VARIABLE SPEED PUMPS

INSTALLATION AND

USER’S GUIDE

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Translated versions of this manual are available online at / La versión en español de este manual del producto, se puede encontrar en línea a / La version française de ce manuel est disponible à : https://www.pentair.com/en/products/pool-spa-equipment/pool-pumps/superflo_vs_variablespeedpump.html https://www.pentair.com/en/products/pool-spa-equipment/pool-pumps/superflo-vst-pump.html https://www.pentair.com/en/products/pool-spa-equipment/pool-pumps/supermax_vs_variablespeedpump.html

i

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT NOTICE

This guide provides installation and operation instructions for this pump. Consult Pentair with any questions regarding this equipment.

Attention Installer: This guide contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment after installation or left on or near the pump.

Attention User: This manual contains important information that will help you in operating and maintaining this product. Please retain it for future reference.

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

 

 

 

This is the safety alert symbol. When you see this

 

 

 

symbol on your system or in this manual, look for

 

 

 

one of the following signal words and be alert to the

 

 

 

potential for personal injury.

 

 

 

Warns about hazards that can cause death, serious

 

 

 

 

 

 

personal injury, or major property damage if ignored.

 

 

 

Warns about hazards that may cause death, serious

 

 

 

 

 

 

 

personal injury, or major property damage if ignored.

 

 

 

 

 

Warns about hazards that may or can cause minor

 

 

 

 

 

 

 

personal injury or property damage if ignored.

 

 

NOTE

 

Indicates special instructions not related to

 

 

 

hazards.

Carefully read and follow all safety instructions in this manual and on equipment. Keep safety labels in good condition; replace if missing or damaged.

When installing and using this electrical equipment, basic safety precautions should always be followed, include the following:

FAILURE TO FOLLOW ALL INSTRUCTIONS AND

WARNINGS CAN RESULT IN SERIOUS BODILY INJURY OR DEATH. THIS PUMP SHOULD BE INSTALLED AND SERVICED

ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL. INSTALLERS, POOL OPERATORS AND OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS IN THE OWNER’S MANUAL BEFORE USING THIS PUMP. THESE WARNINGS AND THE OWNER’S MANUAL MUST BE LEFT WITH THE POOL OWNER.

Do not permit children to use this product.

RISK OF ELECTRICAL SHOCK. Connect only to a branch circuit protected by a ground-fault circuitinterrupter (GFCI). Contact a qualified electrician if you cannot verify that the

circuit is protected by a GFCI.

This unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested

on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a qualified service representative before using.

This pump is for use with permanent swimming pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently-installed pool is

constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity.

General Warnings

Never open the inside of the drive or motor enclosure. There is a capacitor bank that holds a 230 VAC charge even when there is no power to the unit.

The pump is not submersible.

The pump is capable of high flow rates; use caution when installing and programming to limit pumps performance potential with old or questionable equipment.

Code requirements for electrical connection differ from country to country, state to state, as well as local municipalities. Install equipment in accordance with the National Electrical Code and all applicable local codes and ordinances.

Before servicing the pump; switch OFF power to the pump by disconnecting the main circuit to the pump.

This appliance is not intended for use by persons (including children) of reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

SUCTION ENTRAPMENT HAZARD: STAY OFF

THE MAIN DRAIN AND AWAY FROM ALL SUCTION OUTLETS! THIS PUMP IS NOT EQUIPPED WITH SAFETY VACUUM

RELEASE SYSTEM (SVRS) PROTECTION AND DOES NOT PROTECT AGAINST BODY OR LIMB ENTRAPMENTS, DISEMBOWELMENTS (WHEN A PERSON SITS ON A BROKEN OR UNCOVERED POOL DRAIN) OR HAIR ENTANGLEMENTS.

THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG VACUUM AT THE MAIN DRAIN AT THE BOTTOM OF THE BODY OF WATER. THIS SUCTION IS SO STRONG THAT IT CAN TRAP ADULTS OR CHILDREN UNDER WATER IF THEY COME IN CLOSE PROXIMITY TO A DRAIN OR A LOOSE OR BROKEN DRAIN COVER OR GRATE.

THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN COVERS ARE MISSING, CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR ENTANGLEMENT, BODY ENTRAPMENT, EVISCERATION AND/OR DEATH.

The suction at a drain or outlet can cause:

Limb Entrapment: When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling. This hazard is present when a drain cover is missing, broken, loose, cracked or not properly secured.

Hair Entanglement: When the hair tangles or knots in the drain cover, trapping the swimmer underwater. This hazard is present when the flow rating of the cover is too small for the pump or pumps.

Body Entrapment: When a portion of the body is held against the drain cover trapping the swimmer underwater. This hazard is present when the drain cover is missing, broken or the cover flow rating is not high enough for the pump or pumps.

Evisceration/Disembowelment: When a person sits on an open pool (particularly a child wading pool) or spa outlet and suction is applied directly to the intestines, causing severe intestinal damage. This hazard is present when the drain cover is missing, loose, cracked, or not properly secured.

Mechanical Entrapment: When jewelry, swimsuit, hair decorations, finger, toe or knuckle is caught in an opening of an outlet or drain cover. This hazard is present when the drain cover is missing, broken, loose, cracked, or not properly secured.

NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN ACCORDANCE WITH THE LATEST NATIONAL AND LOCAL CODES, STANDARDS AND GUIDELINES.

SUPERFLO® VST, SUPERFLO® VS and SUPERMAX® VS Variable Speed Pumps Installation and User’s Guide

ii

IMPORTANT SAFETY INSTRUCTIONS

TO MINIMIZE THE RISK OF INJURY DUE TO

SUCTION ENTRAPMENT HAZARD:

A properly installed and secured ANSI/ASME A112.19.8 approved antientrapment suction cover must be used for each drain.

Each suction cover must be installed at least three (3’) feet apart, as measured from the nearest point to nearest point.

Regularly inspect all covers for cracks, damage and advanced weathering.

If a cover becomes loose, cracked, damaged, broken or is missing, replace with an appropriate certified cover.

Replace drain covers as necessary. Drain covers deteriorate over time due to exposure to sunlight and weather.

Avoid getting hair, limbs or body in close proximity to any suction cover, pool drain or outlet.

Disable suction outlets or reconfigure into return inlets.

The pump can produce high levels of suction within the suction side of the plumbing system. These high levels of suction can pose a risk if a person comes within the close proximity

of the suction openings. A person can be seriously injured by this high level of vacuum or may become trapped and drown. It is absolutely critical that the suction plumbing be installed in accordance with the latest national and local codes for swimming pools.

A clearly labeled emergency shut-off switch for the pump must be in an easily accessible, obvious place. Make

sure users know where it is and how to use it in case of emergency.

The Virginia Graeme Baker (VGB) Pool and Spa Safety Act creates new requirements for owners and operators of commercial swimming pools and spas.

Commercial pools or spas constructed on or after December 19, 2008, shall utilize:

(A) A multiple main drain system without isolation capability with suction outlet covers that meet ASME/ANSI A112.19.8a Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs and either:

(i)A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 Manufactured Safety Vacuum Release systems (SVRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub, and Wading Pool Suction Systems and/or ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release Systems (SVRS) for Swimming pools, Spas and Hot Tubs or

(ii)A properly designed and tested suction-limiting vent system or

(iii)An automatic pump shut-off system.

Commercial pools and spas constructed prior to December 19, 2008, with a single submerged suction outlet shall use a suction outlet cover that meets ASME/ANSI A112.19.8a and either:

(A)A SVRS meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or

(B)A properly designed and tested suction-limiting vent system, or

(C)An automatic pump shut-off system, or

(D)Disabled submerged outlets, or

(E)Suction outlets shall be reconfigured into return inlets.

For Installation of Electrical Controls at Equipment

Pad (ON/OFF Switches, Timers and Automation Load Center)

Install all electrical controls at equipment pad, such as

on/off switches, timers, and control systems, etc. to allow

the operation (startup, shut-down, or servicing) of any pump or filter so the user does not place any portion of his/her body over or near the pump strainer lid, filter lid or valve closures.

This installation should allow the user enough space to stand clear of the filter and pump during system start-up, shut down or servicing of the system filter.

HAZARDOUS PRESSURE: STAND CLEAR OF PUMP AND FILTER DURING START UP.

Circulation systems operate under high pressure. When

any part of the circulating system (i.e. locking ring, pump,

filter, valves, etc.) is serviced, air can enter the system and become pressurized. Pressurized air can cause the pump housing cover, filter lid, and valves to violently

separate which can result in severe personal injury or death. Filter tank lid and strainer cover must be properly secured to prevent violent separation. Stand clear of all circulation system equipment when turning on or starting up pump.

Before servicing equipment, make note of the filter pressure. Be sure that all controls are set to ensure the system cannot inadvertently start during service. Turn off all power to the pump. IMPORTANT: Place filter manual air relief valve in the open position and wait for all pressure in the system to be relieved.

Before starting the system, fully open the manual air relief valve and place all system valves in the “open” position to allow water to flow freely from the tank and back to the tank. Stand clear of all equipment and start the pump.

IMPORTANT: Do not close filter manual air relief valve until all pressure has been discharged from the valve and a steady stream of water appears. Observe filter pressure gauge and be sure it is not higher than the pre-service condition.

General Installation Information

Allworkmustbeperformedbyaqualifiedserviceprofessional,and must conform to all national, state, and local codes.

Installtoprovidedrainageofcompartmentforelectricalcomponents.

Theseinstructionscontaininformationforavarietyofpumpmodels and therefore some instructions may not apply to a specific model. All models are intended for use in swimming pool applications. The pump will function correctly only if it is properly sized to the specific application and properly installed.

Pumps improperly sized or installed or used in applications other than for which the pump was intended can result in severe personal injury or death. These risks may

include but not be limited to electric shock, fire, flooding, suction entrapment or severe injury or property damage caused by a structural failure of the pump or other system component.

Pumps and replacement motors that are single speed and one (1) Total HP or greater cannot be sold, offered for sale, or installed in a residential pool for filtration use in California, Title 20 CCR sections 1601-1609.

Warning Page P/N 352557 Rev. D 11/19

SUPERFLO® VST, SUPERFLO® VS and SUPERMAX® VS Variable Speed Pumps Installation and User’s Guide

iii

CUSTOMER SERVICE / TECHNICAL SUPPORT

If you have questions about ordering Pentair replacement parts, and pool products, please contact:

Customer Service and Technical Support, USA

Sanford, North Carolina (8 A.M. to 5 P.M. ET)

(8 A.M. to 5 P.M. — Eastern/Pacific Times)

Phone: (919) 566-8000

Phone: (800) 831-7133

Fax: (919) 566-8920

Fax: (800) 284-4151

Moorpark, California (8 A.M. to 5 P.M. PT)

Web site

Phone: (805) 553-5000 (Ext. 5591)

Visit www.pentair.com for more information about

Fax: (805) 553-5515

Pentair products.

 

TABLE OF CONTENTS

Important Safety Instructions ...........................

i

Introduction ........................................................

1

Pump Features

1

Motor Features

1

Drive Features

1

External Control

1

Using the Drive Keypad ....................................

2

Installation ..........................................................

3

Location

3

Piping

3

Fitting and Valves

3

Electrical Installation

4

Wiring

4

Grounding

4

Bonding

4

External Control via RS-485

5

Control System Pump Settings

5

External Control via Digital Inputs

6

Using the Pump's Output Signal

6

Using an External Input Signal

7

External Control Only Mode

7

Operation ............................................................

8

Setting the Clock and Pump Address

8

Using the Default Schedule

8

Programming a Custom Schedule

9

Speed Priorities (Non-External Control)

10

Operating the Pump While Running

10

Quick Clean

10

Priming

11

Programming Quick Clean

12

Keypad Lockout

12

Factory Reset

13

Maintenance .......................................................

14

Cleaning the Pump Strainer Basket

14

Winterizing

14

Servicing .............................................................

15

Motor Care

15

Pump Disassembly

15

Shaft Seal Replacement

16

Pump Reassembly

16

Restarting the Pump

17

Troubleshooting .................................................

18

Troubleshooting Chart

18

Alarms and Fault Codes

19

Replacement Parts ............................................

20

Pumps Manufactured AFTER 11/02/20

20

Pumps Manufactured BEFORE 11/02/20

21

Technical Data ....................................................

22

Performance Curves

22

Specifications and Dimensions

22

SUPERFLO® VST, SUPERFLO® VS and SUPERMAX® VS Variable Speed Pumps Installation and User’s Guide

1

INTRODUCTION

The perfect choice for all types of pools, SuperFlo® VST, SuperFlo® VS and SuperMax® VS Variable Speed Pumps are designed to be your best choice for a variety of inground pools.

The thick walled pump body, permanent magnet motor, and highly engineered hydraulics make this rugged and tested design perfect for any pool, spa, water feature, or fountain.

All Pentair pumps incorporate innovative hydraulic engineering that has been refined for over 40 years.

Compact, rugged, and easy to maintain, this pump will deliver years of reliable service.

Pump Features

Extremely quiet operation

Unionized fittings (1.5” and 2”) for simple replacement

See-through strainer pot lid allows easy inspection of strainer basket

Self-priming for quick, easy start-up

WEF 9.0 THP 2.2

Motor Features

High-Efficiency Permanent Magnet Motor

56 Square Flange

Totally Enclosed Fan Cooled (TEFC)

Drive Features

The pump features a premium efficiency variable frequency drive that provides flexibility in terms of motor speed and duration settings.

This pump is for use with 115/208-230 Vrms nominal, and in pool pump applications ONLY. Connection to the wrong voltage, or use in other applications may cause damage to

equipment or personal injury.

The pump's drive controls the speed settings as well as run durations. The pump can operate at speeds ranging between 450 and 3450 RPM and will operate within the voltage range of 115-230 Vrms nominal at either 50 or 60Hz input frequency.

The pump is intended to run at the lowest speeds needed to maintain a sanitary environment and, at the same time, minimize energy consumption. Factors such as pool size, the presence of additional water features, type of chemicals used to maintain sanitary conditions, and local environmental factors will impact optimal programming to maximize energy conservation. Determining the optimal settings and programming for your pool may require some trial-and-error.

Simple user interface

UV and rain-proof enclosure

Onboard time of day schedule

Adjustable priming mode

Programmable Quick Clean mode

Pump alarm display and retention

Accepts 115-230V, 50/60Hz input power

Auto power limiting protection circuit

24hr. clock retention for power outages

Keypad lockout mode

External Control

This pump can be externally controlled via digital inputs using the Digital Input Wiring Kit (P/N 353129Z - Almond) or the RS-485 Automation Wiring Kit (P/N 356324Z - Black). See External Control via Digital Inputs, page 6.

SuperFlo VST and SuperMax VS pumps can be externally controlled by most Pentair control systems via an RS-485 connection using the RS-485 Automation Wiring Kit (P/N 356324Z - Black). The pump address and other settings can be programmed from the pump's keypad. See External Control via RS-485, page 5.

When connected to external controls, the pump will prioritize commands as follows:

RS-485 > Digital Inputs > Drive Programmed Schedule

Refer to the control system manual for further details on how to connect and program your pump with your control system.

SUPERFLO® VST, SUPERFLO® VS and SUPERMAX® VS Variable Speed Pumps Installation and User’s Guide

2

USING THE DRIVE KEYPAD

Before operating the pump for the first time, the pump’s internal clock and operational schedules must be programmed.

Refer to Setting the Clock and Pump Address, page 8 and Programming Custom Schedules, page 9 for instructions regarding the programming of this pump for scheduled operation.

The pump can be programmed and controlled from the drive keypad. Pump features and settings are also accessed using this keypad.

Note: Functionality may vary based on other active features such External Control Only Mode and/or Keypad Lockout.

Note: Always close the keypad cover after use. This will prevent damage to the keypad and other drive components.

Only press keypad buttons with your fingers. Using screwdrivers, pens or other tools to program the pump will damage the keypad.

If power is connected to the pump motor, pressing any of the following buttons referred to in this section could result in the motor starting. Failure to recognize this could result in personal injury or damage to equipment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(5) Display Parameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEDs

(1) SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(6) Display Button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Buttons

 

 

 

 

 

 

 

 

 

(2) External Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Only LED

 

 

 

 

 

 

 

(7) Quick Clean Button

 

 

 

 

 

 

 

(3) Start/Stop LED

 

 

 

 

 

 

 

 

 

(8) Power LED

 

 

 

 

 

 

 

 

(4) Start/Stop Button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(9) “+” and “-” Arrows

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.SPEED Buttons - Used to select a desired speed program. When the LED above a SPEED Button is illuminated that program has been selected or is currently running. A blinking LED indicates that an External Control has activated that program.

2.External Control Only LED - Indicates whether the pump is in External Control mode. When LED is illuminated the drive-programmed schedules are disabled and only commands from digital inputs will be acted upon.

3.Start/Stop LED - Indicates whether the pump is in a Start State. When illuminated the pump can be started at any time by external controls, drive-programmed schedules or manual inputs. When the pump is stopped and the LED is not illuminated, the pump is unable to run from any type of input.

4.Start/Stop Button - Used to start and stop the pump. When the pump is stopped and the Start/Stop LED is not illuminated, the pump is unable to run from any input.

5.Display Parameter LEDs - When illuminated, LED indicates the information being displayed on screen. A blinking LED indicates that the parameter is currently being edited.

6.Display Button - Used to toggle between the different available display modes. This button is also used to set the clock, screen brightness and pump address.

7.Quick Clean Button - Used to run the speed and duration programmed for Quick Clean. When the LED above the Quick Clean Button is illuminated a Quick Clean cycle is active.

8.Power LED - When illuminated, LED indicates that there is live power being supplied to the pump.

9.“+” and “-” Arrows - Used to make adjustments to the pump settings. The “+” arrow increases a value, while “-” decreases a value. Pressing and holding either arrow button will increase or decrease incremental changes faster.

SUPERFLO® VST, SUPERFLO® VS and SUPERMAX® VS Variable Speed Pumps Installation and User’s Guide

3

INSTALLATION

Only a qualified plumbing professional should install the pump. Refer to IMPORTANT SAFETY INSTRUCTIONS on page i-ii for additional installation and safety information.

Location

Note: Do not install this pump within an outer enclosure or beneath the skirt of a hot tub or spa unless marked accordingly.

Note: Ensure that the pump is mechanically secured to the equipment pad.

ENSURE THE INSTALL LOCATION MEETS THE FOLLOWING REQUIREMENTS:

1.Install the pump as close to the pool or spa as possible. To reduce friction loss and improve efficiency, use short, direct suction and return piping.

2.Install a minimum of 5 ft. (1.5 m) from the inside wall of the pool and spa. Canadian installations require a minimum of 9.8 ft. (3 m) from the inside wall of the pool.

3.Install the pump a minimum of 3 ft. (0.9 m) from the heater outlet.

4.Do not install the pump more than 10 ft. (3.1 m) above the water level.

5.Install the pump in a well ventilated location protected from excess moisture (i.e. rain gutter downspouts, sprinklers, etc.).

Figure 1

6 IN. (15.2 CM)

 

 

MINIMUM

 

3 IN.

 

MINIMUM

Figure 2

5 x SUCTION PIPE DIAMETER

ELBOW

6.Install the pump with a rear clearance of at least

3 inches (7.6 cm) so that the motor can be removed easily for maintenance and repair. See Figure 1.

Piping

1.For improved pool plumbing, it is recommended to use a larger pipe size.

2.Piping on the suction side of the pump should be the same or larger than the return line diameter.

3.Plumbing on the suction side of the pump should be as short as possible.

4.For most installations Pentair recommends installing a valve on both the pump suction and return lines so that the pump can be isolated during routine maintenance. However, we also recommend that a

valve, elbow or tee installed in the suction line should be no closer to the front of the pump than five (5) times the suction line diameter. See Figure 2.

Example: A 2.5" pipe requires a 12.5" (31.8 cm) straight run in front of the suction port. This will help the pump prime faster and last longer.

Note: DO NOT install 90° elbows directly into the suction or discharge ports.

Fittings and Valves

1.Do not install 90° elbows directly into suction port.

2.Flooded suction systems should have gate valves installed on suction and discharge pipes for maintenance, however, the suction gate valve

should be no closer than five times the suction pipe diameter as described in this section.

3.Use a check valve in the discharge line when using this pump for any application where there is significant height to the plumbing after the pump.

4.Be sure to install check valves when plumbing in parallel with another pump. This helps prevent reverse rotation of the impeller and motor.

SUPERFLO® VST, SUPERFLO® VS and SUPERMAX® VS Variable Speed Pumps Installation and User’s Guide

Pentair SUPERFLO VST, SUPERFLO VS STA-RITE, SUPERMAX VS Installation Manual

4

Electrical Installation

RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. The pump must be installed by a licensed or certified electrician or a qualified service professional in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to users, installers, or others due to electrical shock, and may

also cause damage to property.

Always disconnect power to the pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to service people, pool users or others due to electric shock and/or property damage.

Read all servicing instructions before working on the pump.

The pump accepts 115-230 V, 50 or 60 Hz single phase input power. Power Connections (Figure 3) are capable of handling up to 10 AWG solid or stranded wire.

The motor controller will automatically regulate the pump speed when running on lower voltage to keep current below 13.6 A. No wiring change is required to run the pump on 115 V nominal power, the same terminals are used as with high voltage wiring.

The drive will operate on 2-Phase Line-Line-Ground electrical systems as well as Line-Neutral-Ground systems.

Wiring

1.Ensure all electrical breakers and switches are turned off before wiring the motor.

Grounding

1.Permanently ground the motor using the Grounding Terminal (Figure 3) inside the drive wiring compartment. Refer to the current National Electrical Code and any local codes for wire size and type requirements. Ensure the ground wire is connected to an electrical service ground.

2.ONLY connect the pump to a supply circuit protected by a ground-fault circuit-interrupter (GFCI) circuit breaker.

Note: Pentair offers a 2-Pole 20 Amp GFCI breaker

(P/N PA220GF).

Note: The pump should be wired to its own independent circuit unless the pump is operated in tandem with a Pentair salt chlorine generator.

STORED CHARGE - Wait at least 5 minutes before servicing.

2.Ensure supply voltage meets the requirements listed on the motor nameplate.

3.For wiring sizes and general requirements, follow specifications defined by the current National

Electric Code and any local codes. When in doubt use a heavier gauge (larger diameter) wire.

4.Ensure all electrical connections are clean and tight.

5.Cut all wiring to the appropriate length so they do not overlap or touch when connected to terminals.

6.ALWAYS reinstall the drive lid after electrical installation or before leaving the pump unsupervised during servicing. This will prevent rainwater, dust or other foreign matter from accumulating in the drive.

Note: Ensure wires are not pinched between the drive body and lid.

Bonding

1.Using the Bonding Lug located on the side of the motor (Figure 3), bond the motor to all metal parts of the pool structure, electrical equipment, metal conduit and metal piping within 5 ft. (1.5 m) of the inside walls of the swimming pool, spa or hot tub in accordance with the current National Electrical Code and any local codes.

2.Solid copper bonding conductor of 8 AWG or larger is required. For Canadian installations, 6 AWG or larger solid copper bonding conductor is required.

 

 

Bonding

 

 

Lug

 

 

Power

 

Grounding

Connections

Figure 3

Terminal

 

SUPERFLO® VST, SUPERFLO® VS and SUPERMAX® VS Variable Speed Pumps Installation and User’s Guide

External Control via RS-485

The following instructions only apply to SuperFlo® VST and SuperMax® VS pumps manufactured after 10/15/20. For all other pumps, refer to External Control via Digital Inputs on page 6.

These pumps can be controlled from certain Pentair control systems, via an RS-485 signal, when paired with the RS-485 Automation Wiring Kit (P/N 356324Z - Black).

Note: IntelliConnect® Control and Monitoring Systems can NOT externally control this pump via RS-485. The pump will need to be connected via digital inputs. Refer to External Control via Digital Inputs on page 6.

Note: If the pump is manually stopped using the Start/Stop button, the pump will not run until the Start/Stop button is pressed. If the Start/Stop LED is illuminated, the pump is active and can be controlled externally.

Only the GREEN and YELLOW conductors will be used to wire the pump for external control via RS-485. See

Figure 4.

Automation System

Note: Only the GREEN and

YELLOW wires will be used. All

COM Port

other wires should be cut off at the

<![if ! IE]>

<![endif]>3 4

cable sheath.

 

YELLOW

 

<![if ! IE]>

<![endif]>2

GREEN

From

<![if ! IE]>

<![endif]>1

 

Pum

 

 

RS-485 Automation Kit (P/N 356324Z - Black)

Figure 4

Control System Pump Settings

Pump Type: Variable Speed (VS)

Control systems with older firmware may require the pump be designated "IntelliFlo VS".

This pump will not process control system commands if designated a Variable Flow (VF) or Variable Speed/ Flow (VSF) pump.

Pump Address: 1 or 2

Ensure the assigned pump address matches the pump address in the control system. Refer Setting the Clock and Pump Address, page 8.

Refer to the control system manual for more information on connecting and programming your pump.

5

TO WIRE FOR EXTERNAL CONTROL USING RS-485:

1.Route the communication cable from the Pump Com Port (Figure 5) to the control system wiring compartment.

2.Ensure the cable reaches all necessary terminals and cut to the necessary length.

3.Strip the cable 3/4" (19 mm).

4.Strip the 24 AWG GREEN and YELLOW conductors 1/2" (13 mm).

5.Cut back and terminate unused conductors according to local and national electrical codes.

6.Connect YELLOW and GREEN conductors to the control system as shown in Figure 4.

7.Program the pump's internal clock. Refer to Setting the Clock and Pump Address on page 8.

8.Program SPEED 1 to a speed of 0 RPM and duration of 24 hours. Refer to Programming Custom Schedules on page 9.

9.Disable priming at the pump. Priming duration and speeds will be controlled by the control system.

Note: If priming is not disabled at the pump, priming will be continue to be controlled by the pump. Refer to Priming on page 11.

10.Plug the communication cable into the Pump Com Port (Figure 5).

Pump Com

Port

Figure 5

SUPERFLO® VST, SUPERFLO® VS and SUPERMAX® VS Variable Speed Pumps Installation and User’s Guide