Pepperl+Fuchs IDM-Z1-160-D-1D-J1-SU-N-N0, IDM-Z1-160-D-1D-J1-SU-P-N0, IDM-Z1-260-D-2D-J1-S1-N-N0 User Manual

IDM-Z1-160-D-1D-J1-SU-N-N0 IDM-Z1-160-D-1D-J1-SU-P-N0 IDM-Z1-260-D-2D-J1-S1-N-N0
Wired handheld scanner for use in explosion-hazardous areas Zone 1/21
Manual
With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietor­ship"
Worldwide
Pepperl+Fuchs Group
Lilienthalstr. 200
68307 Mannheim
Germany
Phone: +49 621 776 - 0
E-mail: info@de.pepperl-fuchs.com
North American Headquarters
Pepperl+Fuchs Inc.
1600 Enterprise Parkway
Twinsburg, Ohio 44087
USA
Phone: +1 330 425-3555
E-mail: sales@us.pepperl-fuchs.com
Asia Headquarters
Pepperl+Fuchs Pte. Ltd.
P+F Building
18 Ayer Rajah Crescent
Singapore 139942
Phone: +65 6779-9091
E-mail: sales@sg.pepperl-fuchs.com
https://www.pepperl-fuchs.com
IDM-Z1-160-D-1D-J1-SU-N-N0, IDM-Z1-160-D-1D-J1-SU-P-N0, IDM-Z1-260-D-2D­J1-S1-N-N0
1 Safety .......................................................................................................................... 4
1.1 Introduction.................................................................................................... 4
1.1.1 Content of this Document .................................................................. 4
1.1.2 Manufacturer...................................................................................... 4
1.1.3 Target Group, Personnel .................................................................... 4
1.1.4 Symbols Used ................................................................................... 5
2 Technical Specifications ........................................................................................... 6
2.1 Explosion protection ..................................................................................... 6
2.2 Technical Data: Handheld Scanner .............................................................. 7
2.3 Use ..................................................................................................................7
3 System Structure....................................................................................................... 8
3.1 Overview......................................................................................................... 8
3.2 IDM-Z1-160-D-1D-J1-* System Structure 1................................................ 10
3.3 IDM-Z1-160-D-1D-J1-* System Structure 2................................................ 11
3.4 IDM-Z1-160-D-1D-J1-* System Structure 3................................................ 12
3.5 IDM-Z1-260-D-2D-J1-S1-N-N0 System Structure 1 ................................... 13
3.6 IDM-Z1-260-D-2D-J1-S1-N-N0 System Structure 2 ................................... 13
3.7 IDM-Z1-260-D-2D-J1-S1-N-N0 System Structure 3 ................................... 14
4 Commissioning........................................................................................................ 16
4.1 Connection of the Wired Handheld Scanners...........................................16
4.2 Supply Module Connection ........................................................................16
4.3 Base connection line RS232....................................................................... 18
4.4 Base connection line USB ..........................................................................19
5 Accessories.............................................................................................................. 21
2019-12
3
IDM-Z1-160-D-1D-J1-SU-N-N0, IDM-Z1-160-D-1D-J1-SU-P-N0, IDM-Z1-260-D-2D­J1-S1-N-N0
1 Safety
1.1 Introduction
1.1.1 Content of this Document
This document contains information required to use the product in the relevant phases of the product life cycle. This may include information on the following:
Product identification
Delivery, transport, and storage
Mounting and installation
Commissioning and operation
Maintenance and repair
Troubleshooting
Dismounting
Disposal
Note
For full information on the product, refer to the further documentation on the Internet at www.pepperl-fuchs.com.
The documentation comprises the following parts:
This document
Datasheet
In addition, the documentation may comprise the following parts, if applicable:
EU-type examination certificate
EU declaration of conformity
Attestation of conformity
Certificates
Control drawings
Instruction manual
Other documents
1.1.2 Manufacturer
Pepperl+Fuchs Group Lilienthalstraße 200, 68307 Mannheim, Germany
Internet: www.pepperl-fuchs.com
1.1.3 Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation, maintenance, and dismount­ing lies with the plant operator.
Only appropriately trained and qualified personnel may carry out mounting, installation, com­missioning, operation, maintenance, and dismounting of the product. The personnel must have read and understood the instruction manual and the further documentation.
Prior to using the product make yourself familiar with it. Read the document carefully.
4
2019-12
IDM-Z1-160-D-1D-J1-SU-N-N0, IDM-Z1-160-D-1D-J1-SU-P-N0, IDM-Z1-260-D-2D­J1-S1-N-N0
1.1.4 Symbols Used
This document contains symbols for the identification of warning messages and of informative messages.
Warning Messages
You will find warning messages, whenever dangers may arise from your actions. It is mandatory that you observe these warning messages for your personal safety and in order to avoid prop­erty damage.
Depending on the risk level, the warning messages are displayed in descending order as fol­lows:
Danger!
This symbol indicates an imminent danger.
Non-observance will result in personal injury or death.
Warning!
This symbol indicates a possible fault or danger.
Non-observance may cause personal injury or serious property damage.
Caution!
This symbol indicates a possible fault.
Non-observance could interrupt the device and any connected systems and plants, or result in their complete failure.
Informative Symbols
Note
This symbol brings important information to your attention.
Action
This symbol indicates a paragraph with instructions. You are prompted to perform an action or a sequence of actions.
2019-12
5
IDM-Z1-160-D-1D-J1-SU-N-N0, IDM-Z1-160-D-1D-J1-SU-P-N0, IDM-Z1-260-D-2D­J1-S1-N-N0
2 Technical Specifications
2.1 Explosion protection
IDM-Z1-160-D-1D-J1-*
II 2G Ex ib IIC T4 Gb
II 2D Ex ib IIIC T135°C Db
IDM-Z1-260-D-2D-J1-*
II 2G Ex ib op is IIB T4 Gb
II 2D Ex ib op is IIIC T135°C Db
Test certificate
IBExU 18ATEX1049 IECEx IBE 18.0008
Manufacturer
Pepperl+Fuchs Group
Lilienthalstraße 200, 68307 Mannheim, Deutschland
info@de.pepperl-fuchs.com
2019-12
6
IDM-Z1-160-D-1D-J1-SU-N-N0, IDM-Z1-160-D-1D-J1-SU-P-N0, IDM-Z1-260-D-2D­J1-S1-N-N0
2.2 Technical Data: Handheld Scanner
IDM-Z1-160-D-1D­J1-SU-N-N0
Description Linear imager 2-D imager
Barcode One-dimensional 1-D
(barcode)
Barcode types Code 39, Code 39 Trioptic, Code 32, Code 93, Code 11, Codabar,
Stack codes - PDF417, MicroPDF417, Code 49, Code 16K,
2-D code types - Data Matrix, QR-
Light source LED, visible red light, 630 nm
Scan frequency 500 Hz 60 Hz
Reading distance 20 mm to 850 mm 30 mm to 400 mm
Code resolution (code-dependent)
Immunity to extrane­ous light
Electrical data
Interfaces RS232 / RS422 / USB RS232 / USB
Feedback
Visual 2x LED (operating state/read confirmation)
Acoustic Beeper / buzzer (can be switched off)
Ambient conditions
Shock resistance 50 drop tests on concrete from a height of 2 m
Operating tempera­ture
Storage temperature -30 °C to +70 °C -40 °C to +70 °C
Relative humidity 95 % non-condensing
Mechanical data
Degree of protection IP65
Dimensions [W x H x D]104 mm x 185 mm x 76 mm
Code 128, GS1-128 / EAN 128, UPC / EAN / JAN (with addition), MSI/Plessey, UK/Plessey, IATA, Interleaved 2 of 5, Standard and Industrial 2 of 5, Matrix 2 of 5, Telepen, GS1 DataBar, Australian Post, China Post, German Post, US Planet, US Postnet, British Post, Intelli­gent Mail, Japan Post, Korean Post, Dutch KIX Post
Approx. 0.076 mm Approx. 0.13 mm
100,000 lx
-20 °C to +50 °C
IDM-Z1-160-D-1D­J1-SU-P-N0
One-dimensional 1-D (Barcode and stack code incl. PDF417)
Composite, Codablock F
IDM-Z1-260-D-2D­J1-S1-N-N0
One-dimensional 1-D & 2-D (Barcode and stack code incl. PDF417)
Code, MicroQR-Code, Aztec, MaxiCode
2.3 Use
2019-12
Weight Approx. 200 g without connection cable
The handheld scanner is a piece of handheld apparatus.
It enables portable recording and direct data transfer in explosion-hazardous areas. The device is specifically modified for use in explosion-hazardous areas of zone 1 and zone 21.
7
IDM-Z1-160-D-1D-J1-SU-N-N0, IDM-Z1-160-D-1D-J1-SU-P-N0, IDM-Z1-260-D-2D­J1-S1-N-N0
3 System Structure
3.1 Overview
The wired handheld scanners and their accessories are presented in the following overview. The handheld scanners can be connected to a Pepperl+Fuchs VisuNet operator workstation. Connection can be either via the external power module or an integrated barrier (applies to Vis­uNet GXP). The data can be transferred via the network interface of the VisuNet operator work­station to a host PC in the safe area.
Alternatively, the handheld scanners can be connected to a PC or a programmable logic con­troller (PLC) with the associated power module and operated as "standalone" units.
2019-12
8
Loading...
+ 17 hidden pages