Capacitive sensor
Model Number
CBN8-F64-E1
Features
•8 mm non-flush
•3-wire DC
•Flat housing
Connection
BN L+
BK
BU L-
<![if ! IE]><![endif]>Release date: 2012-05-29 13:36 Date of issue: 2012-05-29 183178_eng.xml
Subject to modifications without notice
CBN8-F64-E1
Dimensions
|
|
M3 |
|
|
<![if ! IE]> <![endif]>4 |
<![if ! IE]> <![endif]>40 |
|
<![if ! IE]> <![endif]>32 |
|
LED |
16,5 |
6 |
4 |
|
|
|
<![endif]>12
25
Technical Data
General specifications |
|
|
|
|
|
|
|
|
|
|
|
|
Switching element function |
|
|
|
NPN |
NC |
|||||||
Rated operating distance |
sn |
8 mm |
|
|
|
|
|
|
||||
Installation |
|
|
|
non-flush |
||||||||
Output polarity |
|
|
|
DC |
|
|
|
|
|
|
||
Assured operating distance |
sa |
0 ... 6.48 mm |
||||||||||
Nominal ratings |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Installation conditions |
|
|
|
|
|
|
|
|
|
|
|
|
B |
|
|
|
10 mm |
|
|
|
|
|
|
||
C |
|
|
|
20 mm |
|
|
|
|
|
|
||
F |
|
|
|
35 mm / 50 mm |
||||||||
Operating voltage |
UB |
10.8 ... 30 V DC |
||||||||||
Switching frequency |
f |
0 ... 5 Hz |
||||||||||
Hysteresis |
H |
1 ... 10 |
typ. 5 % |
|||||||||
Reverse polarity protected |
|
|
|
reverse polarity protected |
||||||||
Short-circuit protection |
|
|
|
pulsing |
|
|
|
|
|
|
||
Voltage drop |
Ud |
≤ 2 V |
|
|
|
|
|
|
||||
Operating current |
IL |
0 ... 100 mA |
||||||||||
Off-state current |
Ir |
0 ... 0.01 mA typ. |
||||||||||
No-load supply current |
I0 |
≤ 16 mA |
||||||||||
Indication of the switching state |
|
|
|
LED, yellow |
||||||||
Functional safety related parameters |
|
|
|
|
|
|
|
|
||||
MTTFd |
|
|
|
1640 a |
|
|
|
|
|
|
||
Mission Time (TM) |
|
|
|
20 a |
|
|
|
|
|
|
||
Diagnostic Coverage (DC) |
|
|
|
0 % |
|
|
|
|
|
|
|
|
Ambient conditions |
|
|
|
|
|
|
|
|
|
|
|
|
Ambient temperature |
|
|
|
-25 ... 70 °C (-13 ... 158 °F) |
||||||||
Storage temperature |
|
|
|
-25 ... 70 °C (-13 ... 158 °F) |
||||||||
Mechanical specifications |
|
|
|
|
|
|
|
|
|
|
|
|
Connection type |
|
|
|
cable PVC , 2 m |
||||||||
Core cross-section |
|
|
|
0.34 mm2 |
||||||||
Housing material |
|
|
|
Crastin (PBTB) |
||||||||
Sensing face |
|
|
|
Crastin (PBTB) |
||||||||
Protection degree |
|
|
|
IP67 |
|
|
|
|
|
|
||
Compliance with standards and directives |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard conformity |
|
|
|
|
|
|
|
|
|
|
|
|
Standards |
|
|
|
EN 60947-5-2:2007 |
||||||||
|
|
|
|
|
IEC 60947-5-2:2007 |
|||||||
Approvals and certificates |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
UL approval |
|
|
|
cULus Listed, General Purpose |
||||||||
CSA approval |
|
|
|
cCSAus Listed, General Purpose |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
CCC approval |
|
|
|
Products with a maximum operating voltage of ≤36 V do not bear a |
||||||||
|
|
|
|
|
CCC marking because they do not require approval. |
|||||||
Installation conditions |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B |
|
|
|
F |
|
|
|||
metal-free zone |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
sensing face |
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>C |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
support
Copyright Pepperl+Fuchs
1