Magnetic field sensor 40FY26-020
Technical Data
General specifications
Switching element function PNP NO contact
Model Number
40FY26-020
Features
• Hall Effect Sensor
• Door Interrupt Sensor
• Tamper resistant magnetic actuator
Rated operating distance s
Installation non-flush
Output polarity DC
Nominal ratings
Operating voltage UB10 ... 30 V DC
Hysteresis H 5 ... 25 %
Short-circuit protection yes
Vol tag e d rop Ud≤ 2.5 V DC
Repeat accuracy +/- 3 %
Operating current I
Off-state current I
No-load supply current I
Indicators/operating means
LED indicator switchin g state
Electrical specifications
Electrical rating 10 - 30 V DC
Ambient conditions
Ambient temperature -30 ... 85 °C (-22 ... 185 °F)
Mechanical specifications
Connection type cable PVC , 2 m
Core cross-section 0.34 mm
Housing material Pol ycarbo nate
Sensing face Polycarbonate
Degree of protection IP67
Compliance with standards and directives
Stan dard conf ormit y
Sta ndar ds
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
Use either 41FY1 - 6.4 - 15.2 mm or 41FY2 - 7.6 - 19 mm
n
≤ 200 mA
L
≤ 30 mA
r
≤ 40 mA
0
2
EN 60947-5-2:2007
IEC 60947-5-2:2007
Accessories
41FY1
41FY2
Dimensions
LED
Electrical Connection
4 x 2.5
15
74.2
16
62
49.8
4 x ø5.3
6.1
4 x 7.9
1516
Release date: 2015-03-20 22:10 Date of issue: 2015-03-20 450030_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
BN
BK
BU
L+
L-
1