching power max. 750 VA / 90 W
Mechanical life 2 x 10
Electrical life 5x104 cycles at 3 A
Response time < 15 ms pulse counter
Sensor supply connected power supply is looped through,
Ambient conditions
Ambient temperature -10 ... 50 °C (14 ... 122 °F)
Storage temperature -25 ... 75 °C (-13 ... 167 °F)
Relative humidity ≤ 93 % at 40 °C
Altitude 0 ... 2000 m
Mechanical specifications
Degree of protection IP65 (front)
Mass approx. 117 g
Dimensions 48 mm x 48 mm x 109.8 mm
Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/EC EN 61000-6-2:2005, EN 50295:1999
Standard conformity
Emitted interference DIN EN 55011:2009, Class B
Mech. capacity EN 60068-2-6:2008
Shock and impact resistance EN 60068-2-27:1995
11 ... 30 V DC
B
Control/reset inputs: LOCK, RESET
difference counting (up.dn),
up/down counting (quad),
counter input A: Start, counter input B: Stop (InpA.InpB.),
counter input B: Start/Stop (InpB.InpB.),
7
switching cycles
< 10 ms time counter
max. 50 mA
(noncondensing)
10 … 55 Hz / 1 mm / XYZ
30 min in each direction
100 G / 2 ms / XYZ
3 times in each direction
Release date: 2016-09-12 10:30 Date of issue: 2016-09-12 214735_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Dimensions
KC-LCD-48-1R-24VDCTimer, Counter
48
+0.6
45
Indicators / Operating means
1
2
3
4
48
45
+0.6
45
13.8
91
2.9
max. 10.5
5
1 Current count value
6
7
2 Preset value
3 Indicator preset value (at 9)
4 Reset key
5 Decade keys 1 to 6 /
Keys for programming
6 Run display for timer
8
7 Shows the active output
8 Prog/Mode key
Electrical connection
5
Signal and control inputs
1 Sensor supply voltage
2 GND (0V)
3 INP A (Signal input A)
4 INP B (Signal input B)
5 RESET (Reset input)
6 LOCK (Input Keypad lock)
7 not connected
8 not connected
Supply voltage and outputs
9 not connected
10 not connected
11 Relay contact C.
12 Relay contact N.O.
13 Relay contact N.C.
14 11 ... 30 V DC
15 GND (0V)
Output
Supply
voltage
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.