EPV-6000 Vent
EPV 6000 Vent
Features
• Maximum enclosure size 450 ft3 (12.7 m3)
• Pressure relief vent with flow and pressure monitoring at the
exhaust
• Universal mounting in any orientation
• 6000 Control Unit supports 2 vents
• Different vents for different applications
Function
The EPV-6000 vent exhausts excess pressure from the
enclosure and measures flow and pressure during operation.
The 6000 series vent has a pressure transducer and thermal
flow sensor that is connected to the 6000 EPCU. It is
intrinsically safe through the galvanic isolation barrier within
the 6000 EPCU.
Because measurement of the flow is always at the exhaust of
the pressurized enclosure, the vent is located on the
enclosure(s) such that it is venting to the atmosphere.The
EPV-6000 vent can be mounted vertically or horizontally and
is not gravity dependent.
The EPV-6000 vent can be mounted externall or internally to
the enclosure. When mounting internally, only the vent cap is
exposed to the outside atmosphere.
Assembly
Ring nut (Varies)
Seal
reference port
M12 MDC 4-position
connector
Connection
1
2
3
4
EPV-6000-**-** Cordset, M12, 4-pin, shielded 6000 Control Unit
Release date 2019-08-19 23:20 Date of issue 2019-08-19 514686_eng.xml
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Pepperl+Fuchs Group
+
A
–
B
1
1
2
2
4
3
4
3
BN (+)
WH (A)
BU ()
BK (B)
1

Technical data EPV 6000 Vent
General specifications
Series 6000 Series
Number of volume exchanges 4 to 19
Hazardous environment gas, dust, gas and dust
Electrical specifications
Connection
Power Intrinsically Safe back to 6000 control unit
Signal BUS back to 6000 control unit
Connection M12 connector, 4-pin
Indicators/settings
LED indication power: green
Pneumatic parameters
Protective gas supply instrument grade air or inert gas
Safe pressure Gas: 0.25" wc (6.4 mm wc) (0.625 mbar) (62 Pa)
Enclosure pressure 0 ... 9.9" wc (25 mbar) (250 mm wc)
Max. enclosure pressure 25" wc (62 mbar) (625 mm wc)
Purge flow rate Maximum flow rate measurement for enclosure size (enclosure volume:flow rate):
Purge flow and enclosure pressure rate With EPV-6000-xx-01, EPV-6000-xx-02
vent number: yellow, on for second vent
Dust: 0.65" wc (16.5 mm wc) (1.6 mbar) (162 Pa)
Gas and Dust: 0.65" wc (16.5 mm wc) (1.6 mbar) ( 162 Pa)
< 20 ft³ (0.57m³): 5, 12 SCFM (56, 141, 340 l/min), or dynamic
20 ... 30 ft³ (0.57 ... 0.85 m³): 5, 12, 20 SCFM (56, 141, 340, 565 l/min), or dynamic
> 30 ft³ (0.85m³): 5, 12, 20, 30 SCFM (56, 141, 340, 565, 850 l/min), or dynamic
5 SCFM @ 1.5" wc, (141 l/min @ 3.7 mbar)
12 SCFM @ 2.0" wc, (340 l/min @ 5.0 mbar)
20 SCFM @ 2.7" wc, (565 l/min @ 6.7 mbar)
30 SCFM @ 4.1" wc, (850 l/min @ 10.2 mbar)
With EPV-6000-xx-03, EPV-6000-xx-04
5 SCFM @ 2.1" wc, (141 l/min @ 5.2 mbar
12 SCFM @ 2.6" wc, (340 l/min @ 6.5 mbar)
20 SCFM @ 4.1" wc, (565 l/min @ 10.2 mbar)
30 SCFM @ 5.3" wc, (850 l/min @ 13.2 mbar)
With EPV-6000-xx-05, 06
5 SCFM @ 1.8" wc, (141 l/min @ 4.5 mbar)
12 SCFM @ 2.9" wc, (340 l/min @ 7.3 mbar)
20 SCFM @ 7.4" wc, (565 l/min @ 18.5 mbar)
Flow rate for leakage compensation Depends on enclosure seal.
With EPV-6000-xx-01, EPV-6000-xx-02
0.35 SCFM @ 0.25" wc (10.0 l/min @ .63 mbar)
1.0 SCFM @ 0.75" wc (28.0 l/min @ 1.9 mbar)
With EPV-6000-xx-03, 04
0.22 SCFM @ 0.25" wc (6.2 l/min @ .63 mbar)
0.58 SCFM @ 0.75" wc (16.4 l/min @ 1.9 mbar)
With EPV-6000-xx-05, 06
0.15 SCFM @ 0.25" wc (4.2 l/min @ .63 mbar)
0.35 SCFM @ 0.75" wc (10.0 l/min @ 1.9 mbar)
Breaking pressure EPV-6000-xx-01, EPV-6000-xx-02: 0.8" wc (2.0 mbar)
EPV-6000-xx-03, EPV-6000-xx-04: 1.3" to 1.4" wc (3.2 to 3.5 mbar)
EPV-6000-xx-05, EPV-6000-xx-06: 1.4" to 1.5" wc (3.5 to 3.8 mbar)
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -30 ... 80 °C (-22 ... 176 °F)
Relative humidity 5 ... 95 %, noncondensing
Vibration resistance 5 ... 100 Hz , 1 g, 12 m/s2, all axes
Impact resistance 30 g, 11 ms, all axes
Mechanical specifications
Material EPV-6000-AA-.... Cap: 5052 anodized aluminum, 6061T6 anodized aluminum
EPV-6000-SS-.... Cap: 316L (UNS S31603) stainless steel; Body: 6061T6 anodized aluminum
Spark arrestor 304 (UNS S30400) stainless steel
Installation - any orientation to enclosure
- not gravity dependent
- internal and external mounting possible
Mass approx. 1.4 kg (3.1 lb)
Dimensions 127.5 x 146 x 82.5 mm (5.05 x 5.75 x 3.25 inch)
Release date 2019-08-19 23:20 Date of issue 2019-08-19 514686_eng.xml
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Pepperl+Fuchs Group
2