1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000
Trademarks and Disclaimers:
System 2™, Posi-Lok™,Sta-Rite
Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/or other counties. Unless noted, names
and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the
proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the
trademarks or registered trademarks of those parties or others. Printed in U.S.A.
4-19-12S338 (Rev. B)
®
and Pentair Water Pool and Spa®are trademarks and/or registered trademarks of Pentair
This manual should be given to the
owner of this filter.
Repair Parts List ............................................................................................11
READ AND FOLLOW SAFETY
INSTRUCTIONS!
This is the safety alert symbol. When you see this symbol on your filter or in
this manual, look for one of the following signal words and be alert to the
potential for personal injury.
WARNING
Hazardous Pressure!
Can cause tank
explosion.
Do not connect filter to
compressed air under any
circumstances.
warns about hazards that will cause death, serious personal injury,
or major property damage if ignored.
warns about hazards that can cause death, serious personal injury,
or major property damage if ignored.
warns about hazards that will or can cause minor personal injury or
property damage if ignored.
NOTICE indicates special instructions not related to hazards.
Carefully read and follow all safety instructions in this manual and on equipment.
Keep safety labels in good condition; replace if missing or damaged.
Incorrectly installed or tested equipment may fail, causing
severe injury or property damage. Read and follow instructions in
owner's manual when installing and operating equipment. Have a
trained pool professional perform all pressure tests.
1. Do not connect system to a city water system or other external source of
pressurized water.
2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE all air is out of system
before operating or testing equipment.
Before pressure testing, make the following safety checks:
• Check all clamps, bolts, lids, lock rings and system accessories before testing.
• Release all air in system before testing.
• Tighten Sta-Rite pump trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing.
• Water pressure for test must be less than 25 PSI (172 kPa).
• Water Temperature for test must be less than 100
• Limit test to 24 hours. After test, visually check system to be sure it is ready for
operation. Remove pump trap lid and retighten hand tight only.
NOTICE: These parameters apply to Sta-Rite equipment only. For
non-Sta-Rite equipment, consult equipment manufacturer.
o
F. ( 38oC).
2
When to Clean the Filter
The filter module should normally be
cleaned when the pressure gauge
reading increases 10 PSI over the startup pressure (record the start-up
pressure under “Owner’s Information”,
below, right).
In some pools, accessories such as
fountains or pool cleaners may be
noticeably affected by the normal
decrease in flow as the filter becomes
dirty. If so, clean the filter more
frequently (that is, at a pressure increase
of less than 10 PSI) in order to maintain
the required flow.
GENERAL INFORMATION
• Clean a new pool as well as possible before filling pool and operating
filter. Excess dirt and large particles of foreign matter in the system can
cause serious damage to the filter and pump.
• With a permanent media filter in place and operating correctly, clean water
is returned to the pool faster than pool water is being contaminated. A
typical pool installation will require approximately one week to obtain and
maintain the sparkle that your filter is capable of giving you.
• Maximum pressure is 50 PSI (345 kPa). DO NOT connect the filter to a
city water system or to an individual water well system.
Hazardous pressure. Open air release valve to vent all air
from system before operating system. NEVER operate filter with air
trapped inside.
®
• The Sta-Rite
pools and spas. On a new installation, we recommend:
1. Disassemble the filter after the initial cleanup.
property damage, exactly follow "Filter Disassembly/Assembly
Procedure" on Pages 6 and 7.
2. Remove and hose down the element assembly to remove contaminants.
• Maintain pool water pH between 7.2 and 7.6.
• Make sure that internal air bleed tube and filter are clean and installed
properly at top of module before operating filter.
• Make sure that Posi-Lok™ Ring is securely locked in place before
operating filter.
• Maintain pressure gauge in good working order. Replace a damaged
gauge immediately.
modular media filter is designed to filter water for swimming
Hazardous pressure. To prevent severe injury or major
WARNING
He
a
d
rmAeorF
pper
Arm
U
B
o
d
y
Leg
Jo
Head
B
ody
Risk of drowning and
falls. Place equipment
at least 4 feet from pool
so that children cannot
climb over it into pool.
sss
Do not allow children
to stand or play on filter
or pump.
int
t
Join
L
g
e
eL
gJoin
t
• Cleaning interval is based on pressure rise, not on length of time filter is
operated. Different water conditions will have different normal cleaning
intervals.
• Check local codes for restrictions on waste water disposal requirements.
NOTICE: Some pool disinfectants may clog filter module. To maximize
module life and filter cycle time, closely follow disinfectant manufacturer’s
instructions when cleaning pool or filter. Failure to follow these instructions
may affect warranty coverage of the module.
Owner’s Information
Serial Number ______________________________________________
Purchase Date ______________________________________________
Pressure Gauge Reading at Startup _____________________________
Installation Date _____________________________________________
3
SPECIFICATIONS
4 (28)
2 (14)
6 (41)
8 (55)
10 (69)
12 (88)
14 (97)
16 (110)
18 (124)
Pressure Drop in
Pounds per Square Inch (kPa)
10
(38)
20
(76)
40
(151)
60
(227)80(303)
100
(378)
120
(454)
140
(529)
160
(606)
Flow in Gallons Per Minute (LPM)
20 (138)
150
(568)
Air Release Valve
(Pressure Gauge
Behind)
Upper
Tank
Shell
Posi-Lok™
Ring
Safety
Latch
Lower
Tank
Shell
2" NPT
Inlet or
Drain
Drain
Plug
Outlet
2" NPT
18.58" Dia.
(472 mm)
15" Dia.
(381 mm)
Inlet
or Drain
2" NPT
2.25"
(57 mm)
Minimum
Dim A
4310 0203
Dim B
Service
Height
Filter
R
R
E
E
L
L
E
E
A
A
S
S
E
E
Inlet
Outlet
T
T
E
E
L
L
N
N
I
I
To Pool
From
Pool
FIGURE 1B – Piping Connections
Pump
4085 1001
FIGURE 1A – Dimensions in inches (mm)
Table 1 - Filter Specifications
Filter Area sq. ft. (m
Max. Rated Flow GPM (LPM)
Commercial37(140)47(178)56(212)66(249)75(284)113(428)
Max. Operating Pressure PSI (kPa)50(345)50(345)50(345)50(345)50(345)50(345)
Max. Continuous Water
Temperature F(C)104°(40°)104°(40°)104°(40°)104°(40°)104°(40°)104°(40°)
Dimension A – Height (mm)27-3/4(705) 27-3/4(705) 27-3/4(705) 27-3/4(705) 27-3/4(705) 37-5/8(956)
Dimension B – Minimum Service