Table of Contents
Section 1. Heater Identification Information .......................................................................4
Important Notices .................................................................................................................................................................................5
Warranty Information ............................................................................................................................................................................5
Consumer Information and Safety Information ......................................................................................................................................6 - 8
General Specifications .........................................................................................................................................................................8
Putting the Heater into Service ............................................................................................................................................................9
Water Connections ...............................................................................................................................................................................12
Below Pool Installation .........................................................................................................................................................................12
Gas Connections .................................................................................................................................................................................13
Gas Pipe Sizing ...................................................................................................................................................................................14
Testing Gas Pressure/Gas Pressure Requirements .............................................................................................................................15
Combustion Air Supply .........................................................................................................................................................................19
Corrosive Vapors and Possible Causes ................................................................................................................................................19
Vent Installation (Indoor Installation for U.S. or Outdoor Shelter for Canada) ........................................................................................20
Horizontal or Vertical Venting - Positive Pressure ................................................................................................................................23
Connecting Special Gas Venting ..........................................................................................................................................................23 - 25
Garage or Utility Room Installation .......................................................................................................................................................26
Control Panel Indexing .........................................................................................................................................................................27
Final Installation Check ........................................................................................................................................................................27
Basic System Operation ......................................................................................................................................................................32
To Turn Off Gas to Appliance ...............................................................................................................................................................33
Initial Troubleshooting and Troubleshooting Chart .................................................................................................................................37
Heater Will Not Fire Troubleshooting ....................................................................................................................................................38 - 41
LED Diagnostics ..................................................................................................................................................................................42 - 43
Care and Maintenance ..........................................................................................................................................................................45
After Start-Up ......................................................................................................................................................................................46
Spring, Fall and Winter Operation .........................................................................................................................................................46
Maintaining Pool Temperature ...............................................................................................................................................................47
Energy Saving Tips ..............................................................................................................................................................................47
Chemical Balance ................................................................................................................................................................................ 47 - 48
Replacement Parts .............................................................................................................................................................................. 49 - 53
To identify the heater, see rating plate on the inner front panel of the heater. There are two designators for each
heater, one is the Model Number and the other is the Heater Identification Number (HIN).
a. Heater Identification Number (HIN)
The following example simplifies the identification system:
1) MT : MasterTemp
2) Model Size : (175, 200, 250, 300 or 400) : Input rating (Btu/hr) X 1000
3) Fuel Type : (LP = Propane gas or NA = Natural gas)
4) Construction :(STD = Standard Model)
(HD = Heavy Duty Model)
(ASME = ASME Certified Model)
HEATER IDENTIFICATION INFORMATION — (HIN)
H. I. N.
HEATER IDENTIFICATION NUMBER
ID DESIGNATOR FOR PENTAIR WATER POOL & SPA MASTERTEMP HEATERS
Example:
1 2 3 4
MT250NAASME
STD = STANDARD MODEL
CONSTRUCTION =
FUEL TYPE =
MODEL SIZE = BTU INPUT in 1000 of BTU / HR
HD = HEAVY DUTY MODEL
ASME = ASME CERTIFIED MODEL
NA = NATURAL GAS
LP = PROPANE GAS
P/N 472592 Rev. C 10-5-07
MT = MASTERTEMP
Section 2.Introduction
Introduction
5
MasterTemp
®
Pool and Spa Heater
Congratulations on your purchase of a MasterT emp high performance heating system. Proper installation and service of
your new heating system and correct chemical maintenance of the water will ensure years of enjoyment. The MasterT emp
is a compact, lightweight, efficient, induced-draft, gas fired high performance pool and spa heater that can be directly
connected to schedule 40 PVC pipe. The MasterTemp also comes equipped with the Pentair multifunction temperature
controller which shows, at a glance, the proper functioning of the heater. All MasterTemp heaters are designed with a
direct ignition device, HSI (hot-surface ignition), which eliminates the need for a standing pilot. The MasterT emp requires
an external power source (120/240 VAC 60 Hz) to operate.
SPECIAL INSTRUCTIONS TO OWNER: Retain this manual for future reference. This instruction manual provides
operating instructions, installation and service information for the MasterT emp high performance heater. The information
in this manual applies to all MasterT emp models. READ AND REVIEW THIS MANUAL COMPLETEL Y , it is very
important that the owner/installer read and understand the section covering installation instructions, and recognize the
local and state codes before installing the MasterTemp. Its use will reduce service calls and chance of injury and will
lengthen product life. History and experience has shown that most heater damage is caused by improper installation
practices.
IMPORTANT NOTICES
...For the installer and operator of the MasterT emp pool and spa heater. The manufacturer’s warranty may be void if, for
any reason, the heater is improperly installed and/or operated. Be sure to follow the instructions set forth in this manual.
If you need any more information, or if you have any questions regarding to this pool heater, please contact Pentair W ater
Pool and Spa, Inc. at (800) 831-7133.
WARRANTY INFORMATION
The MasterTemp pool heater is sold with a limited factory warranty. Specific details are described on the warranty
registration card which is included with the product. Return the warranty registration card after filling in the serial
number from the rating plate inside the heater.
Pentair Water Pool and Spa’s high standards of excellence include a policy of continuous product improvement
resulting in your state-of-the-art heater. We reserve the right to make improvements which change the specifications
of the heater without incurring an obligation to update the current heater equipment.
These heaters are designed for the heating of chlorine, bromine or salt system swimming pools and spas or
in non-stationary installations, and should never be employed for use as space heating boilers or general
purpose water heaters. The manufacturer’s warranty may be void if, for any reason, the heater is improperly
installed and/or operated. Be sure to follow the instructions set forth in this manual.
CAUTION
OPERATING THIS HEATER CONTINUOUSLY AT WATER TEMPERATURE BELOW 68° F. WILL CAUSE HARMFUL
CONDENSATION AND WILL DAMAGE THE HEATER AND VOID THE WARRANTY. Do not use the heater to protect
pools or spas from freezing if the final maintenance temperature desired is below 68° F., as this will cause condensation
related problems.
Rev. C 10-5-07 P/N 472592
6
Section 2. Introduction
CODE REQUIREMENTS
Installation must be in accordance with all local codes and/or the latest edition of the National Fuel Gas Code,
ANSI Z223.1/NFPA54 and the National Electrical Code, ANSI/NFP A70 (U.S.), or standards CSA B149 – INST ALLA TION
CODES FOR GAS-BURNING APPLIANCES AND EQUIPMENT and/or local codes and Standard CSA C22.1 –
Canadian Electrical Code, Part 1 (Canada). The heater, when installed, must be electrically grounded and bonded inaccordance with local codes, or, in absence of local codes, with the Canadian Electrical Code or the National Electrical
Code, ANSI/NFPA70, as applicable.
CONSUMER INFORMATION AND SAFETY
WARNING
The U.S. Consumer Product Safety Commission warns that elevated water temperature can be hazardous.
See below for water temperature guidelines before setting temperature.
1. Spa or hot tub water temperatures should never exceed 104° F. A temperature of 100° F. is considered safe for a
healthy adult. Special caution is suggested for young children. Prolonged immersion in hot water can induce hyperthermia.
2. Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to
unconsciousness and subsequently result in drowning.
3. Pregnant women beware! Soaking in water above 100° F. can cause fetal damage during the first three months of
pregnancy (resulting in the birth of a brain-damaged or deformed child). Pregnant women should stick to the 100° F .
maximum rule.
4. Before entering the spa or hot tub, the user should check the water temperature with an accurate thermometer.
Spa or hot tub thermostats may err in regulating water temperatures by as much as 4° F.
5. Persons with a medical history of heart disease, circulatory problems, diabetes or blood pressure problems should
obtain their physician's advice before using spas or hot tubs.
6. Persons taking medication which induce drowsiness, such as tranquilizers, antihistamines or anticoagulants should not
use spas or hot tubs.
Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the heater.
Do not use this heater if any part has been under water. Immediately call a qualified service technician to
inspect the heater and to replace any part of control system and gas control which has been under water.
P/N 472592 Rev. C 10-5-07
WARNING
Section 2. Introduction
7
SAFETY INFORMATION
The MasterTemp® pool heaters are designed and manufactured to provide many years of safe and reliable service when
installed, operated and maintained according to the information in this manual. Throughout the manual, safety warnings and
cautions are identified by the “ “ symbol. Be sure to read and comply with all of the warnings and cautions.
WARNING — FOR YOUR SAFETY
This product must be installed and serviced by a professional service technician, qualified in pool
heater installation. Some jurisdictions require that installers be licensed. Check with your local
building authority about contractor licensing requirements. Improper installation and/or operation
could create carbon monoxide gas and flue gases which could cause serious injury or death. Improper
installation and/or operation will void the warranty.
WARNING —
This heater is equipped with an unconventional gas control valve that is factory set with a
manifold pressure of -.2 inches wc. Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss of life. Installation or service must
be performed by a qualified installer, service agency or the gas supplier. If this control is replaced, it
must be replaced with an identical control.
Do not attempt to adjust the gas flow by adjusting the regulator setting.
WARNING —
WARNING —
WARNING —
Risk of fire or explosion from incorrect fuel use or faulty fuel conversion. Do not try to run a
heater set up for natural gas on propane gas or vice versa. Only qualified service technicians should
attempt to convert heater from one fuel to the other. Do not attempt to alter the rated input or type of
gas by changing the orifice. If it is necessary to convert to a different type of gas, consult your Pentair
dealer. Serious malfunction of the burner can occur which may result in loss of life. Any additions,
changes, or conversions required in order for the appliance to satisfactorily meet the application
needs must be made by a Pentair dealer or other qualified agency using factory specified and
approved parts. The heater is available for use with natural gas or LP (propane) gas only. It is not
designed to operate with any other fuels. Refer to the nameplate for the type of gas the heater is
equipped to use.
• Use heater only with the fuel for which it is designed.
• If a fuel conversion is necessary, refer this work to a qualified service technician or gas supplier
before putting the heater into operation.
Risk of fire or explosion from flammable vapors. Do not store gasoline, cleaning fluids, varnishes,
paints, or other volatile flammable liquids near heater or in the same room with heater.
Risk of explosion if unit is installed near propane gas storage. Propane (LP) gas is heavier
than air. Consult local codes and fire protection authorities about specific installation requirements
and restrictions. Locate the heater away from propane gas storage and filling equipment as specified
by the Standard for the Storage and Handling of Liquefied Petroleum Gases, CAN/CSA B149.2
(latest edition) or ANSI/NFPA 58 (latest edition).
WARNING —
Rev. C 10-5-07 P/N 472592
Risk of fire, carbon monoxide poisoning, or asphyxiation if exhaust venting system leaks.
Only qualified service technicians should attempt to service the heater, as leakage of exhaust
products or flammable gas may result from incorrect servicing.
8
SAFETY INFORMATION, (cont’d.)
WARNING —
Risk of asphyxiation if exhaust is not correctly vented. Follow venting instructions exactly
when installing heater. Do not use a drafthood with this heater, as the exhaust is under
pressure from the burner blower and a draft hood will allow exhaust fumes to blow into the room
housing the heater. The heater is supplied with an integral venting system for outdoor installation.
A vent conversion kit (
in enclosures (Canada) or indoors (U.S.). Use the specified venting, and only the specified venting,
when heater is installed in an enclosure or indoors. In Canada, this pool heater can only be installed
outdoors or in an enclosure that is not normally occupied and has no openings directly into occupied
areas. See
Page 19 for enclosure venting requirements.
See Page 23 for Part Numbers for Conversion Kits) is available for installations
Section 2. Introduction
CAUTION —
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Wiring errors can also destroy the control board.
• Connect heater to 120 or 240 Volt, 60 Hz., Single Phase power only.
• Verify proper operation after servicing.
• Do not allow children to play on or around heater or associated equipment.
• Never allow children to use the pool or spa without adult supervision.
• Read and follow other safety information contained in this manual prior to operating this pool
heater.
GENERAL SPECIFICATIONS
NOTICE:
•Combustion air contaminated by corrosive chemical fumes can damage the heater and will void the warranty.
•The Combination Gas Control Valve on this heater differs from most appliance gas controls. If it must be replaced,
for safety reasons replace it only with an identical gas control.
•The access door panels must be in place to provide proper ventilation. Do not operate the heater for more than five (5)
minutes with the access door panels removed.
•This heater is design certified by CSA International as complying with the Standard for Gas Fired Pool Heaters,
ANSI Z21.56/CSA 4.7, and is intended for use in heating fresh water swimming pools or spas.
•The heater is designed for the heating of chlorine, bromine or salt system swimming pools and spas. It should NOT
be used as a space heating boiler, or general purpose water heater. The heater requires an external 120 or 240 VAC
single-phase electric power source.
•The heater is design certified by CSA International for installation on combustible flooring. Specified minimum
clearances must be maintained to combustible surfaces (see “Heater Clearances”,
•The heater should be located in an area where leakage of the heater or connections will not result in damage to the
area adjacent to the heater or to the structure. When such locations cannot be avoided, it is recommended that a
suitable drain pan, adequately drained, be installed under the heater. The pan must not restrict air flow.
•The heater may not be installed within five feet of the inside surface of a pool or spa unless it is separated by a solid
fence, wall or other permanent barrier.
P/N 472592 Rev. C 10-5-07
page 18).
Section 3.Installation
Gas
Air
Mixer
Blower
Inlet
(Cold
Water)
Exhaust
Heating Coils
Outlet
(Mixed
Water)
Burner
Installation Instructions
HEATER DESCRIPTION
Figure 1 is a diagram of the heater showing how it operates. Precisely
matched orifice plates meter the air and gas into the mixer. The
blower draws the air and gas through the mixer and forces it into
the burner’s flame holder. A sealed heat exchanger surrounds the
flame holder, discharging exhaust gases out the flue.
T wo inch PVC water piping connects directly to the manifold/header
on the heat exchanger using 2" PVC slip unions provided with the
heater . The outer manifold remains cool; no heat sinks are required.
A thermal regulator and an internal bypass regulate the water flow
through the heat exchanger to maintain the correct outlet
temperature. The heater operator control panel board assembly is
located on top of the heater.
SEQUENCE OF OPERATION
9
An electronic temperature sensing thermistor in the manifold
adapter inlet controls the heater operation. When the inlet water
temperature drops below the temperature set on the operating
control, the burner controller supplies power to the combustion
air blower through a series of safety interlocks. The interlocks consist of:
• the pressure switch (PS), which senses that the pump is running,
• the high limit switch (HLS), which opens if the heat exchanger outlet temperature goes above 135° F (57° C), and
• the air flow switch (AFS), which senses the pressure drop across the air metering orifice,
• the automatic gas shut-off (AGS) switch, which opens if the heat exchanger outlet temperature goes above 140° F
(60° C).
• the stack flue sensor (SFS), which shuts down the heater if the flue gas temperature reaches 500° F (260° C).
The air flow switch (AFS) senses the pressure drop across the air metering orifice. As soon as there is suf ficient air flow ,
the AFS closes, closing the circuit to the hot surface igniter (HSI), which ignites the fuel mixture. On a call for heat, the
blower and HSI are energized. In about 20 seconds, the gas valve opens and ignition occurs. The HSI then switches to a
sensing mode and monitors the flame.
The heater is equipped with a digital operating control that enables the user to pre-set the desired pool and spa water
temperatures. The control enables the user to select between pool and spa heating, and features a digital display that
indicates the water temperature.
PUTTING THE HEATER INTO SERVICE
If the heater is installed below the level of the pool, or more than two feet above pool level, the pressure switch setting
should be adjusted. See WATER PRESSURE SWITCH, in the SAFETY CONTROLS Section.
Before putting the heater into service for the first time, follow the instructions under “BEFORE START-UP” (
in the front of this manual. Check for proper operation of the heater by following the steps under “OPERATION
INSTRUCTIONS.”
Figure 1.
page 32)
Damage to equipment caused by improper installation or repair will void the warranty .
Rev. C 10-5-07 P/N 472592
10
Section 3. Installation
SPECIFICATIONS
These installation instructions are designed for use by qualified personnel only , trained especially for installation of this
type of heating equipment and related components. Some states require installation and repair by licensed personnel. If
this applies in your state, be sure your contractor bears the appropriate license. See Figure 2 for Outdoor and Indoor
Installations.
DIMENSIONS IN INCHES
23.02"
(58.5 cm)
16"
(40.6 cm)
28.15"
(71.5 cm)
ELECTRICAL
CONDUIT PORT
32.61"
(82.8 cm)
21.0"
(53.3 cm)
TOPFRONT
EXHAUST SIDE
P/N 472592 Rev. C 10-5-07
16.0"
(40.6 cm)
22.7"
(57.7 cm)
28.2"
(71.6 cm)
Figure 2.
PLUMBING SIDE
5.6"
(14.2 cm)
10.13"
(25.7 cm)
Section 3.Installation
PLUMBING CONNECTIONS
The MasterTemp heater has the unique capability of direct
schedule 40 PVC plumbing connections. A set of bulkhead
fittings is included with the MasterT emp to insure conformity
with Pentair’s recommended PVC plumbing procedure. Other
plumbing connections can be used. See Figure 3 for plumbing
connections.
11
CAUTION
POOL
HEATER
Before operating the heater on a new installation, turn
on the circulation pump and bleed all the air from the
MANUAL
BY-PASS
TO
POOL
GATE
VALVE
FILTER
PUMP
filter using the air relief valve on top of the filter. Water
should flow freely through the heater. Do not operate
the heater unless water in the pool/spa is at the proper
Figure 3.
FROM
POOL
level. If a manual by-pass is installed, temporarily close it
to insure that all air is purged from the heater.
VALVES
When any equipment is located below the surface of the pool or spa, valves should be placed in the circulation piping
system to isolate the equipment from the pool or spa. Check valves are recommended to prevent back-siphoning. Backsiphoning is most likely to occur when the pump stops, creating a pressure-suction differential. Do NOT sanitize the pool
by putting chlorine tablets or sticks into the skimmer(s). When the pump is off, this will cause a high concentration of
chlorine to enter the heater, which could cause corrosion damage to the heat exchanger.
CAUTION
Exercise care when installing chemical feeders so as to not allow back siphoning of chemical into the heater, filters
or pump. When chemical feeders are installed in the circulation of the piping system, make sure the feeder outlet line
is down stream of the heater, and is equipped with a positive seal noncorrosive “Check Valve”, (P/N R172288),
between the feeder and heater.
MANUAL BY-PASS
Where the water flow rate exceeds the maximum 120 GPM, a manual
bypass should be installed and adjusted. After installing the valve, adjust
the valve to bring the flow rate within the acceptable range. Then remove
the valve handle or lock it in place to avoid tampering. See Figure 4.
ledoM)MPL()MPG(.niM*)MPL()MPG(.xaM
571)67(02)454(021
002)67(02)454(021
052)59(52)454(021
003)411(03)454(021
004)251(04)454(021
See page 45 for Pressure Relief Valve Installations.
Rev. C 10-5-07 P/N 472592
Figure 4.
Cool water
Warm water out
wolfdednemmocermumixamehtdeecxetonoD*
.gnipipgnitcennocehtrofetar
Table 1.
1. Set Manual By-Pass Valve.
2. Remove Handle.
Outlet to pool
Inlet to heater
12
Section 3. Installation
WATER CONNECTIONS
3-Way
The heater requires proper water flow and pressure for its
Valve
operation. See Figure 5 for the recommended installation.
The filter pump discharges to the filter, the filter dischar ges
to the heater, and the heater discharges directly to the pool
or spa.
A manual bypass valve should be installed across the heater
when the pump flow exceeds 120 GPM (454 LPM). See
“WATER FLOW RATE” on
page 11- Table 1 for setting of
the manual by-pass valve.
Main
Drain
Pool
Heater
Spa
Make sure that the outlet plumbing from the heater contains
no shut-off valves or other flow restrictions that could prevent
flow through the heater (except for below pool as noted
below , or winterizing valves where needed). T o switch flow
between the pool and spa, use a diverter valve. Do not use
any valve that can shut off the flow. Do not use a shut-off
valve to isolate the heater unless it is below the level of the
From Pool
3-Way
Valve
Figure 5.
pool or spa.
Install the chemical feeder downstream of the heater. Install a chemical resistant one-way check valve between the
heater and the chemical feeder to prevent back-siphoning through the heater when the pump is off.
NOTICE: If the heater is plumbed in backwards, it will cycle continuously. Make sure piping from filter is not reversed
when installing heater.
Connect the heater directly to 2" PVC pipe, using the integral unions provided. Heat sinks are not required. The low
thermal mass of the heater will prevent overheating of the piping connected to the pump even if the heater shuts down
unexpectedly.
Occasionally a two-speed pump will not develop enough pressure on the low speed to operate the heater. In this case, run
the pump at high speed only to operate the heater. If this does not solve the problem, do not try to run the heater. Instead,
correct the installation.
Do not operate the heater while an automatic pool cleaner is also operating. If the circulation pump suction is plugged (for
example by leaves), there may not be adequate flow to the heater. Do not rely on the pressure switch in this case.
Chlorinator
Check Valve
Filter
Pump
3-Way
Valve
BELOW POOL INSTALLATION
If the heater is below water level, the pressure switch must be adjusted. This adjustment must be done by a qualified
service technician.
See following CAUTION before installation.
BELOW OR ABOVE POOL INSTALLATION
The water pressure switch is set in the factory at 3.00 PSI (± 0.75 PSI). This setting is for a heater installed at pool level.
If the heater is to be installed more than 1’ above or below, the water pressure switch must be adjusted by a qualified
service technician. See page 34, Figure 29.
If the heater is installed more than 5’ above the pool or more than 4’ below the pool level, you will be beyond the limits
of the pressure switch and a flow switch must be installed. Locate and install the flow switch externally on the outlet
piping from the heater, as close as possible to the heater. Connect the flow switch wires in place of the water
pressure switch wires.
P/N 472592 Rev. C 10-5-07
CAUTION
FLOW SWITCH
Section 3. Installation
13
GAS CONNECTIONS
GAS LINE INSTALLATIONS
Before installing the gas line, be sure to check which gas the heater has been designed to burn. This is important because
different types of gas require different gas pipe sizes. The rating plate on the heater will indicate which gas the heater is
designed to burn. The tables, shown on
the heater. The table is for natural gas at a specific gravity of .65 and propane at a specific gravity of 1.55.
When sizing gas lines, calculate three (3) additional feet of straight pipe for every elbow used. When installing the gas line,
avoid getting dirt, grease or other foreign material in the pipe as this may cause damage to the gas valve, which may result
in heater failure.
The gas meter should be checked to make sure that it will supply enough gas to the heater and any other appliances
that may be used on the same meter. The gas line from the meter will usually be of a larger size than the gas valve
supplied with the heater. Therefore a reduction of the connecting gas pipe will be necessary. Make this reduction
as close to the heater as possible.
The heater requires a gas supply of not less than 4" (10.2cm) wc and not more than 14" (35.6cm) wc. Gas supply
pressures outside of this range may result in improper burner operation. A minimum flowing or dynamic inlet pressure
(while the heater is running) of 4" (10.2cm) wc is required to maintain input rating with no more than a 2” pressure drop
between static and dynamic. The gas supply must be installed in accordance with the National Fuel Gas Code,ANSIZ223.1, or standard CSA B149.1, Natural Gas and Propane Installation Codes, as applicable and all applicable
local codes. Install a manual shut-off valve and a sediment trap and union located outside the heater panels, see
Do not use a restrictive gas cock. The following minimum gas pipe sizes are recommended for natural gas supply piping,
see Table 2 on page 14. For low pressure LP gas, pipe size may be reduced by 1/4", with a minimum pipe size of 1/2".
Check for compliance with local codes.
page 14, show which size pipe is required for the distance from the gas meter to
Figure 6.
The heater and any other gas appliances must be disconnected from the gas supply piping system during any pressure
testing on that system, (greater than ½ PSI). The heater and its gas connection must be leak tested before placing the
heater in operation. Do not use flame to test the gas line. Use soapy water or another nonflammable method.
NOTE
A manual main shut-off valve must be installed externally to the heater.
WARNING
DO NOT INSTALL THE GAS LINE UNION INSIDE THE HEATER CABINET. THIS WILL VOID YOUR WARRANTY.
SEDIMENT TRAPS
Install a sediment trap and union located outside the
heater panels in accordance with National code
requirements. Do not use a restrictive gas cock. The
sediment trap shall be either a tee fitting with a capped
nipple in the bottom outlet which can be removed for
cleaning, as illustrated in Figure 6, or an other device
recognized as an effective sediment trap. All gas piping
should be tested after installation in accordance with
local codes.
In many Propane gas line installations, the gas supplier and/or installer will utilize a two stage regulation process
where by at the supply tank they will install the first stage gas regulator, which would be at a higher pressure, usually
10 psi. This higher pressure allows for a much longer distance and in a much smaller pipe size. Then within a short
distance of the pool heater, usually around 24 inches, they will install a second regulator, which is the second stage,
and this would be set at the required inlet pressure of the heater.
See “Gas Pressure Requirement Charts”
gniziSepiPsaG"erusserPwoL"owTegatS
HTGNELEPIPTNELAVIUQEMUMIXAM
Table 4.
ledoM.tF05ot0.tF001ot05.tF051ot001
004hguorht571.ni2/1.ni2/1.ni2/1
“RESIDENTIAL”
gniziSepiPsaG"erusserPhgiH"enOegatS
.TF.UCreP.U.T.B0052@ISP01
HTGNELEPIPTNELAVIUQEMUMIXAM
Table 3.
NATURAL
.C.W.ni41tates2egatS
ledoM.tF01ot0.tF02ot01
004hguorht571.ni4/3.ni4/3
GAS 2 STAGE REGULATION
In many Natural gas line installations, the gas supplier and/or installer may utilize a two stage regulation process
where by at the streets main gas supply they will install the first stage gas regulator, which would be at a higher
pressure. This higher pressure is usually set at 2 psi or 5 psi and can be for long distances and in a much smaller pipe
size. Then within a short distance of the pool heater, generally around 24 inches, they will install a second regulator,
which is the second stage. This second stage regulator would be set at the minimum operating pressure for the heater.
For “Natural Gas Pentair Pool Heaters” the minimum is 7 inches W.C.
See “Gas Pressure Requirement Charts”
ledoM.tF05ot0.tF001ot05.tF051ot001
003hguorht571.ni2/1.ni2/1.ni2/1
004.ni4/3.ni4/3.ni
004hguorht571.ni2/1.ni2/1.ni2/1
P/N 472592 Rev. C 10-5-07
.TF.UCreP.U.T.B0001@ISP2
HTGNELEPIPTNELAVIUQEMUMIXAM
.TF.UCreP.U.T.B0001@ISP5
gniziSepiPsaG"erusserPhgiH"enOegatS
4/3
Table 5.
gniziSepiPsaG"erusserPwoL"owTegatS
.C.W.ni7tates2egatS
HTGNELEPIPTNELAVIUQEMUMIXAM
ledoM.tF01ot0.tF02ot01
003hguorht571.ni4/3.ni4/3
004.ni4/3.ni1
.C.W.ni7tates2egatS
004hguorht571.ni4/3.ni1
Table 6.
Section 3. Installation
15
TESTING GAS PRESSURE
Before operating the heater, the heater and its gas connections must be leak tested. Do NOT use an open flame to test
for leaks. Test all gas connections for leaks with soapy water.
The heater and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The heater must be isolated from the gas supply system by closing its individual manual shut-off valve during any pressure
testing of the gas supply at test pressures equal to or less than 1/2 psig (3.5 kPa).
CHECKING THE GAS PRESSURE THROUGH THE COMBINATION GAS CONTROL VALVE
WARNING
Risk of fire and explosion. Improper installation, incorrect adjustment, alteration, service, or maintenance of the Combination
Gas Control Valve can lead to fire or explosion, causing loss of life, personal injury, and/or property damage. If it is necessary
to adjust the gas valve, this must be done by only by a qualified service agency. These instructions are for the use of
qualified service technicians only!
This appliance is equipped with an unconventional gas control valve that is factory set with a manifold pressure of –.2"
(–0.5cm) wc. Installation or service must be performed by a qualified installer, service agency, or the gas supplier . If this
control valve is replaced, it must be replaced with an identical control.
The combination gas
valve incorporates dual
shut-off valves and a
negative-pressure regulator.
For proper operation, the
regulated pressure at the
To Air Flow
Switch
Connection
for Service
To Air Flow
Switch
To Gas
Valve Vent
To Gas
Valve Vent
outlet manifold of the valve
must be –0.2" (–0.5cm) wc
below the reference pressure
at the blower mixer inlet,
and the gas valve ‘VENT’
tap must be connected to the
end cap air orifice as shown
Figure 7.
in
To Low Side of
Differential Pressure Gauge
Pressure Tap
Do not attempt to adjust the gas input by adjusting the regulator setting. The correct gas regulator setting is
required to maintain proper combustion and must NOT be altered.
Ven t
Connection
for Test
To High Side
of Differential
Pressure Gauge
Figure 7.
Pressure Tap
Inlet
The use of Flexible Connectors (FLEX) is NOT recommended unless they are properly sized according to the
supplier recommendations for the heater rating.
GAS PRESSURE REQUIREMENTS
Rev. C 10-5-07 P/N 472592
CAUTION
:ETON.gni
erusserPsaGledoM
telnImumixaM
telnImuminiM
dlofinaM
amrofrepnitluser
larutaNenaporP
.C.WsehcnI
TM4141
TM4 4
TM1.0±2.0-1.0±2.0-
tareposiretaehelihwnekatebtsumsgnidaerllA
lliwffosiretaehelihwedamsgnidaerrostnemtsujdaynA
.smelborpecn
Table 7.
16
Section 3. Installation
OUTDOOR INSTALLATION
(U.S. and Canada)
For heaters located outdoors, using the built-in stackless venting system.
WARNING
Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. Propane is heavier than air. Do not
install the heater using propane in pits or other locations where gas might collect. Consult your local building code officials to
determine installation requirements and specific installation restrictions of the heater relative to propane storage tanks and
filling equipment. Installation must meet the requirements for the Standard for the Storage and Handling of Liquid Petroleum
Gases, ANSI/NFPA 58 (latest edition) in the U.S., or CAN/CSA B149.2 (latest edition) in Canada. Consult local codes and fire
protection authorities about specific installation restrictions.
Locate the heater on a level surface in an open area that is protected from drainage or run-off.
Install the heater in an area where leaves or other debris will not collect on or around the heater.
T o avoid damage to the electronic components in the heater, take care to prevent prolonged exposure
to driving sources of water (such as lawn sprinklers, heavy roof runoff, hoses, etc.). A void operation
in persistent, extreme, moist or salty environments.
In extreme weather, shut down the heater and disconnect the power to it until the weather has
moderated. In areas subject to hurricanes or very high winds, purchase the Bolt Down Bracket Kit,
P/N 460738.
HEATER CLEARANCES – OUTDOOR
For Heater mounting
bolts and clamps,
purchase separately
Bolt Down Bracket Kit,
Part No.
460738.
Lead
Anchor
IMPORTANT!
• In an outdoor installation it is important to ensure water is diverted
from overhanging eves with a proper gutter/drainage system. The heater
must be set on a level foundation for proper drainage.
• This unit shall not be operated outdoors at temperatures below -20o F.
If the heater is located under a roof or deck overhang, there must be at least
three feet (1M) of clearance between the bottom of the overhang and the top of
the heater exhaust vent, see Figure 8. If the heater is under a roof or deck
3 ft. (1 M) or more
overhang, the space around the heater must be open on three sides.
For minimum exhaust vent clearances for building openings, see
Figure 9,
page 17.
In Canada, the heater must be installed with the top of the vent at least 10 feet
(3M) below, or to either side of, any opening into a building.
Orient the heater for convenient access to the water connections and the gas
and electrical connections.
Install the heater at least 18 in. (45 cm) from any property line.
CAUTION
If installing the heater next to or near an air conditioning unit or a heat
pump, allow a minimum of 36 in. between the air conditioning unit
and the heater.
Figure 8.
P/N 472592 Rev. C 10-5-07
Section 3. Installation
OUTDOOR INSTALLATION
SIDE VIEW
4 ft.
Window
17
VENTING GUIDELINES
4'
3'
4'
Property Line
4'
Building
Exhaust Grill
(Vent)
4 ft.
Force
Air Inlet
Check local building codes
for setback requirements.
Vent Termination:
Must be at least 3 ft. above any forced
air inlet located within a 10 ft. radius.
Must be located 4 feet away from the building wall
openings, and at the following distances away from
any door, window, or gravity air inlet:
4 ft. below,
4 ft. horizontally
Figure 9.
Rev. C 10-5-07 P/N 472592
18
p
.
INDOOR VENTING — General Requirements
The heater may be installed as a Category I or Category III appliance.
Section 3. Installation
Vented Appliance (Category I) –
Vertical only
An appliance that operates with a nonpositive vent static pressure and with a vent gas temperature that avoids excessive
condensate production in the vent, see
Vented Appliance (Category III) –
pages 20-22.
Vertical or Horizontal
An appliance that operates with a positive vent static pressure and with a vent gas temperature that avoids excessive
condensate production in the vent, see pages 23-25.
If you are considering connecting this heater to a pre-existing vent system, make sure that the vent system meets the
appropriate venting requirements as given in this manual on
pages 18-27. If not, replace the vent system. DO NOT use
a draft hood with this heater.
The vent pipe must be the same size or larger. The MasterTemp heaters are capable of a 270-degree discharge rotation
and operate with a positive vent static pressure and with a vent gas temperature less than 400° F. The total length of the
horizontal run must not exceed the length that is listed in
table 11 on page 23.
HEATER CLEARANCES — General Requirements
INDOOR INSTALLATION (U.S.) OR OUTDOOR SHELTER (CANADA)
The following clearances must be maintained from combustible surfaces:
TOP ..............................6 in. (15 cm)
EXHAUST SIDE .......... 6 in. (15 cm)
HEADER SIDE ............6 in. (15 cm)
DOOR PANELS† ........6 in. (15 cm)
For service access, it is advisable to allow for
sufficient clearance on at least one door
anel
6 in.
Note (†) For service access it is advisable to allow for sufficient clearance
on at least one door panel. The heater is design certified by CSA International
for installation on combustible flooring. For installation on carpeting, the
heater must be mounted on a metal or wood panel that extends at least
6 in.*
6 in.*
three inches (10cm) beyond the base of the heater. If the heater is installed
in a closet or alcove, the entire floor shall be covered by the panel. On an
outdoor shelter installation, the exhaust discharges into a vent pipe. Orient
the heater so that the vent pipe does not interfere with adjustment of the
operating controls. The control panel located on the top panel can be rotated
6 in.
to any of the three sides of the heater for easy access. However, the
control panel must not be located on the side where the vent is located.
Figure 10.
OUTSIDE VENT COVER REMOVAL
The heater is supplied from the factory with a built-in stackless outside vent for outdoor installation. Remove the outside
vent cover for outdoor shelter installation.
P/N 472592 Rev. C 10-5-07
Section 3. Installation
19
COMBUSTION AIR SUPPLY
For indoor installation, the heater location must provide
sufficient air supply for proper combustion and ventilation
of the surrounding area.
The minimum requirements for the air supply specify that
the room in which a heater is installed should be provided
with two permanent air supply openings; one within
12 inches (30cm) of the ceiling, the other within 12 inches
(30cm) of the floor for combustion air, in accordance with
the latest edition of ANSI Z223.1, or the National Fuel Gas
code, the CSA B149.1, Natural Gas and Propane Installation
Codes, as applicable, and any local codes that may apply ..
These openings shall directly , or through duct, connect to
outdoor air .
Pentair W ater Pool and Spa, Inc. does not r ecommend
indoor installations that do not provide combustion
air from outside the building.
Chemicals should not be stored near the heater installation. Combustion air can be contaminated by corrosive
chemical fumes which can void the warranty.
Corrosive Vapors and Possible Causes
aerAstnanimatnoCylekiL
gnimmiwsdetanirolhC
sapsdnasloop
dnanoitcurtsnocweN
irolhcordyhsahcus
ap,sevisehda
saeragniledomer
.edirolhc
elb,snoitulosevawtnenamreP
srolrapytuaeB
.snobracoroulfro
rostnalpnoitaregirfeR
siniflairtsudnisuoirav
gnih
stnalpgnissecorpdna
.sevisehdanoitcurtsnoc
,sdicA.slacimehcgninaelcapsrolooP
.dicacitairumroc
noitcurtsnoc,stnemecdnaseulG
tniapdna,sehsinrav,stni
dnasexaW.sreppirtshsinravdna
muidosromuiclacgniniatnocsrenaelc
,sehca
snobracorolhcgniniatnocsnaclosorea
,stnemecdnaseulg,sdica,stnaregirfeR
nualdnagninaelcyrD
yrd
saera
Rev. C 10-5-07 P/N 472592
spaosyrdnualro,stnegreted,sehcaelB
srenaelcdnasexaW.enirolhcgniniatnoc
uiclac,enirolhcgniniatnoc
muidosrom
.edirolhc
Table 9.
20
Com
b
ustio
C
r
V
ent Bod
y
y
C
C
Section 3. Installation
VENT INSTALLATION –
(Category I)
Always vent the heater to the outdoors, see Note*.
• Vent it vertically using Type “B” double wall vent connector pipe.
INDOOR INSTALLATION (U.S.) OR OUTDOOR SHELTER (CANADA)
NOTE *: Vent must be at least eight (8) feet away from
nearest vertical surface. Vents extending five (5) feet or
more above the roof must be braced or guyed.
Consult your local code officials for detailed information.
Locate the heater so as to minimize the length of horizontal venting and the number of vent elbows required. Horizontal
vent runs must slope up 1/4" per foot (2cm/M) from the heater to allow exhaust condensate to drain and it is recommended
to have a condensate drain as described in the venting installation instructions.
VERTICAL VENTING
(See
Figures 11, 12 and 13)
Vent the heater vertically in a negative pressure (positive draft) system in
accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or
CSA B149.1, Natural Gas and Propane Installation Codes, and local codes. T ype
“B” Double-wall vent connector is recommended; however single-wall pipe is
- NEGATIVE PRESSURE
lean the Interior Surface
4" x 8" Metal
Flue Collar
Vent Pipe
allowed by the National Fuel Gas Code in some circumstances. Consult your
local code official for detailed information. Do not use a draft hood with this heater .
T o connect a negative pressure metal gas vent to the heater, order the appropriate
Metal Flue Collar from the chart below:
lean and RTV
ralloCeulFlateM.oNtraP
"6x46700-70777
"8x47700-70777
hambe
Flue Collar
This Surface
Figure 11.
1. See Table 10, to determine allowable vent sizes for your heater.NOTICE:
T able 10 is for installations in which the total lateral vent length (that is, the horizontal distance from the flue
collar to the main vertical portion of the vent) is less than 1/2 the total vent height (the vertical distance from the flue collar
to the vent termination) and which have three or less elbows in the system. For venting systems which do not meet these
conditions, consult the National Fuel Gas Code, ANSI Z223.1 (U.S.), or the standards CSA B149.1 and B149.2 (Canada).
Read “VERTICAL VENTING – NEGATIVE PRESSURE” before using this table.
Table 10.
– Permitted Minimum and Maximum Vent Heights By Size and Heater Model
2. Install the metal Flue Collar in the Vent Body of
the heater (located under the outside vent
cover). Fasten the metal Flue Collar to the Vent
Body with two #10 sheet metal screws. Use
high temperature silicone RTV to seal the Flue
Collar to the Vent Body. Before connecting the
metal Flue Collar to the Vent Body, wet a clean
cloth or paper towel with isopropyl alcohol
(rubbing alcohol) and vigorously wipe the socket
of the Vent Body. Immediately wipe the cleaned
surfaces dry with a clean cloth or paper towel.
Repeat for the exterior of the 4" end of the metal
Flue Collar. Attach the metal Flue Collar to the
V ent Body using the RTV supplied with the kit,
following the vent manufacturer’s instructions
(included with kit).
3. Attach the vent pipe to the metal Flue Collar
with sheet-metal screws.
Min. 10 Ft.
6" Minimum
Clearance to
Combustible
Materials
Class B Double Wall
Metal Vent Pipe
Metal Flue
Vent
Body
Collar
21
Listed
Termination
Cap
Storm Collar
Flashing
Firestop
Support Vertical
Vent Pipe so
adapter does not
take weight of
pipe.
WARNING
Risk of fire or asphyxiation if vent is not
assembled according to manufacturer’s
instructions or if vent parts from different
manufacturers are mixed. Vent parts from different
manufacturers ARE NOT interchangeable. Mixing
parts from more than one manufacturer may cause
leaks or damage to vent. When assembling a vent,
pick one manufacturer and be sure that all vent parts
come from that manufacturer and are specified by
the manufacturer for your system. Follow
manufacturer’s instructions, local code requirements,
National Fuel Gas Code requirements (U.S.) or
standards CSA B149.1 and B149.2 (Canada)
carefully during assembly and installation.
Figure 12. – Typical Metal Vent Pipe Installation - U.S.
(Vertical – Negative Pressure)
Listed
Termination
Min. 2 Ft.
(.7 M)
6" (15 cm) Minimum
Clearance to Combustible
Materials
Min. 10 Ft. (3.3 M)
Type B Double Wall
Metal Vent Pipe
Vent
Body
Metal Flue
Collar
Condensate
Drain w/trap
Cap
Storm Collar
Flashing
Firestop
Type B Double Wall
Metal Vent Tee
Support Vertical
Vent Pipe so
adapter does not
take weight of
pipe. Dispose
of condensate
according to
local codes.
Rev. C 10-5-07 P/N 472592
Figure 13. – Typical Metal Vent Pipe Installation - Canada
(Vertical – Negative Pressure)
22
4. Install vent pipe so that it can expand and contract freely as the temperature changes. Support the vent pipe according
to applicable codes and the vent manufacturer’s instructions. Pipe support must allow the vent pipe free movement
out and back, from side to side, or up and down as necessary , without putting a strain on the heater or vent body . Slope
horizontal pipe runs up from the heater at least 1/4" per foot (2cm per meter). Install Listed condensate drains at low
points where condensate might collect. Plumb condensate drains to a drain through hard piping or high temperature
tubing such as silicone rubber or EPDM rubber – do not use vinyl or other low temperature tubing. Follow drain
manufacturer’s installation instructions.
5. Use Listed fire stop for floor and ceiling penetrations. Use Listed thimble for wall penetrations. Use a Listed roof
flashing, roof jack, or roof thimble for all roof penetrations. Do not fill the space around the vent (that is, the clear air
space in the thimble or fire stop) with insulation. The roof opening must be located so that the vent is vertical.
6. Do not run the heater vent into a common vent with any other appliance.
Section 3. Installation
WARNING
Fire Hazard. Do not vent the heater directly into a masonry chimney. Installation into a masonry chimney must use a
chimney liner and must meet the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane
Installation Codes requirements and all local code requirements.
WARNING
Risk of fire, carbon monoxide poisoning, or asphyxiation. It is recommended to use a CO Monitor and Fire Alarm in rooms
that contain gas fired appliances.
P/N 472592 Rev. C 10-5-07
Section 3. Installation
23
HORIZONTAL OR VERTICAL VENTING
- POSITIVE PRESSURE
(See Figures 14, 15, and 16)
(Category III)
V ent the heater either horizontally or vertically using an optional vent adapter of the 4-inch special gas approved Category III
vent pipes. Install the vent pipe in accordance with local codes and the provisions of the National Fuel Gas Code, ANSI
Z223.1 (U.S.), or the standards CSA B149.1, Natural Gas and Propane Installation Codes (Canada), and the vent
manufacturer’s instructions. Do not use a draft hood with this heater. Install the vent according to the vent manufacturer’s
detailed instructions.
Maintain clearance between the vent pipe and combustible surfaces according to the vent manufacturer’s instructions and
code requirements. Do not place any insulating materials around the vent or inside the required clear air space surrounding
the vent. See
T able 1 1 for maximum permissible vent lengths.
NOTE
The allowable vent runs for each vent pipe diameter are different and can not be exceeded.
Each 90-degree elbow reduces the maximum horizontal vent run by 12 feet and each 45-degree elbow in
the vent run reduces the maximum vent run by 6 feet. See the table below for the maximum vent lengths
using 90-degree and 45-degree elbows.
The MasterTemp is a “Category III” appliance and is a forced-draft
pool and spa heater which uses positive pressure to push flue gases
through the vent pipe to the outside. Flue gases under positive pressure
swoblE°09fo.oN)M(teeFnihtgneLmumixaM
may escape into the dwelling with any cracks or loose joints in the
vent pipe, or improper vent installation. The vent pipe must be of a
sealed-seam construction, such as those listed for use with “Category
0)M3.12(.tf07
1)M7.71(.tf85
III Appliances”, and for operating temperatures less than 400° F. Vent
pipe construction will be of UL 1738 approved non-corrosive material,
such as stainless steel, aluminum, galvanized. A condensate trap may
2)M0.41(.tf64
3)M4.01(.tf43
be needed. The use of “Approved” thimbles, roof jacks and/or side
vent terminals are required; and the proper clearances to combustible
materials must be maintained in accordance with type of vent pipe
employed—in the absence of a clearance recommendation by the vent
*
4)M7.6(.tf22
pipe manufacturer, the requirements of the Uniform Mechanical Code
should be met. The ventilation air requirements for the MasterTemp
heater can be found on
18 feet may need to be insulated to reduce condensation related problems
page 19. It is recommended that vent runs over
ehtot”4/1tateltuoehtdrawot
.niardotetasnednoc
and/or the use of a condensate trap in the vent run close to the heater may
be necessary in certain installations such as cold climates. Horizontal vents
3’ (1M) or less in length do not require a condensate tee. The MasterTemp heater is suitable for through-the-wall venting.
Do NOT combine exhaust vent pipes to a common exhaust vent in multiple unit installations. Run separate vent pipes.
CONNECTING SPECIAL GAS VENT TO THE HEATER
Metallic:
1. Order an optional appliance adapter kit,
- Part No. 77707-0086 for Saf-T Vent® or Saf-T Vent® CI.
- Part No. 77707-0087 for Z-Vent.
2. Remove the outside vent cover.
3. Install the Appliance Adapter in the Vent Body of the heater (located under the outside V ent Cover). Before connecting
the Appliance Adapter to the V ent Body , wet a clean cloth or paper towel with isopropyl alcohol (rubbing alcohol) and
vigorously wipe the socket of the Vent Body. Immediately wipe the cleaned surfaces dry with a clean cloth or paper
towel. Repeat for the exterior of the heater end of the Appliance Adapter. Attach the appliance adapter to the vent
body using the adhesive specified by the vent manufacturer, following the vent manufacturer’ s instructions.
Risk of carbon monoxide poisoning if adapter is improperly attached. Mechanical connections (such as screws) can
cause cracking and leaks in the adapter. Do NOT drill holes or use screws to connect the appliance adapter to the heater vent
body. Attach with manufacturer’s specified adhesive.
WARNING
Risk of fire or asphyxiation if vent is not assembled according to manufacturer’s instructions or if vent parts from
different manufacturers are mixed. Vent parts from different manufacturers ARE NOT interchangeable. Mixing parts from
more than one manufacturer may cause leaks or damage to vent. When installing a vent, pick one manufacturer and be sure
that all vent parts come from that manufacturer and are specified by the manufacturer for your system. Follow manufacturer’s
instructions and local and National Fuel Gas Code (U.S.) or CSA B149.1, Natural Gas and Propane Installation Codes
(Canada) requirements carefully during assembly and installation.
4. Install vent pipe so that it can expand and contract freely
as the temperature changes. Support the vent pipe
according to applicable codes and vent manufacturer’s
instructions. Pipe support must allow the vent pipe free
movement out and back, from side to side, or up and
down as necessary , without putting a strain on the heater
or vent body. It is recommended to slope the horizontal
pipe runs up from the heater at least 1/4" per foot (2cm/M).
Install “Approved” condensate drains at low points where
condensate might collect. Plumb condensate drains to a
drain through hard piping or high-temperature tubing such
as silicone rubber or EPDM rubber – do not use vinyl or
other low temperature tubing. Follow drain
manufacturer’s installation instructions.
5. Use an “Approved” firestop for floor and ceiling
penetrations. Use an “Approved” thimble for wall
penetrations. Use an “Approved” roof flashing, roof jack,
or roof thimble for all roof penetrations. Do not fill the
space around the vent (that is, the clear air space in the
thimble or firestop) with insulation. The roof opening must
be located so that the vent is vertical.
6. Vent Termination – Vertical (See
Figures 14 and 15),
for height of vent termination above the roof. Use an
“Approved” vent terminal specified by local and national
codes and your manufacturer’s instructions. A roof
termination must be vertical. In Canada, the Vent Cap
location shall have a minimum clearance of 4 feet (1.2M)
horizontally from electric meters, gas meters, regulators,
and relief openings.
Vent Cap and
Riser Furnished
by Installer
Side
Wall Vent
Vent Cap and
Riser Furnished
by Installer
Chimney or Gas Vent
Heater
Chimney or Gas Vent
Outlet Air
Opening
Inlet Air
Opening
Figure 14.
Outlet Air Opening
7. Make sure entire installation is sealed according to
approved standard.
P/N 472592 Rev. C 10-5-07
Side
Wall Vent
Heater
Inlet Air Opening
Figure 15.
Section 3. Installation
25
Max. 12"
Min. 3"
Vent
Terminatio
At least 7'
above grade
adjacent
to public
walkways
Figure 16.
Vent
Termination
1' Minimum
above snow or
finished grade
(whichever is
higher)
Forced Air
Inlet
4' Min.
4' Min.
4' Min.
Gas Meter
3' Minimum clearance if
horizontal distance to
exhaust opening is less
than 10 feet.
4' Min.
Vent
Terminatio
n
1' Min.
8. Vent Termination – Horizontal
The terminal must be located (U.S. – See
• at least 3" and at most 12" out from the wall (see
Figure 16):
Figure 17), following the vent manufacturer’s instructions
• at least 12" above finished grade or the normally expected snow accumulation level, whichever is higher
• at least 4 feet below or horizontally from, or 1 foot above, any doors or windows or gravity air inlet to a building
• at least 3 feet above any forced air inlet located within 10 feet
• at least 4 feet horizontally from electric meters, gas meters, regulators and relief equipment
• at least 7 feet above grade adjacent to walkways or similar traffic areas
The terminal must be located (Canada – See
Figure 16):
n
• at least 10 feet (3.3M) from any opening into a building
• at least 12" (.3M) above finished grade or the normally expected snow accumulation level, whichever is higher
• at least 4 feet (1.2M) horizontally from electric meters, gas meters, regulators and relief equipment
• at least 7 feet (2.1M) above grade adjacent to walkways or similar traffic areas
Allow at least three feet (1M) vertical clearance over
vent termination when terminating under an overhang
or deck.
Avoid corners or alcoves where snow or wind could
have an effect. Exhaust may affect shrubbery and some
building materials. Keep shrubbery away from
termination. T o prevent staining or deterioration, sealing
or shielding exposed surfaces may be required.
WARNING
Fire Hazard. Do not run the heater vent into a common
vent with any other appliance. Do not run the Special
Gas Vent into, through, or within any active vent such
as a factory built or masonry chimney.
Rev. C 10-5-07 P/N 472592
Metal
Vent
Body
Metal Special
Gas Vent
requires
Appliance
Adapter
Condensate
drain w/Trap
(Optional)
Support
weight
of pipe
Condensate
Te e
Slope at least
1/4" per foot
(2 cm per Meter)
down towards
condensate drain
Listed
Termina
3" (7.6 cm) Min.,
12" (30.5 cm) Max.
Clearanc
l
e
Figure 17.
26
Leave 6 in. (15 cm)
of clear space between
heater and combustible
surface.
Leave 3 ft. (1 m)
or more of clearance
above heater
RAISE AT LEAST
18 in. (46 cm) above floor
to avoid flammable vapors
18 in.
Section 3. Installation
OUTDOOR SHELTER INSTALLATION
In Canada, this pool heater can only be installed outdoors or in an enclosure that is not normally occupied and has no direct
openings into occupied areas.
WARNING
Risk of asphyxiation if exhaust is not correctly vented. Follow venting instructions exactly when installing heater. Do not
use a draft hood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow exhaust
fumes to blow into the room housing the heater. Exhaust venting to the outdoors is required for all outdoor shelter installations.
WARNING
Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. Propane is heavier than air. Do not
install the heater using propane in pits or other locations where gas might collect. Consult your local building code officials to
determine installation requirements and specific installation restrictions of the heater relative to propane storage tanks and
filling equipment. Installation must meet the requirements for the Standard for the Storage and Handling of Liquefied Petroleum
Gases, CAN/CSA B149.2 (latest edition) or ANSI/NFPA 58 (latest edition). Consult local codes and fire protection authorities
about specific installation restrictions.
The heater is design certified by CSA International for installation on combustible flooring; in alcoves; basements; in
closet or utility rooms (in the U.S.).
GARAGE OR UTILITY ROOM INSTALLATION
In Canada, the heater must be installed in a room that is not normally occupied and has no openings
directly to occupied areas.
WARNING
Risk of fire and explosion if installed at floor level in an automotive garage or near gasoline or flammable liquid
storage. Gasoline fumes are heavier than air and will settle to floor level in closed spaces. Gasoline fumes and spilled gasoline
or other volatile liquids (such as some paints and varnishes) will travel across the floor and can be ignited by a gas appliance.
In any utility room or residential garage installation, install the heater with the base at least 18 inches (.5M) above the floor,
see Figure 18. In a garage, install a rail or wall to protect the heater from physical damage by a moving vehicle.
Provide an adequate ventilation air supply (See
Table 8, page 19).
Choose a location that will avoid contamination by chemical fumes.
CAUTION
A Propane (LPG) fired heater must not be installed in a garage in
Massachusetts, by order of the Massachusetts State Fire Marshal. For
more information, call the Massachusetts State Fire Marshal’s office.
NOTICE: Combustion air contaminated by corrosive chemical fumes can
damage the heater and will void the warranty (See Table 9, page 19).
P/N 472592 Rev. C 10-5-07
Figure 18.
Section 3. Installation
CONTROL PANEL INDEXING
27
On an outdoor shelter installation, the exhaust discharges into a vent pipe.
Orient the heater so that the vent pipe does not interfere with adjustment of the
operating controls. The control panel located on the top panel can be rotated to
any of the three sides of the heater for easy access, see
Figure 19.
Top Panel
Door
Access
Panel
1. Remove the bolts from the door panels. Remove both door access panels.
2. Remove the four corner screws that secure the top panel. Lift the top
panel upward to remove the top panel.
3. Rotate the top panel to the desired position located at 90° angles. Note
that the control panel must NOT be located on the side where the vent
is located.
4. Replace the top panel down onto the side panels. Be sure that there are no
Door
Access Panel
wires caught under the panel.
5. Secure the top panel using the four corner screws.
Figure 19.
6. Reattach the door access panels.
FINAL INSTALLATION CHECK
Check that horizontal vent pipe runs slope uniformly at least 1/4" per foot (2cm per meter) to condensate drain(s).
No sags, no dips, no high or low spots.
Check that vent is supported at elbows, tees, and horizontal and vertical runs according to manufacturer’s instructions and
code requirements.
Check that vent supports and wall and ceiling penetrations allow free movements up, down, and sideways without putting
any strains on the heater or vent body.
Check for at least six inch (15cm) free air clearance between the heater vent pipe and combustible materials.
Check that all joints are completely together and sealed.
In Florida, building codes require that the heater be anchored to the equipment pad or platform to
withstand high wind pressures created during hurricanes. A Bolt Down Bracket Kit, P/N 460738, is
available with anchor clamps designed to hold the unit to the equipment pad in high wind conditions.
Installation of the anchor clamps are recommended in all installations and are required in Florida,
For Heater mounting
bolts and clamps,
purchase separately
Bolt Down Bracket Kit,
Part No.
460738.
(See Florida Building Code 301.13).
Lead
Anchor
Rev. C 10-5-07 P/N 472592
28
Section 3. Installation
ELECTRICAL CONNECTIONS
Electrical Rating60 Hz 120 / 240 Volts AC, single phase
Enclose the line to the heater in an approved flexible conduit connected directly to the junction box on the inside of the
access door panel. Line voltage field wiring should be 14 gauge, with a circuit capacity of 15 amps.
CAUTION
This heater is designed to operate at 120 or 240 VAC. It is not recommended to be connected to OR operate on a 208 VAC.
NOTE
• Before making any electrical connections to the power supply, remove the access door panels, open the
control box, remove the 12-pin plugs from their bag, and plug in the correct plug (120 volt or 240 volt).
• If any of the original wiring supplied with this heater must be replaced, installer must supply (No. 18 AWG,
600V, 105° C. U.L. approved AWM low energy stranded) copper wire or it’s equivalent.
CAUTION
The heater ships from the Factory with the 240V plug installed. Installing the 120V plug and then connecting the
heater to 240V line current will immediately destroy the transformer, control board and ignition control module, and
will void warranty. If you install the 240V plug and connect the heater to 120 volts line current, the heater will not
operate.
Please read the boxes headed “IMPORTANT! READ ME FIRST!” on pages 37 and 41 before proceeding.
1. All wiring must be in accordance with all applicable codes.
2. The heater, when installed, must be electrically grounded and bonded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code or the Canadian Electrical Code (as applicable). A bonding
lug is provided on the outside of the panel under the vent for this purpose.
3. Electrical power circuits to the pool heater must follow local codes and National Electrical Code or Canadian Electrical
Code (as applicable).
4. All wiring between the heater and devices not attached to it, or between separate devices which are installed in the
field, must be “Type T” wire rated for 35°C rise.
5. All line voltage wiring shall be enclosed in approved flexible conduit, and shall be securely attached to the field wiring
box located inside the access door panel. The conduit or cable connector at the field wiring box should contain an
insulating bushing or its equivalent to prevent abrasion of the wires as they enter the box.
6. The filter pump should run continuously when the heater is on, and for at least 15 minutes after the heaterturns off. Any switches in the pump circuit (including circuit breakers)
that can disconnect the pump must also disconnect the heater.
7. Do not wire single-pole switches, including protective devices, into a
grounded line. The heater is not sensitive to polarity .
Connect the L1 of the power supply to the black wire, the L2 or neutral
lead to the red wire, and the ground wire to the green wire. A time clock
controlling the filter pump should have a low-voltage Fireman’s Switch
that switches off the heater at least 15 minutes before shutting off the
pump.
Always use crimp type connectors when connecting two wires.
P/N 472592 Rev. C 10-5-07
AC Plug
120 Volt
or
240 Volt
Figure 20.
Section 3. Installation
29
CONNECTION OF FIREMAN’S SWITCH OR REMOTE CONTACT
CAUTION
If, while there is line voltage connected to the heater, you touch either line voltage terminal with any 24VAC wire that
is connected to the control board (including the Fireman’s Switch jumper), you will immediately destroy the control
board and void the warranty.
REMOTE CONTROL CONNECTIONS
1. Switch off power to heater at main circuit breaker panel.
2. Unbolt and remove the access door panels.
3. Open control box cover (see
4a. To connect a 2-Wire Control (such as Pentair’s IntelliTouch or EasyTouch) or a
timer:
- Remove the factory installed jumper from the Fireman’s Switch terminals.
- Connect wires between the Fireman’s Switch terminals on the heater and the
relay. Connect wires from the controller or timer to the Fireman’s Switch.
Controller, timer or relay should be sized to handle 24VAC at 0.5 Amp (because
it will be completing the 24VAC control board circuit on the heater as shown in
Figure 22). DO NOT apply line voltage to the Fireman’s Switch terminals. Use
18 gauge wire with a minimum 3/64” (1.2mm) thick insulation rated for a
temperature rise of at least 105°C.
- Knock-outs are provided to route the wires through
the bottom of the control box and past the junction
box.
4b. To connect a 3-Wire Control:
- Connect wires between the control board terminals
on the heater and the external relays, as shown in
Figure 23. Use at least 2 relays per heater, to allow
for an “OFF setting” on each heater mode. Select
relays that can handle logic level switching. DO NOT
apply line voltage to control board terminals.
- Move jumper (as shown on
external control and to disable the heater membrane
pad’s “Pool ON” and “Spa ON” buttons (the “OFF”
key on the membrane pad remains functional).
- Knock-outs are provided to route the wires through
the bottom and the top of the control box and past
the junction box.
5. Close control box cover.
6. Re-install the access door panels.
T o control heaters that are operated in parallel, connect wiring
at same locations on heater as 2-Wire or 3-W ire Control. It
is imperative that each control circuit is isolated from the
other control circuits, to avoid that current will flow from
one heater to another through the control circuits.
NOTICE: The fuse for the Fireman’ s Switch is a 1.25 Amp
1¼ x ¼” fast blow fuse, which is commonly available.
Figure 21).
Figure 23) to enable
Figure 22.
Figure 21.
BK
O
J6
Y
Y
YY
1
9
FUSE
FUSE
24VAC
W
TRANS
GND
FS
24VAC
24VAC
THERMISTOR
MEMBRANE PAD
CONNECTION
TH
IND
VAL
BK
OPERATING CONTROL
O
ENABLE TOGGLE
DISABLE TOGGLE
TERMINAL BOARD
TRANS
W
W
R
R
Time Clock or Remote
(Purchase Separately –
Supplies Power to
Circulator Pump)
Fireman's Switch
Completes the heater
24 Volt AC Control
Board Circuit.
DO NOT connect this
circuit to Line Voltage!
L1
F1
R
BK
L1
L2
12 Pin
Receptacle
L1
G
GROUND (GND )
GND
24VAC
F
I
R
E
FL
M
A
N
S
X
BO
JUNCTION
TRANS
S
W
I
L2
T
C
H
BM
L2
Rev. C 10-5-07 P/N 472592
30
MASTERTEMP WIRING DIAGRAM
(3-WIRE SYSTEM)
CONNECTION DIAGRAM
AGS Switch
Stack Flue Sensor
Gas Valve
O
O
BL
W
W
Y/W
Y
BL
R
R
External Control Interface Circuit Disabled,
Heater Membrane Pad Enabled
JMP
1
Air Flow Switch
Extra Switch 1
Hi-Limit Switch
Pressure Switch
O
O
PR
PR
PS
HLS
ES1
AFS
AGS
SFS
GAS
OPERATING CONTROL
JMP3
1
External Control Interface
VAL
Spa Line
W
BK
TH
IND
GND
Common Line
Section 3. Installation
Y/R
Y/BL
Y/O
Y/W
Y
Y
Y
Y
Y
BR
BR
FS
24VAC
24VAC
MEMBRANE PAD
CONNECTION
Pool Line
THERMISTOR
J6
Y
NA/LP
Models Only
1
6
Y/BL
Y/W
Y/R
Y/O
YYYYY
JMP
1
External Control Interface Circuit
Enabled, "Pool On" and "Spa On"
Keys Disabled. "OFF" Key on
Membrane Pad Remains Functional
Plug –12 pin
120V – Black
240V – Red
1
12 Position
Receptacle
JUNCTION BOX
Line 1
Line 2
Ground
BK
R
G
GND
24
F1 F2
VAC
DIAGNOSTIC INDICATOR
IGNITION CONTROL
MODULE
S1
S1/
L1
120
L2S2TH IND
240
.
GYGYBK
GY
120 VAC
IGNITER
BK
O
GY
GY
R
W
BK
Y
BL
GY
NOTICE: Touching any 24VAC wire, including
the Fireman's Switch wire, to any 120/240V
terminal while the heater is connected to line
power will immediately destroy the control
board and void the warranty.
VAL G ND
W
GND
YY
24VAC
SEC
Y/W
Y/O
Y/BL
Y/R
Y/W
F
I
BK
BK
BK
W
R
BK
Y
BL
G
GND
L1
F1
R
BLOWER
R
E
FL
M
A
N
S
Y
BK
S
W
I
T
C
H
W
O
W
TRANS
L2
BM
RRW
Replace jumper with
leads to Fireman"s
Switch (field installed)
Figure 23.
P/N 472592 Rev. C 10-5-07
Section 3. Installation
MASTERTEMP ELECTRICAL SCHEMATIC LADDER DIAGRAM
LADDER DIAGRAM
L1L2
L1
120/240
VAC
IGNITER
S1S2L2
31
24V
COM NO
F1
24 VAC
F2BLOWER
120/240
VA
C
24 VAC
OPERATING
CONTROL
24 VAC
LOGIC
WATER
PRESSURE
SWITCH
HI
LIMIT
SWITCH
GND
CLASS II
TRANSFORMER
GND
AIR
FLOW
SWITCH
IND
TH
THERMISTOR
Rev. C 10-5-07 P/N 472592
AGS
SWITCH
VAL
STACK FLUE
SENSOR
SENSOR
NOTES:
1.)
L1 L2 F1 F2 S1 24 VAC
S2 GND IND VAL
AND TH
ARE CONNECTED ON THE IGNITION MODULE.
2. )
PIN AND SOCKET CONNECTOR.
3. )
IF ANY OF THE ORIGINAL WIRES AS SUPPLIED
WITH THE APPLIANCE MUST BE REPLACED,
THEY MUST BE REPLACED WITH TYPE 105˚ C
OR ITS EQUIVALENT.
GAS VALVE
Figure 24.
32
Section 4. Operation
Operation Instructions
BASIC SYSTEM OPERATION
Start pump, make sure the pump is running and is primed, to close the water pressure switch and supply
power to heater. Be sure the pool and/or spa is properly filled with water. Follow the Lighting/Operating instructions
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal
injury or loss of life.
Do not attempt to light the heater if you suspect a gas leak. Lighting the heater can result in a fire or explosion
which can cause personal injury, death, and property damage.
START-UP AND OPERATION
START-UP AND SHUTDOWN INSTRUCTIONS ARE ON THE LABEL ATTACHED TO THE COVER OF THE APPLIANCE
CONTROL BOX.
BEFORE START-UP
A. This appliance does not have a pilot. It is equipped with
an ignition device which automatically lights the burners.
Do not try to light the burners by hand.
B. BEFORE OPERATING, smell all around the
appliance area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle on
the floor.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use any phone
in your building.
– Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
– If you cannot reach your gas supplier, call the Fire
Department.
C. Use only your hand to turn the gas control on or off.
Never use tools. If you cannot change the ON/OFF
setting by hand, don't try to repair it, call a qualified
service technician. Forced or attempted repair may result
in a fire or explosion.
D. Do not use this heater if any part has been under water.
Immediately call a qualified service technician to inspect
the heater and to replace any part of the control system
and any gas control which has been under water.
E. Do not operate the pool heater unless the pool or spa is
properly filled with water .
F. Before operating the appliance for the first time or after
it has been off for an extended time, perform the
following checklist:
1. Remove debris or other articles from inside the heater
and the area around the heater and its exhaust vent.
Make sure the ventilation openings are clear of debris
or obstruction. For installations in an enclosed space,
make sure openings for combustion and ventilation
air are unobstructed.
2. Keep heater area clear and free from combustibles,
flammable liquids and chemicals.
3. Check that all water connections are tight.
4. Water must be flowing through the heater during
operation. Make sure that pool/spa is filled with water
and have pump operating. Check that water flow is
unobstructed from the appliance. When operating for
the first time or after an extended shut-down, run
filter pump for several minutes to clear all air from
the system.
P/N 472592 Rev. C 10-5-07
Section 4. Operation
OPERATING INSTRUCTIONS
33
1. STOP! Read the safety information on (page 32).
2. Set both pool and spa thermostats to the lowest settings.
Water
Pressure
Switch
3. Turn off all electric power to the appliance.
4. This appliance does not have a pilot. It is equipped with an ignition device
which automatically lights the burner. Do not try to light the burner by hand.
5. Remove the access door panels by unfastening the four screws located on
each door, then lift up and out from the bottom of the panel to remove. If
necessary, the screws may be used as handles, see
6. Toggle-Style Valve: Pull toggle toward you to turn gas off , see
Figure 25.
Figure 26.
Figure 25.
7. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP!
Follow “B” in the “Before Start-up” instructions (
page 32). If you don’t smell
gas, go to the next step.
8. Push the toggle switch away from you to switch the gas on.
9. Replace the Door Access Panels. All panels must be in place when operating
the heater.
Gas control is shown
OFF. Push toggle
switch away from you
to switch ON.
10. Set 3-way valves on inlet and outlet to pool or spa, as appropriate.
1 1 . Turn on all electric power to the appliance.
12. Press either the POOL ON or SPA ON button switch on the operating control.
13. Set the thermostat to desired setting (NOTICE: Setpoint must be above
actual water temperature or burner will not fire). See “OPERATING the
CONTROL PANEL”.
You
are
here.
14. The blower should come on immediately, and after about 20 seconds, the
burner should fire. When operating for the first time, the burner may not fire
on the first try because of air in the gas line. If it does not fire at first, push the
OFF switch, wait five minutes, and again push the POOL or SPA ON switch.
The burner should fire after about 20 seconds. You may have to repeat this
until all of the air has cleared the gas line.
Figure 26.
15. The burner should fire until the pool/spa temperature reaches the desired temperature set on the thermostat. The
blower will continue to run for about 45 seconds after the burner shuts off. If any of the safety interlocks should open
during burner operation, the burner shuts off immediately, but the blower continues to run for about 45 seconds.
Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.
16. If the appliance will not operate, follow the instructions below “TO TURN OFF GAS TO THE APPLIANCE”, and
call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1. Press the OFF button on operating control.
2. Switch off all electric power to the unit.
3. Remove the access door panels, see
4. Toggle-Style Valve: Pull toggle toward you to turn gas off, see
5. Replace the Access Door Panels.
Rev. C 10-5-07 P/N 472592
Figure 25.
Figure 26.
34
SAFETY CONTROLS
AIR FLOW SWITCH (AFS)
The air flow switch, (see Figure 27), is a safety device used to insure that the
combustion air blower (fan) is operating and has been designed to monitor the
vacuum (negative) pressure within the blower housing. The air flow switch is
factory set and is connected upstream of the ignition module. The ignition module
does not operate unless the air pressure switch and all safety switches are
closed.
WATER PRESSURE SWITCH
WARNING
Section 4. Operation
Figure 27.
Air Flow Switch
Hazardous pressure. Do not bypass the Water Pressure Switch or render
it inoperable.
The water pressure switch, (see Figure 28). If the water flow is restricted, the
water pressure switch may prevent the burner from firing and cause the “Service
System” light to go on. If the light remains on after the filter has been serviced,
have a qualified service technician check the system.
For deck-level heater installations, the Water Pressure Switch is factory set at
3.00 psi (20.6 kPa). NOTE: See, Below Pool Level Installation instructions on
page 12. If the pressure switch is one feet (.3M) below or above the pool
water level, reset the switch so that it is open when the pump is off and closed
when the pump is running. Turn the star -wheel on the switch clockwise ( )
to raise setting (heater below the pool) and counterclockwise ( ) to lower
the setting (heater above the pool – see Figure 29. T est the switch after resetting.
NOTICE: When the heater is mounted more than five feet (1.5M) above or
four feet (1.2M) below the deck level, a Pressure Switch is no longer adequate.
A Flow Switch must be installed instead.
NOTICE: Heater operation with incorrect
Pressure Switch setting may cause operation
Turn star wheel clockwise to raise
pressure set point if pressure switch is more
than 4 feet (1.2M) below water level
with no water flow. Operation of the heater
without sufficient water flow may severely
damage it.
Water
Pressure
Switch
Figure 28.
HIGH LIMITS
A “High Limit”, is a safety device that opens
the electrical circuit and shuts off the heater
based on a water temperature set point within
the “High Limit Device”. The MasterTemp
series of heaters contains two (2) high limit
devices which are located on the main inlet /
outlet header.
P/N 472592 Rev. C 10-5-07
A reference scale is on
the back of pressure switch
Turn star wheel counterclockwise to lower
pressure set point if pressure switch is more
than 5 feet (1.5M) above water level
Star Wheel
Figure 29.
Section 4. Operation
35
SAFETY CONTROLS, (cont’d.)
Flame Current
OPERATION OF IGNITION MODULE
The Ignition Module, (see Figure 30), is microprocessor based
and operates on 24VAC supplied by the transformer. The control
utilizes a microprocessor to continually and safely monitor, analyze,
and control the proper operation of the gas flame holder. The module
with the presence of the flame sensor, using flame rectification,
allows the heater to operate.
OPERATING THE CONTROL PANEL
The five operating switches are:
POOL ONPress this button to govern heater operation by the
pool temperature setting.
SPA ONPress this button to govern heater operation by the
spa temperature setting.
HEATER OFF Press this button to switch off the heater.
▲▲
▲ TEMPPress this button to raise the temperature setting.
▲▲
Check Point
Diagnostic LED
1 Flash- Air Flow Fault
2 Flashes - Flame No Call for Heat
3 Flashes - Ignition Lockout
Figure 30.
Temperature
Up and Down
Digital Temperature
Display
▼▼
▼ TEMPPress this button to lower the temperature setting.
▼▼
To toggle the display between degrees Centigrade (°C) and degrees
Fahrenheit (°F):
1. Turn the Operating Control OFF.
System Operation
Indicator Lights
Dual Temperature
Controls
Heater "OFF"
Switch
Figure 31.
2. Press ▲ TEMP or ▼ TEMP for 5 seconds. The display will flash once and change modes (°C to °F or vice versa).
3. Turn the Operating Control ON.
When either the ▲ TEMP or ▼ TEMP buttons are depressed, the digital display will indicate the temperature setting.
After five seconds, the display will return to the actual pool/spa temperature.
In addition to the digital temperature display , there are five indicator lights:
The POOL ON light indicates that the pool water temperature is governing operation of the heater.
The SPA ON light indicates that the spa water temperature is governing operation of the heater.
The HEATING light comes on and stays on when the burner is firing. This light should be on whenever the burner is on.
It blinks when the heater is calling for heat but not firing. If this light is on but the burner fails to come on, one of the
“service” lights should come on, indicating a fault in the system.
The SERVICE SYSTEM light indicates that there is insufficient water flow to the heater. If the pump is operating, this
usually indicates that the filter and/or skimmers should be cleaned (some filters may require back-washing). If the light
remains on after the filter/skimmers have been serviced, the system should be checked by a qualified service technician.
The SERVICE HEATER light indicates a fault in the heater or its controls. If this light comes on, shut down the heater
(See “TO TURN OFF GAS TO THE APPLIANCE” on
page 33), and have a qualified service technician check the
system.
Risk of explosion or fire causing burns or death if safety interlocks are disabled. DO NOT attempt to operate heater
when SERVICE HEATER light is on or if blower or burner will not start. Instead, follow instructions under “To Switch Off Gas to
the Appliance,” and call a qualified service technician to repair unit.
Rev. C 10-5-07 P/N 472592
WARNING
36
Door
Access
Panel
Top Panel
Door
Access Panel
Section 4. Operation
TEMPERATURE SETTING
The heater comes factory set at 78° F. for the pool mode and 100° F. for the spa mode. Using the up and down arrows,
you can set the thermostats to a minimum temperature of 65° F ., or a maximum of 104° F. If you desire to heat only one
body of water, the thermostat is capable of an of f mode. As an example, if you only wish to heat the spa and not the pool,
simply depress and hold the pool down arrow , and the thermostat will lower its setting to 65° F. then go to an off mode.
MAXIMUM TEMPERATURE SET POINT
1. Unbolt and remove the door panels (see Figure 32).
2. Access the control panel board on the underside of the top cover. Locate
the yellow button on the corner of the control board.
3. Push the Max. Temp. Set Point button on the back of the control
board (see
The following sequence should happen:
A.The unit will come on and the POOL ON light will come on.
B.Press the ▲ TEMP or ▼ TEMP pad (on TOP of the panel) to set
maximum pool temperature.
Figure 33).
C.Wait up to 30 seconds; the POOL ON light will go off and the
SPA ON light will come on. To override the time delay, push the
Max. Temp. Set Point button again.
D.Press the ▲ TEMP or ▼ TEMP button on the control panel
and set maximum spa temperature to 104°F (40°C) or less.
E.Wait up to 30 seconds; the SPA ON light will go off and
the unit will shut down. T o override the time delay, push
the Max. Temp. Set Point button again.
4. Reinstall the access door panels.
SE
MA
T
S
1
X
Figure 32.
SET
MA
S1
X
Figure 33.
P/N 472592 Rev. C 10-5-07
Section 5. Troubleshooting
Troubleshooting Instruction
Initial Troubleshooting
Only qualified, trained service technicians with appropriate test equipment should service the heater. Remember
that all parts of the system affect heater operation. Before starting this troubleshooting procedure, make sure that
the pump is running correctly, that there are no blockages in the system, that the valves are correctly set and that
the time clock is correctly set and is
NOTICE: Installing the black 120 volt plug in the control box and
then connecting the heater to a 240 volt line will destroy the trans -
former, control broad, and ignition control module, and will void the
warranty. If you install the red 240 volt plug and then connect the
heater to a 120 volt line, the heater will not operate.
READ THE FOLLOWINGCAREFULLY:
1. Check the line voltage to your heater. This heater will operate
Start here for directions to specific Troubleshooting Chart
running.
IMPORTANT! READ ME FIRST!
on either 120 Volts AC or 240 Volts AC.
2. Remove the covers and check the 12-pin plug in the back of the
control box. The plug must match the voltage in the heater circuit.
3. If the 12-pin plug is not plugged into the back of the control
box, select the correct plug from the bag in the control box
and plug it in. The
is for 240 volts.
BLACK
plug is for 120 volts, the RED plug
37
Is green “POOL” or “SPA”
LED “on”
Is red “SERVICE SYSTEM”
LED “on”
Is red “SERVICE HEATER”
LED “on”
Turn off power to heater for
about 5 seconds, and turn
back on. Make sure temperature setting is above water
temperature. Wait one minute.
Do any diagnostic LED’s on
back of board (AGS, AFS,
SFS, HLS, PS, or
THERMISTOR) come “on”
and stay on?
NOTICE: Any or all of the diagnostic LED’s may come “on”
momentarily when you turn on
the power to the heater.
?
YES
?
NO
?
NO
YE
YES
NO
Are any red diagnostic LED’s on back of
S
board (AGS, AFS,
SFS, HLS, PS or
THERMISTOR)
Does red “SERVICE
HEATER” LED come
“on”
NO
YES
NO
NO
“on”
YES
YE
Go to chart “HEATER WILL
NOT FIRE - A”
(Page 38)
Go to chart “HEATER WILL
NOT FIRE - B”
(Page 39)
Go to specific safety switch
troubleshooting chart
(Pages 41 and
S
Go to chart ‘HEATER WILL
NOT FIRE -C”
(Page 40)
42)
WARNINGWARNING
Disconnect power before servicing any components.
Rev. C 10-5-07 P/N 472592
Hazardous voltage. Can shock, burn or kill.
Verify that water temperature setting is
above water temperature reading. If it is,
and heater either will not fire or no red
LED’s come “on”, replace Control
switch terminals to remedy a failed safety switch.
Board.
Fire and Explosion hazard.
Do not jumper
38
Heater Will Not Fire - A
Start
Section 5. Troubleshooting
Is green “SPA” or
“POOL” LED
YES
Check that correct 12-pin
plug is installed (red is
240V, black is
If plug is not installed:
Install correct plug.
240V plug in 120V
circuit: Replace with
correct plug.
120V plug in 240V
circuit: Replace trans-
former, control board,
and ignition control
module (see “HEATER
WILL NOT FIRE-C and
-D”, Pages 40 and 41).
Check fuse and all
other 24V components
damage.
for
“on”
120V)
NO
NO
YES
Depress “POOL” or “SPA” ON
button on Membrane Pad.
Does “POOL” or “SPA” LED
on?
come
YES
YES
Check for line voltage to
heater
.
Check for 24 VAC at secondary of Transformer
Check for Line Voltage
between L1 and L2 terminals
on Terminal
Check for Line Voltage at
Transformer primary pins.
White connects to Pin 3 on
Transformer, Black to Pin 2,
Orange to Pin 1.
240V: check Pin1 to Pin 3.
120V: check Pin 2 to Pin 3.
Board.
YES
NO
NO
YES
NO
.
NO
NO
YES
Heater should fire on demand
heat.
for
Restore power to heater.
Check wiring connections
between power supply and
Junction Box and between
Junction Box and Terminal
Board; restore continuity
Check wiring connections
between Terminal Board and
Transformer primary and
restore continuity
Replace Transformer.
.
.
S
YE
NO
GO TO
“HEATER WILL NOT FIRE - B”
Page 39
Jumper Fireman’s Switch at
Terminal Board and depress
“POOL” or “SPA” ON button on
membrane pad. Does “SPA” or
“POOL” LED come
Leaving jumper in place,
check for 24 VAC between
Fireman’s Switch terminals
and
ground.
Remove jumper. Check ribbon
cable connection between
Membrane Pad and J6 on
Control Board. Depress
“POOL” or “SPA” On pad
again. Does “POOL” or “SPA”
LED come
Jumper pins 6 and 5 on J6 of
Control Board. Does “SPA”
LED come on?
Jumper pins 6 and 4 on J6 of
Control Board. Does “POOL”
LED come
Remove jumper. Check wiring
between Transformer and J7
terminals on Control Board
and between J7 and
Fireman’s Switch on Terminal
Board, check fuse, and
restore continuity
Heater should fire on
demand for
Replace Membrane Pad.
Replace Control Board.
relay).
.
heat.
P/N 472592 Rev. C 10-5-07
Section 5. Troubleshooting
Heater Will Not Fire - B
Start
39
Is red “SERVICE
HEATER” LED “on”
YES
NO
CONTINUE
Is red “SERVICE SYSTEM”
LED on?
YES
Verify that pump is on, filter is
not blocked, and the water
flow is above the minimum
requirement.
YES
With pump running, adjust
Water Pressure Switch to
lower pressure until ‘SERVICE SYSTEM” LED goes
out. Then verify that “SERVICE SYSTEM” LED goes on
with pump off.
NO
Check that water pressure is
within the adjustment range of
the Pressure Switch (0-5 psig)
YES
Verify that switch wiring is OK
and Pressure Switch port is
not blocked, and replace
water Pressure Switch.
NO
NO
NO
YE
Increase POOL/SPA temperature setting on Membrane
Pad above actual water temperature. Heater should fire
on demand for heat. If not,
and no other red LED’s light,
replace Control
Board.
Service pump/filter and eliminate other flow
S
Heater should fire on call for
obstructions.
heat. Re-verify that water flow
is above minimum requirement.
If water pressure is outside of
adjustment range that will
open switch with pump off
and close switch with pump
on, replace with flow switch
set above minimum flow
requirement
Minimum Flow Requirements
.
Rev. C 10-5-07 P/N 472592
Check whether any of the
red diagnostic LED’s on back
of board (AGS, AFS, SFS,
HLS or PS) are
If any red diagnostic LED’s
(AGS, AFS, SFS, HLS, PS, or
THERMISTOR) come “on”, go
to to Pages 42 and
Did burner fire at all?
Go to “BURNER
TROUBLESHOOTING”
44)
(Page
Go to “HEATER WILL NOT
FIRE-D” (Page
Replace Ignition Control
Module.
Check for 24 VAC between
VAL and GND terminals on
Ignition Control Module.
SEE NOTE
Check for 24 VAC between
VAL and GND terminals on
Control Board. SEE NOTE
Fix wiring between VAL and
GND terminals of Ignition
Control Module and Control
Board.
2.
43.
CONTINUE
YES
41)
NO
YES
2.
NO
YES
NO
NO
YE
S
YE
NO
Turn off power to
heater for 5 seconds,
and turn back on.
Make sure temperature setting is above
water temperature.
Wait one minute.
Does heater fire and
on?
stay
Did Blower come on?
Verify that gas is flowing to burner during
ignition try. Observe
gas meter for movement during ignition
try (wait for about 30
seconds after calling
heat).
for
Check for 24 VAC
between TH and GND
S
terminals on Ignition
Control Module.
SEE NOTE
Check for 24 VAC
between TH and GND
terminals on Control
Board. SEE NOTE
Check for 24 VAC
between GAS terminals on Control
Board. SEE NOTE
Replace Control
Board.
1.
YE
NO
NO
Go to “INITIAL
TROUBLESHOOTING”
Continue to observe heater
for several minutes. Cycle
heater on and off several
times. Observe for delayed or
YE
S
NO
S
NO
S
YE
NO
1.
S
YE
2.
rough ignition, poor combustion, premature extinction of
flame, evidence of boiling, or
operation of any diagnostic
LED. Go to pertinent troubleshooting section if any
malfunction is
Replace Control Board.
Verify that gas supply is open
all the way to Gas Valve, and
Gas Valve is set at “on”
position.
Check for 24 VAC to Gas
NO
Valve terminals during ignition
try. (Voltage appears about 24
seconds after call for heat).
SEE NOTE
Replace Gas Valve with
identical p
Fix wiring between TH and
GND terminals of Ignition
Control Module and Control
Board.
Replace Control Board.
Fix wiring between GAS terminals on Control Board and
Gas Va
NOTE 1: Voltage appears immediately after call for heat, and may be
on for only about 30 seconds.
NOTE 2: Voltage appears about 24
seconds after call for heat, and may
be on for only about 7 seconds.
lve.
observed.
2.
YES
art.
P/N 472592 Rev. C 10-5-07
Section 5. Troubleshooting
Heater Will Not Fire - D
IMPORTANT! READ ME FIRST!
IMPORTANT! READ ME FIRST!!
If your heater is correctly connected to 240 Volts AC, the
Ignition Control Module (ICM) will convert the 240VAC to
an intermittent pulse to the ignitor. Digital meters don’t read
this type of signal well. (An analog meter will give a better
reading than a digita
l meter). If the ICM is bad, your volt-
Start
41
meter will read either 0 VAC or 240 VAC. If your ICM is
good, your meter will read some voltage between 0 and
240 VAC. Exactly what reading you get will depend on the
meter, but with a good ICM, the reading won’t be 0 VAC or
240 VAC, but somewhere in
between.
Gas flows during ignition try, but burner
does not fire.
YE
S
Check voltage across
igniter leads;
Replace Ignition
Control Module. On a
120 V installation,
check the ignitor for
damage if it has seen
AC.
240 V
OK?
NO
NO
YES
Go back to chart “HEATER WILL
NOT FIRE-C” (Page 40).
Check gas pressure. OK?.
NO
Increase gas flow into heater:
• Replace gas line with larger
line;
• Replace regulator;
• Replace meter; or
• All of the
above.
YES
Replace HSI Igniter.
Rev. C 10-5-07 P/N 472592
42
Section 5. Troubleshooting
Diagnostic LED's: AGS, AFS, HLS, PS, THERMISTOR
AGS or HLS "on"
Replace High Limit
Switch (HLS) or
Automatic Gas
Shutoff
If problem persists, verify proper operation of Internal Bypass Valve
and Thermal Governor, and check for Heat Exchanger
(AGS)
CONTINUE
YES
PS "on"
Verify that wiring is
OK and pressure tap
is not blocked. Replace Pressure
Switch
CONTINUE
AFS "on"
Replace Blower.
Verify that wires BM
and F1 are correctly
connected at the
terminal strip (see
Heater Connection
Diagram, Page 30)
YES
.
YE
YE
NO
Verify that water flow rate is
above minimum required for
heater
.
S
YE
Verify that inlet water temperature is below 104˚
Verify that water flow rate is
above minimum required for
heater
.
Adjust Water Pressure Switch to close with pump running and open with
pump of
Does Blower operate?
Disconnect Blower and check
S
for line voltage between pins
1 and 3 of Blower Connector
on ignition try
Check for 24 VAC between
S
24 VAC and GND terminals
on Ignition Control Module on
ignition try. Check that IND
wire is correctly
Verify correct
connection of wiring between
24 VAC and IND terminals on
Ignition Control Module and
Control Board, and replace
Control
f.
Board.
F.
blockage.
YES
NO
.
NO
connected.
NO
NO
NO
NO
YE
Service pump and filter to
restore proper flow. After servicing, verify proper operation
of Pressure Switch
Replace thermistor or Control
Board to correct
Service pump and filter to
restore proper flo
S
Verify that there is no blockage in Blower intake, Heat
Exchanger, and exhaust and
that exhaust is not too long
(see “Indoor Vent Installation”,
Page 23.
Verify correct connection of
wiring and that pressure taps
to AFS are OK.
Verify that vinyl tubing to AFS
and Blower is not misrouted,
kinked, disconnected, or
punctured.
Replace Air Flow Switch
(AFS).
If problem persists, replace
.
Blower
(PS).
overheating.
w.
CONTINUE
Disconnect wires F1
and F2 from Ignition
Control Module and
short them together.
Does Blower come
on?
S
YE
NO
NO
NO
THERMISTOR "on"
CAUTION
remedy a failed switch.
P/N 472592 Rev. C 10-5-07
Do not jumper a safety switch to
Connect correctly and retry.
Does Blower st
Replace Blower. Does Blower
start on ignition
Replace Ignition Control
Module.
Verify Thermistor wiring. If
OK, replace Thermistor
art?
try?
.
NOTE: ES1 is a spare and should be jumpered.
Section 5. Troubleshooting
Diagnostic LED's: SFS
SFS "on"
Heater starts and runs OK,
but temperature of exhaust
climbs to 450˚–500˚ in 3–5
minutes.
Heater starts after several
tries, exhaust temperature
stays below 250˚.
OR
Heater doesn’t start at all
(exhaust stays cold).
Check pressure and volume
of fuel
supply
Disconnect the sensor and
check continuity across its
terminals. Resistance
should be 3.5-4.0 megaohms.
= open circuit;
0 = shorted.
Does sensor check
YES
Check continuity in wiring
harness between Control
Board and Probe.
YES
Continuity
Check the J3 and J6
connectors for corrosion/
looseness on the male
pins.
Clean/tighten pins as
needed.
Reset power to Heater
and retry. Heater should
fire.
OK?
NO
YE
NO
OK
OK?
S
DONE
YES
YES
NO
Check Heat Exchanger
Coil for leaks, liming, soot,
correctly?
NO
DONE
NO
YE
w.
S
or low flo
Check Thermal
Regulator: Open at
120˚?
Correct problem;
Heater should fire
Check Thermal-Regulator:
Seats
NOT OK
Correct Fuel Supply, reset
Heater and retry. Heater
should fire correctly
NO
Replace Stack Flue Sensor
Reset power to Heater and
retry. Heater should
Repeat checks on fuel
supply, Thermal Regulator,
check for correct orifices,
etc.
Does the Digital
Temperature Display show
Error Code “E05” or “E06”
NO
YES
NO
NO
43
NO
YES
.
.
fire.
?
NO
(HD )
NO
(Basic)
Replace Heater
Membrane
Replace Heater
Control
Reset power to Heater and
retry. Heater should
Check Heat Exchanger Coil for
leaks, liming, soot, or low flow
Replace Heater Control Board.
Reset power to Heater and
retry. Heater should
Replace Heater Membrane Pad.
Reset power to Heater and
retry. Heater should
Pad.
DONE
Board.
DONE
fire.
NO
DONE
fire.
NO
DONE
fire.
.
Rev. C 10-5-07 P/N 472592
44
Section 5. Troubleshooting
Burner Troubleshooting
SYMPTOMCAUSEREMEDY
Loud, high-pitched whineFlame is too rich.Verify pressure tap between gas valve
and blower inlet.
See page 15 and verify t hat the gas
regulator setting is
Contact a qualified technician or service
agency to replace the gas orifice.
Flame is “fluttery.”Flame is too lean.See page 15 and verify t hat the gas
Exhaust may have acridregulator setting is –0.2" (–0.5cm) wc.
smell or burner may f
to stay lit.
Burner pulsates orExhaust vent is too long.Reduce length of exhaust vent and/or
surges, especially on
ignition.
Combustion appearsFlame current is notCheck for wet or damaged igniter with
normal, but flame doesbeing sensed.
not stay lit.
ail
Contact a qualified technician or service
agency to replace the gas orifice.
number of
low resistance to ground. Replacewith
new igniter.
Verify burner flameholder is properly
grounded.
Replace
elbows.
Ignition Control Module.
–0.2" (–0.5cm) wc.
Heat Exchanger Troubleshooting
SYMPTOMCAUSEREMEDY
Boiling in heat exchanger.Low water flow to heater.pump and or filter.
May be accompanied by
Drill thru the NPT Port, then
use a 3/4" Brass Nipple and
Elbow (user supplied) for a
PRV Installation.
45
Maintenance Instructions
CARE AND MAINTENANCE
WARNING
Risk of fire or explosion from flammable vapors. Do not store gasoline, cleaning fluids, varnishes, paints, or other volatile
flammable liquids near heater or in the same room with heater.
The following maintenance is recommended every six months and at the start of every swimming season:
1. Inspect the heater panels and venting system to make sure that there are no obstructions to the flow of ventilating air
or burner exhaust. Check that room air intakes are open and clear of obstructions.
2. Keep the area in and around the heater clear and free from combustible materials, gasoline and other flammable
vapors and corrosive liquids.
3. T est the operation of the pressure relief valve by lifting the valve lever.
4. Test for proper operation of the pressure switch. (See “WATER PRESSURE SWITCH” for testing instructions).
5. On enclosed installations with high-temperature Special Gas Vent systems, repeat the “Final Installation Check,”
page 27. Check for evidence of joint leakage. Make sure that joints have not slipped partially or completely apart.
Check pipe and fittings for cracks or breaks. The combustion air blower is permanently lubricated, and does not
require periodic lubrication. The burner does not require maintenance or adjustment by the user. Call a qualified
service technician if you suspect that the burner may require maintenance.
PRESSURE RELIEF VALVE
Canadian code requires and some U.S. local codes may require installation of a
pressure relief valve (PRV). Purchase separately and install a 3/4" pressure
relief valve complying with the ANSI/ASME Boiler and Pressure Vessel Code,
having a capacity equal to the Btu/hr rating of the heater. The relief pressure of
the valve MUST NOT EXCEED 50 PSI.
The relief valve must be installed vertically. To install the valve, use a 3/4" x 2”
brass nipple at the manifold, the two brass elbows and nipples are (user supplied),
as illustrated in
adapter and the relief valve.
To avoid water damage or scalding from operation of the relief valve, install a
drain pipe in the outlet of the pressure relief valve that will direct water discharging
from the valve to a safe place for disposal. Do not install any reducing couplings
or valves in the drain pipe. The drain pipe must be installed so as to allow complete
drainage from the valve and drain line. The relief valve should be tested at
least once a year by lifting the valve lever.
Figure 34. No valve is allowed to be placed between the manifold
WARNING
Figure 34.
Explosion hazard. Any heater installed with restrictive devices in the piping system downstream from the heater, (including
check valves, isolation valves, flow nozzles, or therapeutic pool valving), must have a relief valve installed as described above.
Rev. C 10-5-07 P/N 472592
46
Section 6. Maintenance
AFTER START-UP
CHECKING WATER FLOW
WARNING
Fire or flooding hazard. If the unit overheats and the burner fails to shut off, follow instructions under “To Turn Off Gas to the
Appliance”, page 33, and call a qualified service technician to repair unit.
After start-up, the outlet water pipe should feel slightly warmer than the inlet pipe. If it feels hot, or if you hear the water in the heater
boiling, there may not be enough water flow to the appliance. Make sure that the filter is not plugged. If water temperature remains high
but the unit continues to operate, turn off the appliance and call your service technician.
SPRING AND FALL OPERATION
If the pool is only used occasionally, lower the pool thermostat to 68° F (20° C) and leave the heater on. This will keep the pool and the
surrounding ground warm enough so that the heater should restore the pool to a comfortable temperature within about one day.
WINTER OPERATION
CAUTION
• Operating this heater continuously at water temperatures below 68° F. (20° C) will cause harmful condensation and will damage
the heater and void the warranty.
• If the heater has been drained for freezing condition, do NOT turn "ON" until the system is circulating water.
• Water trapped in the heat exchanger can result in freeze damage to the exchanger or headers. Freeze damage is specifically not
covered by the warranty.
• When starting the heater for the swimming season with a water temperature below 50° F (10° C), the heater may be used to heat
the water; however, make sure that the heater operates continuously until the water temperature reaches the heater’s minimum
setting of 68° F (20° C). During cold weather, if there is no danger of freezing, operate the filter pump continuously even if the
heater is not operating. If air temperatures are expected to drop below freezing (32° F/0° C), shut down the heater and winterize
it.
For outdoor heaters in freezing climates, shut the heater down and drain it for winter as follows:
1 .Turn off electrical supply to the heater and pump.
2 .Close main gas control valve and manual gas valve (located outside the heater). T urn switch on heater gas valve to OFF.
3 .In northern climates where they may be required, open drain cock located on the bottom of the manifold adapter, and drain the heat
exchanger and manifold adapter completely. If heater is below pool water level, be sure to close isolation valves to prevent dr aining
the pool (isolation valves are not required and should not be used on heaters installed above pool water level except when needed
for winterizing valves). Assist the draining by blowing out the heat exchanger through the pressure switch fitting with low pressure
compressed air (less than 5 PSI or 35 kPa).
WARNING
Explosion hazard. Purging the system with compressed air can cause components to explode, with risk of severe injury or
death to anyone nearby. Use only a low pressure (below 5 PSI or 35 kPa), high volume blower when air purging the heater,
pump, filter, or piping.
4 .Remove the Water Pressure Switch. Plug the port in the manifold to prevent bugs and dirt from getting into the manifold.
5 .Drain the plastic inlet/outlet manifold through the outlet pipe. If the pipe does not drain naturally to the pool, install a drain cock
in the outlet pipe to drain the manifold.
6 .Cover air inlet grate with a plastic bag to prevent bugs, leaves, etc., from getting into the heater .
NOTICE: Water trapped in the heater can cause freeze damage. Allowing the heater to freeze voids the warranty.
To return the heater to service after winterizing:
1 .Close drain cock and fittings.
2.Before starting the heater, circulate water through the heater for several minutes until all air noises stop. See also “BEFORE
ST AR T -UP” (page 32) and “CARE AND MAINTENANCE” (page 45).
(See additional notes under Important Notices in Introduction.)
P/N 472592 Rev. C 10-5-07
Section 6. Maintenance
47
MAINTAINING POOL TEMPERATURE
T o maintain pool temperature, make sure that the heater switch and valving are reset to pool settings after using the spa.
ENERGY SAVING TIPS
1. Keep the pool or spa covered when not in use. This will reduce heating costs, reduce water evaporation, conserve
chemicals and reduce load on the filtering system.
2. Reduce pool thermostat to 78° F (25° C) or lower; reduce spa temperature to 100° F (38° C). This is accepted as
being the most healthy temperature for swimming by the American Red Cross.
3. Use a time clock to start the filter pump at 6 a.m. or later. The swimming pool loses less heat after daybreak.
4. For pools used only on weekends, lower the thermostat setting by 10° F to 15° F (5° C to 8° C) during the week to
reduce heat loss. A properly sized heater will restore normal temperature within one day.
5. Turn the heater off when the pool will not be used for an extended period.
6. Follow a regular program of preventive maintenance for the heater each new swimming season. Check operation of
the heater and its controls.
CHEMICAL BALANCE
POOL AND SPA WATER
Your Pentair pool heater was designed specifically for your spa or pool and will give you many years of trouble-free
service, provided you keep your water chemistry in proper condition.
W ater chemistry should follow good swimming pool water chemistry practices. When using a chlorinator , install it down
stream from the heater and at a lower level than the heater outlet. Install a corrosion resistant positive seal “Check
Valve”, (P/N R172288), between the heater and the chlorinator to prevent concentrated chemicals from back-siphoning
into the heater. Back-siphoning is most likely to occur when the pump stops, creating a pressure-suction dif ferential. Do
NOT sanitize the pool by putting chlorine tablets or sticks into the skimmer(s). When the pump is off, this will cause a high
concentration of chlorine to enter the heater, which could cause corrosion damage to the heat exchanger.
Three major items that can cause problems with your pool heater are: improper pH, disinfectant residual, and total
alkalinity. These items, if not kept properly balanced, can shorten the life of the heater and cause permanent damage.
CAUTION
Heat exchanger damage resulting from chemical imbalance is not covered by the warranty.
WHAT A DISINFECTANT DOES
T wo pool guests you do not want are algae and bacteria. To get rid of them and make pool water sanitary for swimming
- as well as to improve the water's taste, odor and clarity - some sort of disinfectant must be used.
Chlorine and bromine are universally approved by health authorities and are accepted disinfecting agents for bacteria
control.
WHAT IS A DISINFECTANT RESIDUAL?
When you add chlorine or bromine to the pool water, a portion of the disinfectant will be consumed in the process of
destroying bacteria, algae and other oxidizable materials. The disinfectant remaining is called chlorine residual or bromine
residual. You can determine the disinfectant residual of your pool water with a reliable test kit, available from your local
pool supply store.
Y ou must maintain a disinfectant residual level adequate enough to assure a continuous kill of bacteria or virus introduced
into pool water by swimmers, through the air, from dust, rain or other sources.
Rev. C 10-5-07 P/N 472592
48
Section 6. Maintenance
CHEMICAL BALANCE, (cont’d.)
It is wise to test pool water regularly. Never allow chlorine residual to drop below 0.6 ppm (parts per million). The
minimum level for effective chlorine or bromine residual is 1.4 ppm.
pH - The term pH refers to the acid/alkaline balance of water expressed on a numerical scale from 0 to 14. A test kit for measuring pH
balance of your pool water is available from your local pool supply store; see T able 12.
Muriatic Acid has a pH of about 0. Pure water is 7 (neutral). Weak L ye solution have a pH of 13-14.
RULE: 7.4 to 7.6 is a desirable pH range. It is essential to maintain correct pH, see Table 12.
If pH becomes too high (over alkaline), it has these effects:
1 .Greatly lowers the ability of chlorine to destroy bacteria and algae.
2.Water becomes cloudy.
3 .There is more danger of scale formation on the plaster or in the heat exchanger tubing.
4 .Filter elements may become blocked.
If pH is too low (over acid) the following conditions may occur:
1 .Excessive eye burn or skin irritation.
2 .Etching of the plaster .
3 .Corrosion of metal fixtures in the filtration and recirculation system, which may create brown, blue, green, or sometimes almost
black stains on the plaster.
4 .Corrosion of copper tubes in the heater , which may cause leaks.
5 .If you have a sand and gravel filter, the alum used as a filter aid may dissolve and pass through the filter.
CAUTION: Do not test for pH when the chlorine residual is 3.0 ppm or higher, or bromine residual is
6.0 ppm or higher. See your local pool supply store for help in properly balancing your water chemistry.
RULE: Chemicals that are acid lower pH. Chemicals that are alkaline raise pH.
ALKALINITY High or Low:
"T otal alkalinity" is a measurement of the total amount of alkaline chemicals in the water, and control pH to a great degree. (It is not the
same as pH which refers merely to the relative alkalinity/acidity balance.) Your pool water's total alkalinity should be 100 - 140 ppm to
permit easier pH control.
A total alkalinity test is simple to perform with a reliable test kit. Y ou will need to test about once a week and make proper adjustments
until alkalinity is in the proper range. Then, test only once every month or so to be sure it is being maintained. See your local pool dealer
for help in properly balancing the water chemistry.
WATER CHEMISTRY PARAMETERS
Disinfectant levelsMinimumIdealMaximum
Free Chlorine, ppm1.02.0-4.010.0
Combined Chlorine, ppmNoneNone 0.2
Bromine, ppm2.04-610.0
Other SanitizersLevels not established. Consult local health department before use.
Chemical Values
pH7.27.4-7.67.8
Total Alkalinity (Buffering), ppm6080-100180
as CaCO3
Total Dissolved Solids, ppmN/A N/A1,500 ppm > TDS at startup*
Calcium Hardness, ppm, as CaCO3150200-400500-1,000
Heavy MetalsNoneNoneNone
Biological Values
AlgaeNoneNoneNone
BacteriaNoneNoneRefer to Local Cod
Table 12.
e
NOTICE:
*Start-up TDS includes source water TDS and any other inorganic salt added at start-up.
P/N 472592 Rev. C 10-5-07
Failure to adhere to the listed water chemistry parameters may result in premature failure of the heat exchanger and will void the warranty.
For complete
Electrical System
parts breakdown
(Key Nos. 1 through 4),
See Page 53
3
MASTERTEMP REPLACEMENT PARTS
1
For complete
Burner System
2
5
parts breakdown
(Key Nos. 5 through 7),
See Page 51
49
For complete
Water System
parts breakdown
(Key Nos. 8 through 9),
see Page 52
7
6
9
4
8
Repair Parts are available from your Pentair dealer.
If your dealer cannot supply you, call Customer Support at 1-800-831-7133.
Rev. C 10-5-07 P/N 472592
50
For Heater mounting
bolts and clamps,
purchase separately
Bolt Down Bracket Kit,
Part No.
460738.
MASTERTEMP REPLACEMENT PARTS
22
1
27
Lead
Anchor
26
20
21
18
19
2
3
4
8
9
10
11
12
13
17
16
2
7
6
5
23
28
P/N 472592 Rev. C 10-5-07
15
14
24
23
25
51
MASTERTEMP REPLACEMENT PARTS
REPAIR PARTS – BURNER SYSTEM
Model
Key Part200NA250NA300NA
No. Description
1Combination Gas Control Valve Kit42001-0051S42001-0051S42001-0051S42001-0051S
23/4" Union
3Gas Orifice
4Gas Orifice O-Ring
•Gas Orifice Kit – NG (Incl. Key Nos. 3 and 4)†77707-043146073946075377707-0411