EVERPURE® H-300
H-300 DRINKING WATER SYSTEM
The same commercial quality that makes Pentair® Everpure® the overwhelming
choice for water filtration in restaurants is also available for your home. The
Pentair Everpure exclusive precoat filtration technology combines Micro-Pure
and a unique pleated filter membrane. This highly engineered design offers a
large filtering surface area, longer filter life, and consistent performance.
FE ATURES
Commercial Grade Filtration
• Exclusive Micro-Pure filter material
reduces contaminants commonly
found in tap water
• Commercial grade metal canister
protects the filter system from
splitting or bursting
22”
Great Tasting Water
• Retains vital minerals found naturally
in water to ensure the clean, crisp
taste of your water
• Absorbs common earthy, moldy, fishy
tastes, and odors
5”
®
Added Benefits
• Built-in water shut-off allows for
easier cartridge changes
• Helps prevent lime and scale build-up
in water appliances
SPECIFICATIONS
• Flow rate
controlled at 0.5 gpm (1.9 Lpm)
• Temperature
35-100° F (2-38° C)
cold water use only
• Pressure
10-125 psi (0.7-8.6 bar)
non-shock
• Capacity
300 gal. (1,135 L)
• Required Space
5W x 22H x 5D in
13W x 56H x 13D cm
FILTRATION & PROCESS EVERPURE H-300 DRINKING WATER SYSTEM
SUBSTANCE REDUCTION
• Lead
• NSF/ANSI Standard 53 certified to
reduce cysts such as Cryptosporidium
and Giardia by mechanical means
• Volatile Organic Chemicals (VOCs),
including THMs
• Chlorine taste & odor
• Dirt and cloudiness*
• Mold and algae*
• Reduces particles as small as 0.5
micron in size by mechanical means
• Enhanced with KDF media to inhibit
scale build-up that can damage
equipment
*As tested by Everpure, LLC.
EPA EST. NO. 002623-IL-002
ORDERING INFORMATION
MODEL PART NO DESCRIPTION
H-300 EV927076 Drinking water system
H-300 EV927072 Cartridge
GENERAL INSTALLATION / OPERATION / MAINTENANCE REQUIREMENTS
This drinking water system must
be maintained according to the
manufacturer’s instructions, including
replacement of filter cartridges. The
substances reduced or removed by this
system are not necessarily in your water.
Read the performance data sheet.
It is recommended that before
purchasing a water treatment unit, you
have your water tested to determine
your actual treatment needs.
Health Claim Performance Certified by NSF*
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in
water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system,as specified in NSF/ANSI 42 and 53.
SUBSTANCE
INFLUENT CHALLENGE
CONCENTRATION
Space required: 5W x 22H x 5D in
(13W x 56H x 13D cm) including
2-1/2 inches of clear space under unit
for cartridge change.
Do not use with water that is
microbiologically unsafe or of unknown
quality without adequate disinfection
before or after the system. Systems
certified for cyst reduction may be used
on disinfected water that may contain
filterable cysts.
MAX. PERMISSIBLE PRODUCT
WATER CONCENTRATION
A separate drinking water faucet is
required.
Install vertically with cartridge hanging
down.
Replace cartridge when capacity is
reached, or when flow becomes too
slow. To ensure optimum water filtration, cartridges should be changed
annually.
REDUCTION
REQUIREMENTS
MINIMUM
REDUCTION
AVERAGE
REDUCTION
Standard 42 – Aesthetic Effects
Chlorine 2.0 mg ± 10% – ≥ 50% – 96.8%
Particulate, Class I
Particles 0.5 - <1 μm at least 10,000 particles/mL – ≥ 85% 99.2%
Standard 53 – Health Effects
Cyst Minimum 50,000/L – 99.95% 99.99% 99.99%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L – 99.4% 98.8%
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L – 97.3% 98.7%
Chloroform 0.310 mg/L 0.015 mg/L – 95.7% 98.6%
(VOC surrogate chemical)
*Tested using flow rate = 0.5gpm; pressure = 6 0 psig; pH = 7.5 ±0.5; temp. = 20° C ±2.5º C
®
Everpure
California Department of Public Health Certificate Number: 11-2104
Warranty – Everpure Drinking Water Systems are warranted to be free of defects for a full twelve (12) months after purchase. A detailed warranty statement is
provided with each system.
, Micro-Pure® and the silver canister color are registered trademarks of Pentair Filtration Solutions, LLC ©2013.
System Tested and Certified by NSF International against NSF/
ANSI Standard 42 and 53 for the reduction of:
Standard No. 42 Aesthetic
Effect:
Chemical Reduction
• Taste and Odor
• Chlorine Taste & Odor
Mechanical Filtration
• Particulate Reduction: Class I
FILTRATION & PROCESS
5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209
P: 262.238.4400 | F: 262.238.4404 | WWW.PENTAIRAQUA.COM | WWW.RESIDENTIAL.EVERPURE.COM | CUSTOMER CARE: 800.279.9404
All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. All other registered and unregistered trademarks and logos are the property of their
respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
Pentair is an equal opportunity employer.
310920 REV F JL14 © 2014 Pentair Residential Filtration, LLC. All Rights Reserved.
Standard No. 53 Health Effects:
Chemical Reduction
• VOC
• Lead
Mechanical Filtration
• Cyst