Pentair thanks you for placing your trust in the company and purchasing a SPEEDEO®, the variable speed pump control automaton, with 3
assignable pieces of equipment. SPEEDEO® will start up the correct speed of the connected variable speed pump according to the hydraulic
requirements linked to the event.
Please carefully read this user manual to fully benet from all of the functions of SPEEDEO®. Store it carefully so that it can be consulted at any
time.
Declaration of conformity
Directives – Harmonised standards
Pentair International Sarl - Avenue de Sévelin 18 - 1004 Lausanne - Switzerland
We declare, under our own responsibility, that the product meets the directives
SAFETY EN 61010-1:2010
EM EN 61326-1: EN 301 489-3
EMF EN 62311
RADIO EN 300 220-2
SPEEDEO (+ PARTS)
SB-PF-SPO-003C
Other normative documents
PART NUMBERS:
SB-SE-TEC-006A
Authorised person for technical documentation
Pentair International S.a.r.l
Avenue de Sévelin 18
1004 Lausanne - Switzerland
Lausanne, 01/04/2019
Guillaume Goussé
European Vice President of Operations
Product specications: SB-PF-SPO-003C model
Operating temperature: 0° to 40° C Operating hygrometry: 40% at 75° C Power supply: 230 V ~, 50 Hz
Maximum operating altitude: 2000 m Weight (excluding probes): 1.2 kg
Main box (internal use): IP 64
Waste treatment of electronic devices at the end of their service life:
The crossed-out bin placed on the main parts which make up the product indicates that it must not be disposed of with household
waste. It must be returned to an appropriate collection point for electronic device recycling (information available from the local
household waste collection service). This product contains potentially dangerous substances which may have adverse effects on the
environment and human health.
Customer Support: PISA, ITALY (8:30 A.M. to 4:30 P.M.) CET website: www.pentairpooleurope.com
- Warranty (excluding probes and consumables): 2 years
Trademarks and disclaimers: Speedeo®, Soleo® and Pentair® are trademarks and/or registered trademarks of Pentair and/or its aliated
companies. Unless indicated otherwise, names and brands of others that may be used in this document are not used to indicate an aliation or
endorsement between the owners of these names and brands and Pentair. Those names and brands may be the trademarks or the registered
trademarks of these parties, or others.
Summary
PRESENTATION
> Possibilities for a pump with variable speeds
> Packaging contents / Functions of the device
> Description
INSTALLATION - SPECIFIC POINTS
> Fixing connections / hygiene
> Examples of installation types
> Water and air temperature probes
> Connection of IntelliFlo to IntelliBUS and other pumps with variable speeds
> Invertek convertor connection
MENUS
> Main menu / Radio menu
> Install / Heating pump / Information menu
> Filtration Length
> Filtration Speed / Set Time
p 04
p 06
p 06
p 07
p 09
p 10
p 11
p 13
p 14
p 15
p 16
p 17
CONNECTIONS Inlets / Outlets
> Inlet: connection for the end of a cover line / switch or remote control
> Outlet: connections for a controller and an IntelliChlor
> Outlet: connections for heating pump and solar heating
> Outlet: connections for lighting and a 3-way motorised valve
> Outlet: connections and automatic washing for a pneumatic valve
> Washing assisted by 6-way valve
> Navigating the menus
OTHERS
> Updating internal rmware / History menu
> pH / RedOx / chlorine ratio
p 18
p 19
p 20
p 22
p 23
p 24
p 25
p 27
p 28
01
IMPORTANT SAFETY GUIDELINES, READ AND FOLLOW ALL OF THE INSTRUCTIONS, KEEP THESE INSTRUCTIONS
GENERAL POINTS
- DANGER - INSTALLERS, POOL SPECIALISTS AND OWNERS MUST CAREFULLY READ THESE WARNINGS AND ALL
INSTRUCTIONS BEFORE USING THIS PRODUCT.
- WARNING - Most countries regulate the construction, installation and operation of public swimming pools and spas, and the construction of
residential pools and spas. It is important to comply with these regulations, many of which directly regulate the installation and use of this product.
Consult your local building and health codes for more information.
- ATTENTION - This installation and user guide contains important information on the installation, operation and safety of this product. This guide
should be provided to the owner and/or user of this product.
INSTALLATION
- DANGER - RISK OF ELECTRIC SHOCK or electrocution
BEFORE WORKING ON THIS DEVICE - Always cut the supply to the device at the circuit breaker before maintenance. Failure to do this may lead to
death or serious injury to service staff, pool users or others, due to an electric shock.
- DANGER - SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT IS NOT INSTALLED AND USED CORRECTLY.
- WARNING - Before installing this product, read and follow the warnings and instructions of this guide. Failing to follow these warnings and
instructions may lead to serious injuries, death or material damage. Refer to www.pentairpooleurope.com for more information linked to this
product.
- WARNING - Connect the device to a differential interrupter. If this system is used to control the underwater lighting devices, a differential
interrupter must be installed upstream of these devices. Conductors downstream of the differential interrupter shall not occupy conduits, junction
boxes or enclosures containing other conductors, except if the conductors are also protected by a differential interrupter. Refer to valid local codes
for more details.
- WARNING - This product must be installed by an authorised or certied electrician or a qualied swimming pool professional. All of the applicable
installation codes and local regulations must also be respected. Poor installation will create an electrical hazard which could result in serious injury
or the death of pool users, installers or others due to electric shocks, and may also cause damage to property.
- DANGER - DISCONNECT THE SUPPLY CONNECTIONS BEFORE WORKING ON THIS DEVICE; ELECTRICAL POWER MAY BE SUPPLIED TO THE RELAY
TERMINALS FROM OTHER SOURCES.
- WARNING – CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the domestic distribution board before
drilling into any pipes. Set rules for all handling related to electrical aspects, water and chemical products. Group the supply pumps and chemical
product tanks in a safe and secured area.
- WARNING - Do not use this product to control an automatic swimming pool cover. There is a risk that swimmers could become trapped under the
cover.
- WARNING – Devices which are not intended for use in single-family dwellings may require additional safety equipment to comply with local
regulations.
- DANGER – Except for remote controls, install components at a minimum of at least 1.5 m (5 feet) from the inside wall of the pool or spa.
- DANGER - This product is intended for use in swimming pool applications only.
- ATTENTION - A sucient equipotential connection (min. 4.5 mm2 recommended), in accordance with local regulations, is obligatory for all metal
components of the swimming pool, including the pool pump. This is necessary for the electrical safety as well as reduction of the corrosion risk.
02
USE
- DANGER - DO NOT LET CHILDREN OPERATE THIS EQUIPMENT.
- WARNING – Strictly respect the safety and handling procedures from the acid manufacturers, including protective measures for hands, body and
eyes during transferring and using acid. Follow the prescribed safety precautions for handling muriatic acid intended for checking the water pH.
Muriatic acid may cause serious physical harm and may damage the swimming pool equipment. Extra care must be taken when installing,
maintaining and operating the acid pump feed systems. Acid is dangerous to handle and should be properly contained, transported, poured, stored
and dispensed.
- WARNING – Check the pH and sanitizer levels of the water before using the pool and make sure the ltration device is not obstructed.
- WARNING – Periodically use an independent pH and chlorine testing kit to ensure that the pH and chlorine is at a safe level. If the pH and Oxidation
Reduction Potential (ORP) or conductivity probes are broken, depleted or dirty with oils, lotions, or other contaminants, they can report inaccurate
results to the system causing incorrect water chemistry, which could harm people or equipment.
- WARNING – Consult the device display daily to ensure there are no alarm messages.
- DANGER – Water temperatures greater than 37.7° C (100° F) are a health hazard. Prolonged immersion in hot water may induce hyperthermia.
Hyperthermia occurs when the internal body temperature exceeds the normal temperature of 37° C (98.6 °F) by several degrees. Hyperthermia may
produce the following effects: (1) Unawareness of impending danger. (2) Failure to perceive heat. (3) Failure to recognise the need to leave the spa.
(4) Physical inability to leave the spa. (5) Harm to the foetus in pregnant women. (6) Unconsciousness leading to the risk of drowning. The use of
alcohol, drugs or medicine is a factor which increases the risk of hyperthermia in hot tubs and spas.
- WARNING - When mixing acid with water, ALWAYS ADD THE ACID TO THE WATER. Never add water to the acid. When adding a chemical product to
the swimming pool, carefully follow the manufacturer instructions.
- DANGER - DO NOT MIX SODIUM HYPOCHLORITE AND MURIATIC ACID.
- DANGER - Keep standard solutions away from children, ensure that the bottles are securely closed, store them in a dry and ventilated location and
do not let them freeze. The pH 4 calibration solution is acidic.
03
Foreword: management possibilities for a pump with variable speed control
SPEEDEO is intended to optimally control (via dry contacts [of which one is shared and one is a controllable
speed contact, a maximum of four]) the different rotation speeds of a variable speed ltration pump. There
are usually 4 speeds: V1, V2, V3, V4. SPEEDEO makes it possible to launch up to 3 pieces of equipment, whose
operation is linked to a speed. The rotation speeds at different speeds are directly pre-set on the control unit
(drive) of the pump. SPEEDEO will therefore select the most appropriate power according to the requirements
to save as much electricity as possibility without impairing the ltration quality.
Max. flow
pump
Min. pump
pump
0
- Speed 1: Permits minimal circulation. Speed V1 is used for frost protection and is selected when the cover is
placed over the pool (if applicable). V1 will function 24h/day if the water T° > +28.0 °C. This speed is therefore
used when there are no bathers in the pool.
- Speed 2: Permits circulation of a larger amount of water when the cover is stowed (if relevant). This speed
is used when there are no bathers in the pool.
- Speed 3: Permits a strong ow of water when an accessory requires it. It is often chosen for a counter-cur-
rent jet, heating, cascade, etc. It is triggered in accordance with the parameters, either by a timer or a wired
remote control.
- Speed 4: Only used for backwashing of the lter. On some pumps, V4 cannot be adjusted and automatically
represents the maximum power.
Example: typical day for a pool at 25.0°C in June in Europe
At night, the curtain is closed.
Filtration runs at the minimum
speed V1 at night. V1 is very
quiet.
costs on average €600 per year
S1
At 9:00 am, the curtain
is manually opened; the
speed automatically
changes to V2.
One 1.5 cv pump
for electricity.
S2
At midday, ltration goes up to V3 for one
hour to ensure the surface is well-skimmed.
In the afternoon, the NAC command and
cascade timer launch the pump at V3.
S3
Backwashing of the
lter (taking a few
minutes) triggers V4.
S4
0 h24 h12 h15 h6 h9 h18 h
Consumption of a classic ltration pumpS1S2S3S4
Consumption is roughly speed squared, so when the rotation regime is divided by 2, the electricity consumption
of a pump is divided by 4! The average prot of SPEEDEO running a VS pump alongside a classic ltration of 1.5 cv
is €450 per year (ERDF base rate in 2015).
04
Functions
Filtration control:
- By calculating the time according to the pool temperature (automatic mode).
- By programming a 24 hour cycle (makes it possible to benet from off hours).
- By integrating the frost protection function (activation of the ltration below 3°C, modiable
value).
- By giving priority to the heating (if the value of this reference exceeds the set value, and if the
ltration is cut, ltration starts in the next 15 minutes).
- Possibility to select the start time and end time of the ltration in automatic mode (to prevent
noise at night). If SPEEDEO is connected to a SOLEO, this function is found on SOLEO.
- Possibility to increase or reduce the ltration time according to the use of the swimming pool
(economical mode = pool with a low number of visitors, turbo mode = pool with a high number of
visitors) or by default + or - 30% (value can be adjusted).
- Possibility to change into “SHOCK” mode (forcing of the ltration and electrolyser for 24 hours).
- Possibility to change the speed according to the position of the pool cover (motorised cover) if
there is a position contact connection on the dedicated inlet.
- Possibility to change the speed according to the position of a command (interrupter, end
position sensor of the motorised cover).
Control of 3 devices:
- By synchronisation with operation of the pump (each connected device will only be authorised
to operate if the ltration runs at a sucient rate).
SPEEDEO also makes it possible to visualise, on its screen (in the technical room):
- time
- water temperature
- operating speed (S1 to S4)
- status of the 3 outlets (S1 S2 S3, ON or OFF)
- air temperature (if second sensor present)
THEREFORE IN SUMMER AND WINTER, YOU NO LONGER NEED TO WORRY ABOUT YOUR
FILTRATION AND YOU LIMIT THE INTERVENTIONS IN THE TECHNICAL ROOM TO A BARE
MINIMUM.
05
Description
SPEEDEO automatically controls the pump rotation speed with variable speed, enabling the function of
programmed or activated events.
FRONT VIEW
Backlit screen
(4 x 20 characters)
Menu navigation buttons
(Esc/Bottom/Top/Valid.)
Manufacturer’s plate
S/N 1234ABCD1234ABCD1234ABCD01
230 V 50 Hz~/IP64/3.2 W
433.4 MHz
Serial number
MADE IN ITALY
Mfg Year
Apr-2019
SB-PF-SPO-003CSB-SE-TEC-006A
QC Passed
Pentair International Sarl
Avenue de Sévelin 18
CH-1004 Lausanne, Switzerland
- This device is intended to be used inside, installed in a technical room which cannot be accessed by
children.
- Set the device at a height lower than 2 m using three screws (4 to 5 mm diameter) in appropriate plugs
for the type of support and x the device vertically on a clean support which is able to bear a minimum
vertical load of 5 kg.
Pierce three holes in accordance with the below dimensions then place 3 suitable plugs.
1 - Tighten the screw at the top, leaving 2 mm under the screw head, then hang the device on this.
2 - Place the 2 lower screws.
3 - Add the 2 lower screw covers to ensure a full seal.
1
m
m
0
5
1
m
m
5
8
1
3
2
A safety cover which cannot be unclipped without a tool is positioned above the connectors which provide
the voltage. > Place a at screwdriver on the at part of clips 2 and 3, while keeping pressure on to unclip it.
After each intervention, replace the
1
2
3
4
orange safety cover then the exible
grey cover.
07
185 mm
150 mm
Electrical connections regulation
- The device must be installed by a qualied technician according to valid local regulation
- This device is permanently connected.
- The power supply to the device is cut by its interrupter, which must be close and must remain
accessible at all times.
- The device needs to be connected to the earth and its power supply needs to be protected by 16A 30
mA differential protection. This protection must be cut before any intervention on the device.
- Overvoltage category II (2,500 V peak) electrical device. If necessary, place overvoltage protection
equipment before the device.
- The device must be placed close to the electrical cabinet to aid connections (3 m max.).
Interchangeable fuse
FST 5x20 250 V AC 1A 5x20 fast
Slotted screwdriver 2.5 mm/0.5-0.6 Nm
Screw terminals
N L
OUT 1
OUT 2
230 V ~
OUT 3
POWER SUPPLY 230 V / 50 Hz +- 10%
OUT 1 - 230 V 10A max.
OUT 2 - 230 V 10A max.
OUT 3 - 230 V 10A max.
The supply cable as well as the cables of the
dry power contacts must be placed in a plated
and closed channel under the device.
Compatible power supply cables 230 VCompatible dry contact cables
= RO2V (3 x 1.5 mm2 min.)= RO2V (2 x 1.5 mm2 min.)
30 mm max. 5 mm
Ø 8/8.8 mm
REAR VIEW
Caps
- must be installed if an outlet is not in use
(to stop any humidity or acidic vapour entering)
Cable ducts
- must be installed if an outlet is in use,
(to stop any humidity or acidic vapour entering)
30 mm max. 5 mm
COMM.
SPEED 1
SPEED 2
SPEED 3
SPEED 4
BUS
IN 1
Ø 8/8.8 mm