Comprehensive diagnostics for the fieldbus physical layer
<
Handheld with display and integrated expert system
<
Fieldbus interface Ex ia, FISCO, Entity, and DART
<
For commissioning, online monitoring and troubleshooting
<
For FOUNDATION Fieldbus H1 and PROFIBUS PA
<
Multi-language support
<
Operation in Zone 1/Class I, Div. 1
<
Choice of power options for different operating modes
<
PC software for enhanced interface and data backup
<
Function
The FieldConnex® Fieldbus Diagnostic Handheld FDH‑1 is a comprehensive measurement and commissioning tool. The handheld can be
connected to any point of a segment. Via display and push buttons, FDH‑1 guides the user through many scenarios of testing. FDH‑1 can record
and store data for up to 32 segments with maximum device count without requiring a connection to a PC.
FDH‑1 supports inexperienced and expert users alike through different operating modes. Failure margin checks and device coupler tests help set
up the optimum condition of the fieldbus infrastructure and find weak spots in the installation. The expert system and wizards enable easy
handling and require little or no training. FDH‑1 supports multiple languages that can be downloaded onto the handheld.
FDH‑1 Manager Software Premium can operate the handheld with enhanced visualization. The software loads data from FDH‑1 and saves data
back, to allow for comparisons between actual and planned physical layer attributes.
Connection
Technical Data
General specifications
Design / MountingHandheld/mobile
Supply
ConnectionFieldbus , Battery , 9V 6LR61 block, type alkaline, carbon-zinc, lithium iron disulfide,
Fieldbus interface
Fieldbus typeFOUNDATION Fieldbus/PROFIBUS PA
Rated voltageU
Rated currentI
Indicators/operating means
Release date: 2021-01-12 Date of issue: 2021-01-12 Filename: 250382_eng.pdf
N
nickel-cadmium, nickel-metal hydride, or rechargeable lithium , USB
8.5 ... 35 V
N
... 10 mA , if bus powered
1
Fieldbus Diagnostic HandheldFDH-1
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Description:
1 FDH-1 keypad with 8 keys
2 FDH-1 LC display 128 x 64 pixels
3 Fold-out hook for positioning on the desk or hanging
4 Trigger output for external oscilloscope
5USB port
6Bus connection
135
197
40.7
138.3
1
3
45
6
2
All dimensions without tolerance indication
Scope of Delivery
Additional Information
FDH-1
• FDH-1 fieldbus diagnostic handheld
• Transport case
• Fieldbus cordset with 3 pin test plugs, order code ACC-FDH-CBUSC
• Fieldbus cordset with 3 test clips, order code ACC-FDH-CBUSP
• USB 2.0 cable
• FDH-1 Manager Software
Additional Information
Functional Overview of FDH-1
Pre-commissioningFDH-1 checks:
– Installed cables for fieldbus suitability
Segment commissioning and
troubleshooting
Release date: 2021-01-12 Date of issue: 2021-01-12 Filename: 250382_eng.pdf
– Insulation levels and ground faults
The commissioning wizard with automated segment check procedures reports and stores
comprehensive physical layer measurements. The wizard detects or measures, e. g.:
– Physical layer attributes and compares actual setup against planned setup
– Over- and undertermination
Commissioning reports can be uploaded for backup, storage, and documentation.
External oscilloscope can be triggered on fieldbus-specific events via separate output.
4
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".