Pepperl+Fuchs IQT-F116-R4M-V1 User Manual

MANUAL
IQT-F116-R4M-V1
Read/write station (13,56 MHz)
FACTORY AUTOMATION
IQT-F116-R4M-V1
With regard to the supply of products , the current issue of the following document is applicab le: The
General Terms of Delivery for Products and Services of the Electrical Industry, published by the
Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie
(ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation
IQT-F116-R4M-V1
Contents
1 Introduction......................................................................... 4
2 Safety................................................................................... 5
2.1 Symbols relevant to safety ............................................................................ 5
2.2 Intended use ................................................................................................. 5
2.3 General notes on safety ................................................................................. 5
3 Product description ........................................................... 7
4 Installation........................................................................... 8
4.1 Storage and transport ................................................................................... 8
4.2 Unpacking..................................................................................................... 8
4.3 Assembly and connection of the read /write station ...................................... 8
5 Operation............................................................................. 9
5.1 General information on transponders ............................................................ 9
5.2 Command overview ......................................................................................9
5.3 System commands .....................................................................................10
5.4 Read/write commands ................................................................................12
5.5 Legend........................................................................................................14
6 Technical specification .................................................... 15
2012-02
3
IQT-F116-R4M-V1
Introduction

1Introduction

Congratulations
You have chosen a device manufactured by Pepperl+Fuchs. Pepperl+Fuchs develops, produces and distributes electronic sensors and interface modules for the market of automation technology on a worldwide scale.
Before you install this device and put it into operation, please read the operating instructions thoroughly. The instructions and notes contained in this operating manual will guide you step-by-step through the installation and commissioning procedures to ensure trouble-free use of this product. By doing so, you:
guarantee safe operation of the device
can utilize the entire range of device functions
avoid faulty operation and the associated errors
reduce costs from downtime and incidental repairs
increase the effectiveness and operating efficiency of your plant.
Store this operating manual somewhere safe in order to have it available for future work on the device.
After opening the packaging, please ensure that the device is intact and that the package is complete.
Symbols used
The following symbols are used in this manual:
Note!
This symbol draws your attention to important information.
Handling instructions
You will find handling instructions beside this symbol
Contact
If you have any questions about the device, its functions, or accessories, please contact us at:
Pepperl+Fuchs GmbH Lilienthalstraße 200 68307 Mannheim Telephone: +49 621 776-4411 Fax: +49 621 776-274411 E-Mail: fa-info@pepperl-fuchs.com
2012-02
4
IQT-F116-R4M-V1
Safety

2Safety

2.1 Symbols relevant to safety

Danger!
This symbol indicates a warning about an immediate possible danger.
In case of ignoring the consequences may range from personal injury to death.
Warn ing!
This symbol indicates a warning about a possible fault or danger.
In case of ignoring the consequences may cause personal injury or heaviest property damage.
Caution!
This symbol indicates a warning about a possible fault.
In case of ignoring the devices and any connected facilities or systems may be interrupted or fail completely.

2.2 Intended use

The read/write station is intended to identify RFID Transponders in a defined frequency and is only to be used for this purpose.
Read through these instructions thoroughly. Familiarize yourself with the device before installing, mounting, or operating.
Always operate the device as described in these instructions to ensure that the device and connected systems function correctly. The protection of operating personnel and plant is only guaranteed if the device is operated in accordance with its intended use.

2.3 General notes on safety

Only instructed specialist staff may operate the device in accordance with the operating manual.
User modification and or repair are dangerous and will void the warranty and exclude the manufacturer from any liability. If serious faults occur, stop using the device. Secure the device against inadvertent operation. In the event of repairs, return the device to your local Pepperl+Fuchs representative or sales office.
The connection of the device and maintenance work when live may only be carried out by a qualified electrical specialist.
The operating company bears responsibility for observing locally applicable safety regulations.
Store the not used device in the original packaging. This offers the device optimal protection against impact and moisture.
2012-02
Ensure that the ambient conditions comply with regulations.
5
IQT-F116-R4M-V1
Safety
Note!
Disposal
Electronic waste is hazardous waste. When disposing of the equipment, observe the current statutory requirements in the respective country of use, as well as local regulations.
2012-02
6