Ultrasonic proximity switch
3RG6114-3GF00-PF |
Compact range M30 K3, |
|
Connector M12 |
|
|
0…10 V, normally open |
|
Stecker M12 |
|
|
Kompaktreihe M30 K3, |
|
|
|
|
0…10 V, Schließer |
|
|
|
3RG6114-3GE00-PF |
Compact range M30 K3, |
|
Connector M12 |
|
|
0…10 V, normally closed |
|
|
|
|
Kompaktreihe M30 K3, |
|
Stecker M12 |
|
|
0…10 V, Öffner |
|
|
|
Size/Bauform |
|
: |
cylindrical M30/zylindrisch M30 |
|
||
Function/Funktion |
|
: |
Diffuse/Taster |
|
||
Operating distance/Schaltabstand |
|
|
|
|
|
|
Sensing range/Erfassungsbereich |
|
: |
600 ... 6000 mm |
|
||
Focusing range/Einstellbereich |
|
: |
600... 6000 mm |
|
||
Adjustment/Einstellung |
|
|
Potentiometer / SONPROG |
|
||
Standard target/Normmessplatte |
|
: |
100 x 100 mm |
|
||
Repeat accuracy/Wiederholgenauigkeit |
R |
: |
+/- 9 mm |
|
|
|
Switching hysteresis/Hysterese |
H |
: |
60 mm |
|
|
|
Rated ultrasonic frequency/ |
|
: |
80 kHz |
|
|
|
Ultraschallnennfrequenz |
|
|
|
|
|
|
Analog output/Analogausgang |
|
|
|
|
|
|
Output voltage/Ausgangsspannung |
|
: |
0 ... 10 V |
|
|
|
Working resistance/Bürde |
|
: |
> 2 kOhm |
|
||
Characteristic/Kennlinie |
|
: |
Rising/steigend |
|
||
Resolution/Auflösung |
|
: |
12 Bit (4095 steps/Schritte) |
|
||
Measuring rate/Meßrate |
|
: |
100 ms (10 Hz) |
|
||
Accuracy/Genauigkeit |
|
: |
+/- 1,5 % |
|
|
|
Power supply voltage/ |
|
|
|
|
|
|
Versorgungsspannung |
|
|
|
|
|
|
Rated operational voltage/ |
Ue |
: |
24 V DC |
|
|
|
Bemessungsbetriebsspannung |
|
|
|
|
|
|
Operating voltage range/ |
UB |
: |
12 ... 30 V DC incl. ripple content / |
|
||
Betriebsspannungsbereich |
|
|
12 ... 30 V DC incl. Restwelligkeit |
|
||
by reduction of operating voltage/ |
|
: |
12 V |
< |
operating voltage |
< 20 V |
bei Betriebspannungsreduzierung |
|
|
12 V |
< |
Betriebsspannung |
< 20 V |
Detection/Erfassung |
|
: |
20 % < |
reduced sensitivity |
< 0 % |
|
|
|
|
20 % < |
reduzierte Empfindlichkeit |
< 0 % |
|
No-load supply current/Leerlaufstrom |
Io |
: |
max. 50 mA |
|
||
max. ripple content/zul. Restwelligkeit |
|
: |
10 % |
|
|
|
Output/Ausgang |
|
|
|
|
|
|
Output/Ausgangsart |
|
: |
pnp |
|
|
|
Rated operational current/ |
Ie |
: |
max. 300 mA |
|
||
Bemessungsbetriebsstrom |
|
|
|
|
|
|
Output voltage drop/Spannungsfall max. |
Ud |
: |
max. 3V (300mA) |
|
||
Off-state current/Reststrom |
Ir |
: |
max. 0,01 mA |
|
||
Short circuit strength/Kurzschlußfestigkeit |
|
: |
built-in/eingebaut |
|
||
Overload withstand capability/ |
|
: |
built-in/eingebaut |
|
||
Überlastfestigkeit |
|
|
|
|
|
|
Subject to modifications without notice |
Release: 09.09.2010 |
Copyright Pepperl+Fuchs |
1
Ultrasonic proximity switch
Bidirectional connection „Release“/
Bidirektionaler Anschluß „Freigabe“
As release input/als Freigabeeingang |
|
|
|
max. input voltage/ |
|
: |
30 V |
max. Eingangsspannung |
|
|
|
max. L-Level (SONAR-BERO inactive)/ |
|
: |
0 ... 3 V |
max. L–Pegel (SONAR-BERO inaktiv) |
|
|
|
min. H-Level (SONAR-BERO active)/ |
|
: |
15 ... 30 V or high-resistance/oder hochohmig |
min. H-Level (SONAR-BERO aktiv) |
|
|
|
Input resistance (current sink)/ |
|
: |
0,9 kOhm |
Eingangswiderstand (Stromsenke) |
|
|
|
min. enable time/min. Freigabezeit |
|
: |
300 ms |
As synchronization connection/ |
|
|
|
als Synchronisieranschluß |
|
|
|
max. quantity of SONAR-BERO run in |
|
: |
10 |
synchronism/ |
|
|
|
max. Anzahl der synchron laufenden |
|
|
|
SONAR-BERO |
|
|
|
Times/Zeiten |
|
|
|
Frequency of operating cycles/ |
f |
: |
1 Hz |
Schaltfrequenz |
|
|
|
Time delay before availability/ |
tv |
: |
280 ms |
Bereitschaftsverzug |
|
|
|
Response time/Ansprechzeit |
|
: |
400 ms |
Temperatures/Temperaturen |
|
|
|
Rated temperature/ |
Tu |
: |
25 Cel |
Bemessungstemperatur |
|
|
|
Ambient temperature/ |
Ta |
: |
-25 ... +70 Cel |
zul. Umgebungstemperatur |
|
|
|
Storage temperature range/ |
Ts |
: |
-40 ... +85 Cel |
zul. Lagertemperatur |
|
|
|
Thermal drift (teach value)/ |
|
|
max. ± 1,5 % |
Temperaturdrift (Toleranzwert) |
|
|
|
Electrical protections/ |
|
|
|
Elektrische Schutzmaßnahmen, EMV |
|
|
|
Reverse voltage protection/ |
|
: |
built-in/eingebaut |
Verpolungsschutz |
|
|
|
Wire breakage protection/ |
|
: |
built-in/eingebaut |
Drahtbruchsicherheit |
|
|
|
Inductive overvoltage/Induktionsschutz |
|
: |
built-in/eingebaut |
False pulses/Einschaltfehlimpuls |
|
: |
suppressed/unterdrückt |
IEC 61000-4-2 |
|
|
4 kV |
IEC 61000-4-3 |
|
|
10 V/m |
IEC 61000-4-4 |
|
|
2 kV |
IEC 61000-4-6 |
|
|
10 V/m |
EN 55011 |
|
|
Class B |
Subject to modifications without notice |
Release: 09.09.2010 |
Copyright Pepperl+Fuchs |
2