Pentair Everpure DEV3115-69 Specifications

ROmate™ Storage Tanks
A family of hydro-pneumatic Storage Tanks for storing and dispensing Reverse Osmosis (RO)/High Purity water
DEV311569 ROmate 15
DEV311570 ROmate 20
DEV311571 ROmate 30
DEV311572 ROmate 40
DEV311573 ROmate 80
BENEFITS
100% seamless composite construction
Produced using NSF and/or FDA listed materials
Meets stringent US requirements for water components
Environmentally safe, 100% lead-free
Will not introduce chemicals or elements into water
Pre-installed inlet-outlet assembly, reduces installation time and cost
Factory-backed 5-year warranty
INSTALLATION TIPS OPERATION TIPS APPLICATION/SIZING
To insure adequate ow and pressure to the water
using equipment, do not reduce piping/tubing size between storage tank and distribution plumbing
Piping/tubing size from the RO unit to the storage tank can be smaller than the distribution piping/tubing from the storage tank to the water using equipment
The product water tubing/piping and associated
ttings connecting the RO product outlet to the
storage tank and equipment being serviced should be suitable for use with high purity water
Select a location capable of supporting the normal operating weight of the tank with a safety factor of at least 1.5. This will insure adequate tank support in the unlikely event pre-charge pressure is lost
Drain tank and check storage tank pre-charge pressure on an annual basis. As pre-charge pressure varies, so does stored water volume and useable pressure
Lower pre-charge pressures allow the storage tank to accept more water, but pressure drops rapidly as water is drawn
Higher pre-charge pressures allow the storage tank to accept less water, but pressure drops slowly as water is drawn
Rapid on-off cycling of RO system may indicate
insufcient pre-charge pressure
Sanitize storage tank on an annual basis
For storing and dispensing RO/High Purity water in foodservice applications
Usable capacity will vary based on tank size, pre-charge pressure and RO system on-off pressure setting. The data shown below is one capacity example based on a 28 psi (1.9 bar) pre-charge
Usable Storage Between
Model
ROmate 15 4.3 Gallons (16.2 liters)
ROmate 20 5.8 Gallons (22.1 liters)
ROmate 30 8.7 Gallons (33.0 liters)
ROmate 40 11.9 Gallons (45.0 liters
ROmate 80 25.6 Gallons (96.9 liters)
Contact EVERPURE Technical Service department for additional application assistance
30/50 psi (2.1/3.4 bar)
SPECIFICATIONS
H
W, D
Overall Dimensions:
H W, D
ROmate 15
ROmate 20
ROmate 30
ROmate 40
ROmate 80
26.5"
(670mm)
32.25"
(820mm)
44"
(1120mm)
56.75"
(1440mm)
55.5"
(1410mm)
Inlet–Outlet connection: ROmate 15 1" male NPT ROmate 20 1" male NPT ROmate 30 1" male NPT ROmate 40 1" male NPT ROmate 80 11⁄4" male NPT
16"
(410mm)
16"
(410mm)
16"
(410mm)
16"
(410mm)
24.25"
(620mm)
ROmate™ Storage Tanks
Pressure Requirements: Maximum Operating: 125 psi (8.62 bar), non-shock Pre-Charge: 5-50 psi (0.35-3.45 bar) typical
Maximum Operating Temperature: 125°F (49°C)
Shipping Weight: ROmate 15 15 lbs. (6.8 Kg) ROmate 20 19 lbs. (8.6 Kg) ROmate 30 23 lbs. (10.5 Kg) ROmate 40 30 lbs. (13.6 Kg) ROmate 80 58 lbs. (26.4 Kg)
Approximate Operating Weight @ 50 psi (3.45 bar) with 5 psi (0.35 bar) pre-charge: ROmate 15 99.2 lbs. (45.0 Kg) ROmate 20 134.0 lbs. (60.8 Kg) ROmate 30 194.3 lbs. (88.1 Kg) ROmate 40 264.0 lbs. (119.8 Kg) ROmate 80 561.5 lbs. (254.7 Kg)
WARRANTY
Everpure water treatment systems (excluding replaceable elements) are covered by a limited warranty against defects in material and workmanship for a period of five years after date of purchase
Everpure replaceable elements (filter cartridges and water treatment cartridges) are covered by a limited warranty against defects in mate­rial and workmanship for a period of one year after date of purchase. See printed warranty for details. Everpure will provide a copy of the warranty upon request.
The contaminants or other substances removed or reduced by this drinking water system are not necessarily in your water. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
NO09
Loading...