Pepperl Fuchs FDH-1 User manual

Fieldbus Diagnostic Handheld

®
BusTrig.
USB
Diagnosis/Alarm
-
+S
Battery
+
FDH
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
pa-info@de.pepperl-fuchs.com
Fieldbus Diagnostic Handheld

FDH-1

Comprehensive diagnostics for the fieldbus physical layer
<
Handheld with display and integrated expert system
<
Fieldbus interface Ex ia, FISCO, Entity, and DART
<
For commissioning, online monitoring and troubleshooting
<
For FOUNDATION Fieldbus H1 and PROFIBUS PA
<
<
Operation in Zone 1/Class I, Div. 1
<
Choice of power options for different operating modes
<
PC software for enhanced interface and data backup
<

Function

The FieldConnex® Fieldbus Diagnostic Handheld FDH1 is a comprehensive measurement and commissioning tool. The handheld can be connected to any point of a segment. Via display and push buttons, FDH1 guides the user through many scenarios of testing. FDH1 can record and store data for up to 32 segments with maximum device count without requiring a connection to a PC. FDH1 supports inexperienced and expert users alike through different operating modes. Failure margin checks and device coupler tests help set up the optimum condition of the fieldbus infrastructure and find weak spots in the installation. The expert system and wizards enable easy handling and require little or no training. FDH1 supports multiple languages that can be downloaded onto the handheld. FDH1 Manager Software Premium can operate the handheld with enhanced visualization. The software loads data from FDH1 and saves data back, to allow for comparisons between actual and planned physical layer attributes.

Connection

Technical Data

General specifications
Design / Mounting Handheld/mobile
Supply
Connection Fieldbus , Battery , 9V 6LR61 block, type alkaline, carbon-zinc, lithium iron disulfide,
Fieldbus interface
Fieldbus type FOUNDATION Fieldbus/PROFIBUS PA
Rated voltage U
Rated current I
Indicators/operating means
Release date: 2021-01-12 Date of issue: 2021-01-12 Filename: 250382_eng.pdf
N
nickel-cadmium, nickel-metal hydride, or rechargeable lithium , USB
8.5 ... 35 V
N
... 10 mA , if bus powered
1
Fieldbus Diagnostic Handheld FDH-1
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
pa-info@de.pepperl-fuchs.com

Technical Data

Display LC display
Keypad Membrane 8 keys
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013
Standard conformity
Electromagnetic compatibility NE 21:2011
Degree of protection IEC 60529
Shock resistance EN 60068-2-27
Vibration resistance EN 60068-2-6
Software
Languages English (default), German (optional), Portuguese (optional),
Ambient conditions
Ambient temperature -20 ... 50 °C (-4 ... 122 °F)
Storage temperature -20 ... 70 °C (-4 ... 158 °F)
Relative humidity < 95 % non-condensing
Shock resistance 15 g , 11 ms
Vibration resistance 1 g , 10 ... 150 Hz
Mechanical specifications
Connection type Fieldbus: Cable with test clips and cable with test plugs, 2.5 mm
Degree of protection IP44
Mass 500 g
Data for application in connection with hazardous areas
EU-Type Examination Certificate ZELM 14 ATEX 0531
Marking 1 II 2(1) G Ex ib [ia Ga] IIC T4 Gb ,
Bus
Type Fieldbus
Type of protection ia, ib
Internal capacitance C
Internal inductance L
Voltage U
i
Bus
Type Fieldbus
Type of protection ic
Internal capacitance < 1.8 F
Internal inductance < 1.5 µH
Voltage U
i
Outputs
Type Trigger output
Maximum safe voltage U
Interface
Type USB interface
Maximum safe voltage U
Voltage U
i
Directive conformity
Directive 2014/34/EU EN 60079-0:2012 , EN 60079-11:2012
International approvals
CSA approval CSA 16.70029275
Approved for Class I, Division 2, Groups A, B, C, D T4
Release date: 2021-01-12 Date of issue: 2021-01-12 Filename: 250382_eng.pdf
Trigger output: Cable with 2 banana plugs USB: Square type B socket
1 II 3(1) G Ex ic [ia Ga] IIC T4 Gc , 1 II 3 G Ex ic IIC T4 Gc , 1 II (1 D) [Ex ia IIIC Da] , 1 II (3 D) [Ex ic IIIC Dc]
< 1.8 nF
i
< 1.5 µH
i
30 V
35 V
140 V
m
253 V
m
6 V
Associated equipment for Class I, Division 1
2
Fieldbus Diagnostic Handheld FDH-1
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
pa-info@de.pepperl-fuchs.com

Technical Data

IECEx approval IECEx ZLM 14.0012
Approved for Ex ib [ia Ga] IIC T4 Gb ,
General information
Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and
Ex ic [ia Ga] IIC T4 Gc , Ex ic IIC T4 Gc , [Ex ia IIIC Da] , [Ex ic IIIC Dc]
instructions have to be observed where applicable. For information see www.pepperl­fuchs.com.

Assembly

Accessories

Release date: 2021-01-12 Date of issue: 2021-01-12 Filename: 250382_eng.pdf
ACC-FDH-CTRG FDH-1 Accessory, Trigger Output Cable
FDH-SW-P FDH-1 Manager Software, Premium License
3
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
pa-info@de.pepperl-fuchs.com
Fieldbus Diagnostic Handheld
Dimensions and Assembly
Description: 1 FDH-1 keypad with 8 keys 2 FDH-1 LC display 128 x 64 pixels 3 Fold-out hook for positioning on the desk or hanging 4 Trigger output for external oscilloscope 5USB port 6Bus connection
135
197
40.7
138.3
1
3
4 5
6
2
All dimensions without tolerance indication
Scope of Delivery
Additional Information
FDH-1
• FDH-1 fieldbus diagnostic handheld
• Transport case
• Fieldbus cordset with 3 pin test plugs, order code ACC-FDH-CBUSC
• Fieldbus cordset with 3 test clips, order code ACC-FDH-CBUSP
• USB 2.0 cable
• FDH-1 Manager Software
Additional Information
Functional Overview of FDH-1
Pre-commissioning FDH-1 checks:
– Installed cables for fieldbus suitability
Segment commissioning and troubleshooting
Release date: 2021-01-12 Date of issue: 2021-01-12 Filename: 250382_eng.pdf
– Insulation levels and ground faults
The commissioning wizard with automated segment check procedures reports and stores comprehensive physical layer measurements. The wizard detects or measures, e. g.:
– Physical layer attributes and compares actual setup against planned setup – Over- and undertermination
Commissioning reports can be uploaded for backup, storage, and documentation.
External oscilloscope can be triggered on fieldbus-specific events via separate output.
4
Germany: +49 621 776 2222Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0002 Singapore: +65 6779 9091
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
pa-info@de.pepperl-fuchs.com
Fieldbus Diagnostic Handheld
FDH-1
Expert system An expert system interprets the raw physical layer measurement data. The system
translates the data into easy-to-follow messages that describe causes of faults and suggest steps for corrective actions.
Device coupler output test Function for testing short circuit current limitation for device coupler outputs and measuring
the maximum current.
Failure Margin Test Function for testing the resistance of each node against adverse signal quality. FDH-1
alters signal level, noise and jitter to determine the maximum levels at which communication still operates.
Online monitoring Connection to any part of the segment including intrinsically safe circuits is possible for
quick checks during operation.
FDH-1 automatically creates a live list with address, tag, manufacturer, and device type.
Data storage and history Upload of history recordings to FDH-1 Manager software enables comparison at a later
time for best practices in plant upkeep. (Premium edition only)
Supported measurements (selection)
– Ground faults and unbalance – Signal level –Jitter – Signal polarity –Noise – Communication error statistics
FDH-1 power options during operation
– Fieldbus –USB – Internal battery
Additional Features of the FDH-1 Manager Software
Features Basic
Edition
Fieldbus oscilloscope Visual tool for the fieldbus expert to display the signal
xx
waveform and support for finding tricky faults.
Additional trigger functionality for oscilloscope x
Documentation and comparison
Upload of commissioning records for backup, storage, and documentation.
xx
Upload and comparison of history recordings with online measurements
Download of specific and customized data records for comparison
Configuration Multi-language support x
Premium Edition
x
x
Release date: 2021-01-12 Date of issue: 2021-01-12 Filename: 250382_eng.pdf
5
Loading...