Pentair SPA-400 User Manual

EVERPURE SPA400 WATER FILTRATION SYSTEM
SISTEMA DE FILTRACIÓN DE AGUA SPA400 SPA400 SYSTÈME DE FILTRAGE D’EAU
©2017 Pentair Residential Filtration, LLC waterpurification.pentair.com
Thank you for purchasing an Everpure by Pentair commercial­grade water filtration system for your home. With your Everpure by Pentair system, you get premium quality water direct from your tap that’s great-tasting, healthful and convenient for you and your family.
PRODUCT SPECIFICATIONS
• For Cold Water Use Only
• Temperature Range: 35-100°F (2-38°C)
• Min.-Max. Working Pressure: 10-125 psi (0.7-8.6 bar)
ENGLISH
• Service Flow Rate: 2.2 gpm (8.3 Lpm)
• Capacity: 3,000 gallons (11,355 L)
TOOLS REQUIRED FOR INSTALLATION
• Phillips Screwdriver
• Adjustable Wrench
• Tape Measure
• Pencil
BASIC INSTALLATION INSTRUCTIONS
1. Open Carton & Inspect Parts
Installation Parts
Key Description Part No.
1 QL3 Filter Head EV927092 2 SPA-400 Filter Cartridge EV927091 3 2 Locking Washers EV306204 4 2 Screws EV306196 5 3/8-inch MPT x 3/8-inch FTP Elbow EV310852 6 (2) 3/8-inch x 1/2-inch Unions EV312251 7 (2) 3/8-inch x 3/8-inch Unions EV312250 8 Plumber Tape EV312119 9 Everpure Filter Timer EV907570
1
3
4
5
1
7
6
2
9
8
2
20 inches
2. Verify Under-Sink Mounting Location
Measure 20 inches from the base of the cabinet, and mark the mounting location for the top of the filter head. Make sure there is adequate space above the head to open and close the built in shut-off valve and to avoid crimping the water line tubing. Also, make sure your chosen location offers easy access for future cartridge changes.
DIMENSION Width
SPA-400 5 inches 20 inches 5 inches
NOTE: The head and cartridge must be mounted in the
vertical position, with the cartridge hanging down.
3. Mount Filter Head Under Sink
Mounting
Height
Depth
2 • EVERPURE SPA-400 Water Filtration System
BASIC INSTALLATION INSTRUCTIONS
CONTINUED
NOTE: Two sets of unions are included to connect to the 3/8-
inch head connections. If your existing braided tubing has 1/2-inch connections, use the 1/2-inch x 3/8-inch unions instead of the 3/8-inch x 3/8-inch unions. You will have 2 extra fittings with either installation. The following instructions are for a typical installation using 1/2-inch supply lines.
A. Apply plumber tape to the small threads of one Union
Fitting and screw into the open end of the Elbow. Wrap tape in direction of the threads to assure a tight fit and avoid small leaks.
B. Apply plumber tape to the threads of the Elbow Fitting
and screw into the inlet (left) side of the Filter Head. Hand tighten only.
C. Apply plumber tape to the small threads of the second
Union Fitting, and screw into the right side of the filter head in the same manner.
D. Securely mount the filter head on the cabinet wall using
the enclosed mounting screws and washers.
4. Connect Inlet Water Supply
E. Locate and close the cold water shut-off valve under your
sink. Open cold water line of faucet to release water pressure.
F. Unscrew and disconnect the braided tubing on top of cold
water shut-off valve.
G. Attach one end of the new braided tubing to the top of the
cold water shut-off valve.
H. Attach the other end of the new Braided Tubing to the inlet
side of the filter head (Union & Elbow Fittings).
3
A
D
C
B
4
ENGLISH
F
E
H
G
5
I
5. Attach Filtered Water To Cold Line of Faucet
I. Attach open end of existing Braided Tubing to Union Fitting
on outlet side (right) of new Filter Head. Hand tighten to avoid damage to fittings.
6. Install And Flush Filter Cartridge
J. Lift handle of the build-in shut off (QC Valve) on the Head. K. Hold Head firmly with one hand. L. Align cartridge lug with label on filter Head. M. Insert filter Cartridge—Push upwards. N. Turn it to the right—About 1⁄4 turn—Until rotation stops. O. Open cold water valve and check for leaks up to Inlet
Elbow Fitting. P. Open Water Faucet (not pictured). Q. Lower the QC Valve Handle to flush water to the sink.
NOTE: Flush new filter cartridges for at least 3 minutes to
remove air and any loose carbon. At first the water may appear cloudy due to trapped air in the filter and tubing. If water continues to be cloudy for more that one week, please contact Pentair Technical Support for assistance: (800) 279-9404
R. Activate Filter Timer by pinching bubble until you feel
a change in resistance as the Filter timer “pops.”
Within a few seconds, a thin RED line will appear in
the white window showing the Timestrip(R) has been
activated. Peel away backing and adhere to desired
location. When the white window is completely filled
with RED, it is time to replace your product.
6
J
K
L
Label
M
Lug
Q
O
N
EVERPURE SPA-400 Water Filtration System 3
HEALTH CLAIM PERFORMANCE TESTED
WARNING:
& CERTIFIED BY WQA
This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
ENGLISH
Substance
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥ 50% 99%
Particulate, Class I particles
0.5 to <1 µm
Standard 53—Health Effects
Cyst
Lead 8.5 0.15 mg/L ± 10% 0.010 mg/L 99.9% 99.9%
Lead 6.5 0.15 mg/L ± 10% 0.010 mg/L 93.2% 98.5%
Influent
Challenge
Concentration
at least 10,000
particles/mL
Minimum
50,000/L
NOTE: This installation must comply with all applicable state
and local regulations. NOTE: Maximum working pressure 125 psi. NOTE: Do not use with water that is microbiologically unsafe
or unknown quality without adequate disinfection
before or after the system. Systems certified for cyst
reduction may be used on waters that may contain
filterable cysts. NOTE: Testing was performed under standard laboratory
conditions, actual performance may vary. NOTE: This drinking water system must be maintained
according to manufacturer’s instructions, including
replacement of filter cartridges. Suggested retail
$134.99.
Max.
Permissible Product Water Concentration
Reduction
Requirements
≥ 85% 98.3%
99.95% 99.99% 99.99%
Minimum
Reduction
Average
Reduction
This System has been Tested & Certified by WQA against CSA B483.1 and NSF/ANSI 42, 53 as verified and substantiated by test data for the reduction of:
Std. No. 42—Aesthetic effects
Chemical Reduction
Chlorine Taste & Odor
Mechanical Filtration
Nominal Particulate Class I
EPA Est. No. 002623-IL-002
Std. No. 53—Health effects
Chemical Reduction
Lead
Mechanical Filtration
Cyst
CALIFORNIA PROPOSITION 65 WARNING
This product contains chemicals known to the
State of California to cause cancer or birth defects or other reproductive harm.
Reduces particles as small as 0.5 micron in size by mechanical means.
NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by mechanical means.
4EVERPURE SPA-400 Water Filtration System
ENGLISH
EVERPURE SPA-400 Water Filtration System • 5