Technical data
General specifications
Pre-selection single Data storage > 10 years, EEPROM Programming keypad-driven menu
Indicators/operating means
Ty p e 2-line, 2 x 6-digit LC display with leading sign Display value digit height 9 mm Pre-selection digit height 7 mm Key interlock via "high" potential at "LOCK" input Decimal point 0 to max 5 fractional digits Scale factor 0.0001 ... 99.9999 Reset manually or external
Electrical specifications
Fusing T 0.1 A
Model Number
KC-LCD-48-1R-230VAC
LCD batch controller with 1 relay output and 230 V
supply voltage
AC
Features
• Counter/Timer
• Adding/subtracting via 2 separate in­puts
• Batch controller with 1 pre-selection
• Easy-to-read, 2-line LCD display with symbols for indicated pre-selection and output status
• Display range and preselection range from -999999 up to 999999 Overflow will be evaluated correctly up to 1 decade
• PNP and NPN sensors can be con­nected
• Degree of protection IP65 (front only)
Operating voltage U Power consumption P0max. 6.5 VA
Input
Connection Counter inputs: A and B
Signal voltage
High 3.5 ... 30 V DC
Low 0 ... 2 V DC Counting frequency 30 Hz / 5 kHz Minimum pulse duration Control/reset inputs: static / 1 ms Impedance 10 kOhm Count modes
Pulse counter Counting with counting direction (cnt.dir),
Timer Time measurement via GATE input (FrErun),
Output
Relay changeover contact
Switching voltage max. 250 V AC / 110 V DC
Switching current max. 3 A AC/DC, min. 30 mA DC,
Switching power max. 750 VA / 90 W
Mechanical life 2 x 10
Electrical life 5x104 cycles at 3 A
Response time < 15 ms pulse counter
Sensor supply 14.4 ... 27.6 V DC
Ambient conditions
Ambient temperature -10 ... 50 °C (14 ... 122 °F) Storage temperature -25 ... 75 °C (-13 ... 167 °F) Relative humidity 93 % at 40 °C
Altitude 0 ... 2000 m Pollution degree 2
Mechanical specifications
Degree of protection IP65 (front) Mass approx. 230 g Dimensions 48 mm x 48 mm x 109.8 mm
Compliance with standards and directi­ves
Directive conformity
Low Voltage Directive 2006/95/EC EN 61010-1:2001; protection class: 2
EMC Directive 2004/108/EC EN 61000-6-2:2005, EN 50295:1999 Standard conformity
Emitted interference DIN EN 55011:2009, Class B
Mech. capacity EN 60068-2-6:2008
Shock and impact resistance EN 60068-2-27:1995
230 V
B
AC
Control/reset inputs: LOCK, RESET
difference counting (up.dn), up/down counting (quad),
counter input A: Start, counter input B: Stop (InpA.InpB.), counter input B: Start/Stop (InpB.InpB.),
7
switching cycles
< 10 ms time counter
max. 50 mA at 230 V
(noncondensing)
10 55 Hz / 1 mm / XYZ 30 min in each direction
100 G / 2 ms / XYZ 3 times in each direction
AC
Release date: 2016-09-12 10:30 Date of issue: 2016-09-12 214734_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Dimensions
KC-LCD-48-1R-230VACTimer, Counter
48
+0.6
45
Indicators / Operating means
1
2
3
4
48
45
+0.6
45
13.8
91
2.9
max. 10.5
5
1 Current count value
6
7
2 Preset value 3 Indicator preset value (at 9) 4 Reset key 5 Decade keys 1 to 6 / Keys for programming 6 Run display for timer
8
7 Shows the active output 8 Prog/Mode key
Electrical connection
5
Signal and control inputs
1 Sensor supply voltage 2 GND (0V) 3 INP A (Signal input A) 4 INP B (Signal input B) 5 RESET (Reset input) 6 LOCK (Input Keypad lock) 7 not connected 8 not connected
Supply voltage and outputs
9 not connected 10 not connected 11 Relay contact C. 12 Relay contact N.O. 13 Relay contact N.C. 14 230 V AC N~ 15 230 V AC L~
Output
Supply voltage
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.